VOLTCRAFT DDS-3025USB User Manual
VOLTCRAFT DDS-3025USB User Manual

VOLTCRAFT DDS-3025USB User Manual

Arbitrary function generator
Hide thumbs Also See for DDS-3025USB:

Advertisement

Quick Links

User's Manual
DDS-3025USB
ARBITRARY FUNCTION GENERATOR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DDS-3025USB and is the answer not in the manual?

Questions and answers

Summary of Contents for VOLTCRAFT DDS-3025USB

  • Page 1 User’s Manual DDS-3025USB ARBITRARY FUNCTION GENERATOR...
  • Page 2: Table Of Contents

    Content General safety summary ......................1 Introduction ..........................2 Chapter 1 Getting started ......................4 1.1 System Requirements ....................5 1.2 Installing Hardware ....................6 1.3 Installing Software ..................... 9 Chapter 2 Operating Basics ....................12 2.1 The User’s Interface ....................13 2.2 The Menu System ....................
  • Page 3: General Safety Summary

    DDS-3025 USB General safety summary Please understand the following safety precautions to avoid injuries and damages to the product or any equipment connected. To be away from possible dangers, please be sure to follow the regulations.  Only qualified persons are allowed to do the maintenance. ...
  • Page 4: Introduction

    Saw-tooth, TTL, White Noise, Gauss Noise, Trapeze, Exponent, AM and FM. The parameters, such as amplitude, frequency and offset, are also settable. The data format of DDS-3025USB is completely compatible with that of Tektronix; it can directly read the waveform data files produced by the Tektronix oscilloscope or Tektronix waveform editor software and redisplay the waveform.
  • Page 5 DDS-3025 USB Panel introduction Control Pin Digital Out Pins Synchronized OUTPUT Counter/Frequency Digital IN Pins Signal Output Inputs USB Port USBXI Port External Trigger USER’S MANUAL...
  • Page 6: Chapter 1 Getting Started

    DDS-3025 USB Chapter 1 Getting started This chapter focuses on the following topics:  System Requirements  Installing hardware  Installing software USER’S MANUAL...
  • Page 7: System Requirements

    DDS-3025 USB 1.1 System Requirements  Minimum System Requirements Operating System Windows XP/Vista/Win 7/Win8 Memory 128MB Graphic Card Microsoft DirectX supported Screen resolution: 1024x768 Color depth: 16bit  Recommended System Requirements Operating System Windows XP/Vista/Win 7/Win 8 Memory 256MB Graphic Card Microsoft DirectX supported Screen resolution: 1024x768 Color depth: 16bit...
  • Page 8: Installing Hardware

    DDS-3025 USB 1.2 Installing Hardware Connect the A-Type Plug of USB cable to your PC’s USB port. Connect the B-Type Plug of USB cable to the device’s USB port. New hardware is found. New hardware search wizard starts. USER’S MANUAL...
  • Page 9 DDS-3025 USB Choose the correct directory of the driver through the browser or search in the CD driver. New hardware wizard installs software. USER’S MANUAL...
  • Page 10 DDS-3025 USB Finish new hardware search wizard. USER’S MANUAL...
  • Page 11: Installing Software

    1. While in Windows, insert the installation CD into the CD-ROM drive. 2. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run "Setup.exe". 3. The DDS-3025USB Installation is started. Click 'Next' to continue. USER’S MANUAL...
  • Page 12 DDS-3025 USB 4. Choose a destination directory. Click 'Next' to continue. 5. Check the setup information. Click Next to start copying of files. USER’S MANUAL...
  • Page 13 DDS-3025 USB 6. This Status dialog is displayed during copying of files. 7. The installation is complete. USER’S MANUAL...
  • Page 14: Chapter 2 Operating Basics

    DDS-3025 USB Chapter 2 Operating Basics This chapter focuses on the following topics:  The User’s Interface  The Menu System  The Waveform Control System USER’S MANUAL...
  • Page 15: The User's Interface

    DDS-3025 USB 2.1 The User’s Interface DDS-3025USB provides users a simple and full-featured interface so that users do not have to spend a lot of time to learn. USER’S MANUAL...
  • Page 16: The Menu System

    Print the current waveform  Print Preview: Preview the current waveform  Print Setup: Configure the print setup  Exit: Exit DDS-3025USB Edit  Points Edit: Draw the waveform after click the command of Arb.  Zoom In: Zoom in the waveform. ...
  • Page 17 DDS-3025 USB Wave Parameter  Square: Show square waveform.  Ramp: Show ramp waveform.  Trapezia: Show trapezia waveform.  Exponent: Show exponent waveform.  AM/FM: Show AM/FM waveform. Digital IO  Pattern Generator: Set the Digital out pin as pattern generator. ...
  • Page 18  Sweep: Show the sweep dialog.  Open Output Power On: Save the current waveform to DDS-3025USB, and generate the waveform when the DDS-3025USB powers on.  Close Output Power On: Stop generates the waveform when the DDS-3025USB powers on.
  • Page 19: The Waveform Control System

    DDS-3025 USB 2.3 The Waveform Control System Click Menu “Display”->”Show/Hide control”, you can show or hide the waveform control panel. You can change the waveform parameter such as frequency, amplitude, Y Offset, or phase. Also, it includes the frequency/counter measurement system. USER’S MANUAL...
  • Page 20: Chapter 3 Understanding Functions

    DDS-3025 USB Chapter 3 Understanding Functions This chapter focuses on the following topics:  Waveform parameter  Waveform output control  Edition of Arbitrary Waveform  Counter/Frequency Measurement  Waveform data files  Digital Input/Output  Output Power On  Synchronized Output ...
  • Page 21: Waveform Parameter

    DDS-3025 USB 3.1 Waveform parameter Choose waveform Press down any button of certain waveform to switch to the output of such kind of waveform. When switch to arbitrary waveform from other kind of waveform, the edition work can be done on the original wave form. Set waveform parameters Click Menu “Wave Parameter”, there are the choices for setting of various waveform parameters.
  • Page 22: Waveform Output Control

    DDS-3025 USB 3.2 Waveform Output Control By the following buttons to control the output dot numbers, trigger mode, output amplitude, and limit frequency of the wave filter. Single Wave: Output waveform only once. -20dB: Attenuation the waveform Ext Trig: Use the external or internal trigger system. Wave ON/OFF: Turn the waveform on/off.
  • Page 23: Edition Of Arbitrary Waveform

    DDS-3025 USB 3.3 Edition of Arbitrary Waveform Choose “Arb” waveform, and click the menu”Edit”->”Edit Points” to open edit points dialog. USER’S MANUAL...
  • Page 24: Waveform Data Files

    DDS-3025 USB 3.4 Waveform Data Files The data format of DDS-3025USB is “.CSV”. Its format is compatible with the CSV file produced by the Tektronix ARB Express software. User can edit or set up the required CSV waveform and also use Excel to open and edit the CSV wave files.
  • Page 25: Frequency/Counter Measurement

    DDS-3025 USB 3.5 Frequency/Counter Measurement Click the “F/C ON/OFF” to turn on or off the frequency/counter measurement. Connect to the Frequency/Counter Measurement terminal, and turn on the “F/C ON/OFF”, you can see the frequency in the edit box. Turn the left right button to “C” end, you can see the counter in the edit box. USER’S MANUAL...
  • Page 26: Digital Input/Output

    3.6 Digital Input/Output Select Menu “Digital IO”, you can change the current digital IO mode. At the digital IO terminal on the DDS-3025USB, there are 20 digital IO pins, 3 GND, 1 CTRL, 4 Digital In Pins and 12 Digital Out Pins.
  • Page 27 DDS-3025 USB 2. Programmable Output: Select menu “Programmable output”, then the Programmable output mode works. Select menu “Digital IO”->”Output set”, the “output set” dialog show. USER’S MANUAL...
  • Page 28 DDS-3025 USB By selecting one pin, that digital output pin will output high level. Otherwise, the pin will output low level. 3. Digital Input Select menu “Digital IO”->”Digital Input”, the following dialog show. If you input a high level to a digital input pin, the pin on the dialog would show H; otherwise, the pin on the dialog would show L.
  • Page 29: Output Without Pc

    DDS-3025 USB 3.7 Output without PC DDS-3025USB can save a waveform to its own memory and work without PC. Open: Select menu “Utility” -> “Open output power on”. Then the current waveform will be saved to hardware. And the waveform will be generated every time when you connect the DDS- 3025USB to power.
  • Page 30: Synchronized Output

    DDS-3025 USB 3.8 Synchronized output If you generate a waveform by software, there is a synchronized signal output from “SYNC” terminal. The signal is square waveform, the frequency of which is equal to the waveform you generated. For example, if you generated a 1 KHz, sine waveform, you will also generate an 1 KHz, square waveform simultaneously.
  • Page 31: External Trigger Input

    DDS-3025 USB 3.9 External Trigger Input Also, you can use the external trigger input to control the DDS-3025USB. For example, the instrument generated a waveform, and you got a waveform on oscilloscope. Then, click the “Ext Trig” button on the interface of the software. The waveform on the oscillograph disappeared.
  • Page 32 Click the “Ext Trig” mode to switch the external trigger mode between “Fall” and “Rise”. Select the Fall mode as example. Input a signal which has fall edges to the “TRIGIN” BNC terminal. When the DDS-3025USB gets to the fall edge of the external signal, it begins to generate waveform.
  • Page 33: Chapter 4 Application Examples

    DDS-3025 USB Chapter 4 Application Examples This chapter focuses on the following topics:  Generate the simple waveform  Generate Arbitrary Waveform USER’S MANUAL...
  • Page 34: Generate The Simple Waveform

    DDS-3025 USB 4.1 Generate the Simple Waveform To generate a simple waveform, please do these steps as follows: Open the software. Choose the waveform type in the right control panel. Move your mouse to the waveform screen. Press the mouse left button and move, draw your own waveform. Then you can see your own waveform in the oscilloscope.
  • Page 35: Generate Arbitrary Waveform

    DDS-3025 USB 4.2 Generate Arbitrary Waveform To generate a arbitrary waveform, please do these steps as follows: Open the software. Choose the “Arb” waveform in the right control panel. Move your mouse to the waveform screen. Press the mouse left button and move, draw your own waveform. Then you can see your own waveform in the oscilloscope.
  • Page 36: Appendix

    DDS-3025 USB Appendix  Hardware specification  Cleaning and Maintenance USER’S MANUAL...
  • Page 37: Hardware Specification

    DDS-3025 USB Hardware Specification Waveform Output Channel sine: 1Hz(DC)~50MHz Ramp: 1Hz ~ 10MHz Trapezia: 1Hz ~ 10MHz Exponent: 1Hz ~ 10KHz Frequency Range Square: 1Hz ~ 5MHz Arb: 1Hz ~ 25MHz GauseNoise: 1Hz ~ 5MHz AM/FM: 1Hz ~ 10MHz WhiteNoise: 1Hz ~ 5MHz Frequency Resolution 0.1%...
  • Page 38 DDS-3025 USB 0˚C~+40˚C Operating Temperature Storage Temperature -20˚C~+60˚C Working Humidity 0~95% Weight 400g USER’S MANUAL...
  • Page 39: Cleaning And Maintenance

    DDS-3025 USB Cleaning and maintenance Cleaning n order to maintain the cleanliness of equipment, you need to check whether the channels are dusty or not. Please clean the out surface of the equipment follow these matters. Use velvet cloth contact the surface of the equipment. Pease do not use any corrosive or chemistry.

Table of Contents