(2) Functions available when setting the unit number to 01–03 or AL (07 in case of wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number of Operating Procedure.
• When setting functions for a simultaneous- Twin Triple indoor unit system, set the unit number to 01 to 03 for each indoor
unit in case of selecting different functions for each unit referring to 4 setting the indoor unit number of Operating Procedure.
• When setting the same functions for an entire simultaneous Twin Triple-indoor unit system, set refrigerant address to AL (07
in case of wireless remote controller) referring to 4 setting the indoor unit number of Operating Procedure.
Function
Filter sign
100 h
2500 h
No filter sign indicator
Air flow
Quiet
(Fan speed)
Standard
High ceiling
No. of air outlets
4 directions
3 directions
2 directions
Optional high efficiency
Not supported
filter
Supported
Vane setting
No vanes (Vane No. 3 setting: PLA only)
Vane No.1 setting
Vane No.2 setting
Position 1 ("□" stamp position)
3D i-see Sensor
positioning
(Position 2)
Position 3 ("□" stamp position)
Optional humidifier
Not supported
(PLA only)
Supported
Vane differential setting
No.1 setting (TH5: 24–28:)
in heating mode
No.2 setting (Standard, TH5: 28–32:)
(cold wind prevention)
No.3 setting (TH5: 32–38:)
Swing
Not available Swing
Available
Set temperature in heating
Available
mode (4 degree-up)*
Not available
Extra low
Fan speed during the
heating thermo-OFF
Stop
Setting fan speed
3D i-see Sensor ceiling
Low ceiling
height setting
Standard
High ceiling
Fan speed during the
Setting fan speed
cooling thermo-OFF
Stop
Extra low
Detection of abnormality of
Available
the pipe temperature (P8)
Not available
*PKA-HA/KA: 2 degree-up
PEAD-M
JA(L)
Function
Filter sign
100h
2500h
No filter sign indicator
External static pressure 35/50/70/100/150Pa
External static pressure 35/50/70/100/150Pa
Set temperature in heating
Available
mode ( 4 degree-up )
Not available
Fan speed during the
Extra low
heating thermo OFF
Stop
Set fan speed
Fan speed during the
Set fan speed
cooling thermo OFF
Stop
Available
Detection of abnormality
Not available
of the pipe
Mode No.11
Setting No.
Settings
Vane No.3 setting
1
No Vanes
2
Vane No.1 setting
3
Vane No.2 setting
* Be careful of the smudge on ceiling.
OCH679A
Mode
Setting
Settings
No.
No.
1
07
2
3
1
08
2
3
1
09
2
3
1
10
2
1
11
2
3
1
12
2
3
1
13
2
1
14
2
3
}
1
23
PLA-EA
Wave air flow
2
1
24
2
1
25
2
3
1
26
2
3
1
27
2
3
1
28
2
Setting
Mode
Settings
No.
No.
07
08
Refer to the right table
10
24
25
27
28
PLA-RP ・ EA
Less smudging
( Downward position than the standard )
Standard
Less draft * (Upward position than the standard) Less draft * (Upward position than the standard)
Initial setting (factory setting)
4-way
Ceiling suspended
cassette
PLA-RP•EA PCA-HAQ PCA-M•KA PKA-M•HA(L) PKA-M•KA(L)
: Initial setting
External static
( Factory setting )
pressure
35Pa
1
2
50Pa
3
70Pa
100Pa
Refer to the right table
150Pa
1
2
1
2
3
1
2
1
2
No vane function
Standard
75
─: Not available
Floor
Wall mounted
standing
PSA-KA
Setting No.
Initial setting
( Factory setting )
Mode No. 08 Mode No. 10
2
1
3
1
2
1
2
2
3
2
PCA-M ・ KA
Ceiling
concealed
PEA-WKA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pu-p250yka3Puhz-p200yka3.ukPuhz-p250yka3.uk

Table of Contents