Troubleshooting Guide; Guarantee And Service - ILVE IVN900X General Manual

Table of Contents

Advertisement

Problem
Hood doesn't turn on.
Poor Airflow
Hood is vibrating
Motor running but no
air flow
Motor stops after a few
minutes
Strong cooking smell.
Oil dripping onto
stove.
Whirring sound
Lights are working but
fan isn't
Fan is working but
lights are not

GUARANTEE AND SERVICE!

Before booking a service call, read the Trouble Shooting Guide above , for more information
on guarantee and service conditions, please contact local dealer.
Trouble Shooting Guide
Possible Reason
No electrical supply.
Power cord is damaged
Aluminum grease filters clogged
Charcoal filters clogged.
Re-circulating mode only.
Hood is not secured in place
Butterfly valve jammed.
High temperature safety device
activated.
The hood is installed too near the
cooking surface.
Fan speed too low
Charcoal filters not installed.
Aluminum grease filter
satu-rated.
Something in contact with fan
blade.
Check the plug is connect-ed.
Check the plug is connect-ed.
Contact technician service
Clean the filters and replace
when dry.
Replace the charcoal filters.
Check the installation of hood.
Tighten mounting screws.
Contact technician service
The kitchen is not sufficiently
ventilated.
The hood must be at least
650mm from the stove
Use one of the higher set-tings.
In re-circulating mode,
char-coal filters must be
installed.
Wash the aluminum grease
filters
Contact technician service
Contact technician service
Contact technician service
13
Solution

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ivn900nIvcc900xIvg901xIvcg900Ivsg900

Table of Contents