Page 4
www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
Page 7
Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
Page 8
www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could hoods mounted too high will be hard to reach and If available, also refer range manufacturer’s height i n .
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use single wall rigid metal ductwork only. Some Ducting Options AK9228AS & AK9234AS Models Only side wall cap w/ gravity damper...
Page 10
www.zephyronline.com Front (28”)14- ” (34“)17- ” (40”)20- ” (46“)23- ” (28”)9- ” (34“)12- ” (28”, 34”) (40”)15- ” ” (46“)18- ” (40”, 46”) ” elec. ” ” Back * Dimensions for 28” and 34” model sizes only...
ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
Page 12
www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the liner. If possible, power up and test all functions prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel. 2.
2. Remove grease tray by: 1) Pulling up on tray to release from bottom panel. 2) Lifting tray out of front of liner. 2) liner body. Bottom Panel Screws Locking Tabs 4. Remove bottom panel by: 1) screws from left and right sides of bottom panel. 2) Pulling bottom panel toward front of liner to panel.
Page 14
www.zephyronline.com AK9228AS and AK9234AS Models Only 2. Remove grease tray by: 1) Pulling up on tray to release from bottom panel. 2) Lifting tray out of front of liner. 2) liner body. Bottom Panel Screws Locking Tabs 4. Remove bottom panel by: 1) screws from left and right sides of bottom panel.
Page 15
AK9228AS and AK9234AS Models Only Rect. ducting Round ducting 8. Remove knock-outs A and B for rectangular ducting. Remove knock outs B and C for round or 3 1/4”x10” rect. knock-out plates at the back ducting. of the liner. At this point, install the one piece liner into the cabinet by following the steps on Page 10, Step 4.
www.zephyronline.com AK9228AS and AK9234AS Models Only 10. (Rectangular Ducting) From inside the liner, 10. (Round Ducting) From inside the liner, push push 3-1/4” x 10” rectangular adaptor through 8” round adaptor through the back knock-out the back knock-out and secure to interior back M4 x 6mm screws.
Page 17
Blower On/Off Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. ACT Verification - Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations.
Page 18
www.zephyronline.com Baffle Filter Clean Reminder Aa set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle- Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use.
Page 19
The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 4. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
Page 20
www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser.
Page 21
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. use a rubber/latex glove and turn counter clockwise. For Zephyr part numbers please turn to page 26 of the manual. Bottom View...
Page 22
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. levels; AK9228AS & AK9234AS - 290 or 390 CFM, AK9240AS & AK9446AS - 590 or 390 CFM. The usage of ACT may not be necessary for your installation.
Page 23
AK9228AS and AK9234AS Models Only MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK9228AS, AK9234AS CIRCUIT DIAGRAM ACT 390 CFM - Fan Max. 355W @ 3.0A ACT 290 CFM - Fan Max. 255W @ 2.4A...
Page 25
AK9240AS and AK9246AS Models Only ACT 590 CFM - Fan Max. 556W @ 4.6A ACT 390 CFM - Fan Max. 381W @ 3.4A...
Page 26
www.zephyronline.com AK9240AS and AK9246AS Models Only...
Page 27
TROUBLESHOOTING PROCEDURES FOR MONSOON I Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
www.zephyronline.com DESCRIPTION PART # Replacement Parts RF Remote Control 14000005 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
Page 29
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
Need help?
Do you have a question about the ESSENTIALS Monsoon I AK9240AS and is the answer not in the manual?
Questions and answers