A
Minimum distances
Dimension
A
3.3 Levelling of the appliance
Use small feet on the bottom of appliance to
set the appliance top surface level with other
surfaces.
3.4 Electrical installation
WARNING!
The manufacturer is not responsible if
you do not follow the safety precautions
from Safety chapters.
This appliance is supplied without a main
plug or a main cable.
Applicable types of cables for different
phases:
Phase
1
3 with neutral
8
ENGLISH
mm
650
Min. size cable
3x6.0 mm²
5x1.5 mm²
WARNING!
The power cable must not touch the part
of the appliance shaded in the illustration.
3.5 Covering terminal board
• The recommended cross-section area is
six square millimetres (6 mm²).
• When you refit the mains terminal cover,
make sure that the lower tabs are located
inside the bottom edge of the aperture,
before you fix the two screws into the top
edge of the mains terminal cover.
• Make sure that the cover is securely
fastened.
To open the cover of terminal board obey
the procedure in opposite sequence.
3.6 Terminal board
Do not remove blanking plates.
Make sure that the links are fitted as shown.