1.3. Indoor capacity range

1.3.1.
Connection Ratio
Connection Ratio = Total capacity index of the indoor units / Capac-
ity index of the outdoor units
Type
Types of connected outdoor units
6 - 14 ton
Single outdoor unit
16 - 20 ton
Double outdoor units
Types of connected indoor units
Type
When using only
FXDQ, FXMQ-PB,
FXAQ, FXSQ07-54T
Single
6 - 14 ton
outdoor
16 - 20 ton
200% *1
unit
Double outdoor units
Types of connected air treatment
Type
When FXMQ-MF is
only connected
Single
6 - 14 ton
outdoor
16 - 20 ton
100%
unit
Double outdoor units
Notes: *1. If the operational capacity of indoor units is more than
130%, low airflow operation is enforced in all the indoor
units. This limitation can be abolished through field setting.
*2. When outdoor-air processing units (FXMQ-MF) and
standard indoor units are connected, the total connection
capacity of the outdoor-air processing units (FXMQ-MF)
must not exceed 30% of the capacity index of the outdoor
units. And the connection ratio must not exceed 100%.
*3. When connecting the hydrobox, to prevent temporary
water temperature drop on the secondary side of the
hydrobox at the time of defrosting or when the indoor unit
starts/stops, and to prevent freezing, connect the indoor
unit with 50% or more capacity of the outdoor unit.
1.3.2. Outdoor Unit Combinations
Total capacity of indoor units needs to be within the specified range.
RXYQ-A type
<Outdoor unit>
<Total capacity index of indoor units>
RXYQ72AATJ*/AAYD*
RXYQ96AATJ*/AAYD*
RXYQ120AATJ*/AAYD*
RXYQ144AATJ*/AAYD*
RXYQ168AATJ*/AAYD*
RXYQ192AATJ*/AAYD*
RXYQ216AATJ*/AAYD*
RXYQ240AATJ*/AAYD*
RXYQ264AATJ*/AAYD*
RXYQ288AATJ*/AAYD*
RXYQ312AATJ*/AAYD*
RXYQ336AATJ*/AAYD*
RXYQ360AATJ*/AAYD*
RXYQ384AATJ*/AAYD*
RXYQ408AATJ*/AAYD*
RXYQ432AATJ*/AAYD*
RXYQ456AATJ*/AAYD*
RXYQ480AATJ*/AAYD*
3
Min. connection ratio
RXYQ-A type
50%
Max. connection ratio
When using at least one
When using other
FXFQ07/09, FXZQ05T,
indoor unit models
FXSQ05T
180% *1
200% *1
180% *1
180% *1
160% *1
160% *1
Max. connection ratio
Low-temperature
hydrobox
When FXMQ-MF
When HXY48T and
and indoor units are
indoor units are
connected
connected
100% *2
130% *3
. . . . . . . . . . . .
36-93
. . . . . . . . . . . . 48-124
. . . . . . . . . . . . 60-156
. . . . . . . . . . . . 72-187
. . . . . . . . . . . . 84-218
. . . . . . . . . . . . 96-249
. . . . . . . . . . . . 108-280
. . . . . . . . . . . . 120-312
. . . . . . . . . . . . 132-343
. . . . . . . . . . . . 144-374
. . . . . . . . . . . . 156-405
. . . . . . . . . . . . 168-436
. . . . . . . . . . . . 180-468
. . . . . . . . . . . . 192-499
. . . . . . . . . . . . 204-530
. . . . . . . . . . . . 216-561
. . . . . . . . . . . . 228-592
. . . . . . . . . . . . 240-624
NOTE
Higher capacity than the table 1.3.2 can be selected, this may affect
heating and cooling capacity. For additional information see technical
engineering data.

1.4. Scope of the manual

This manual describes the procedures for handling, installing and
connecting the VRV RXYQ-A series outdoor units. This manual has
been prepared to ensure adequate maintenance of the unit, and it will
provide help in case problems occur.
INFORMATION
The installation of the indoor unit(s) is described in the indoor unit
installation manual provided with the indoor unit(s).

2. Accessories

2.1. Accessories supplied with this unit

Confirm the following accessories are included. The storage location
of the accessories is shown in the figure below.
Accessories assy
(operation and installation manual)
NOTE
Do not throw away any of the accessories until installation is complete.
They are needed for installation work.
Name
Clamp
Manuals, etc.
Quantity
7 pcs.
• Operation Manual
• Installation Manual
Shape
• REQUEST FOR THE INDICATION label
(Installation records)
Liquid side
Liquid side
Name
accessory
accessory
pipe (1)
pipe (2)
Quantity
1 pc.
1 pc.
Shape
96A
Accessories assy (piping)
L type
accessory joint
1 pc.
1 pc. each
Gas side
Gas side
accessory
accessory
pipe (1)
pipe (2)
1 pc.
1 pc.
168A
72, 96A 120,144A 168-240A
72A 96A 120,144A 240A
English

Advertisement

Table of Contents
loading

Table of Contents