Clearances - Drolet DECO II Installation And Operation Manual

Table of Contents

Advertisement

8.1

Clearances

APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
14 ½" (368 mm)
A
B
16" (406 mm)
C
12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
25" (635 mm)
F
20 ¾" (527 mm)
8.1.1
With Heat Shield AC02762
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
3" (76 mm)
B
5" (127 mm)
C
3" (76 mm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double
wall pipe connector can be used.
Installation and Operation Manual - Drolet Deco II
USA
13" (330 mm)
15" (381 mm)
12" (305 mm)
FROM PIPE CONNECTOR
USA
16 ½" (419 mm)
24" (610 mm)
20 ¾" (527 mm)
14
USA
3" (76 mm)
5" (127 mm)
3" (76 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
7 ½" (191 mm)
B
16" (406 mm)
C
12" (305 mm)
DISTANCES
FROM PIPE CONNECTOR
13
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
11 ½" (292 mm)
E
25" (635 mm)
F
20 ¾" (527 mm)
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
D
6 ½" (165 mm)
E
14" (356 mm)
F
11 ¾" (298 mm)
USA
7 ½" (191 mm)
15" (381 mm)
12" (305 mm)
USA
11 ½" (292 mm)
24" (610 mm)
20 ¾" (527 mm)
USA
6 ½" (165 mm)
14" (356 mm)
11 ¾" (298 mm)
Page 31