5. Electrical supply and electrical
connection
Electrical supply to the unit must be nominal
230VAC 50~Hz.
Electrical connection to the product is via a 3 way
terminal block inside the product (L, N, E), on
electrical panel.
Connect the power supply from the fused spur (3
Amp) to the heater terminal block marked Supply
E N L via the cable entry hole in the top chassis of
the heater.
The fused spur must not be directly below the
heater and must be accessible after the installation
is complete.
All electrical work should be carried out in
accordance with current IEEE regulations.
N
L
Supply
3 Amp
fused spur
Installation -
Remote smart controller
For Smart flush and integral control models
continue to page 16.
1. Ensure power supply is switched off
2. Remove the mounting plate from the controller
by inserting a small screwdriver into slots at
base of controller. See Fig 2.
3. Fix the mounting plate to the wall using either
a recessed or surface mounted back box using
the screws provided. See fig 3.
4. Connect power supply, connect wires into the
appropriate terminals on the controller.
See Fig 4.
5. Fasten body of thermostat and the mounting
plate. See Fig 5.
6. When using external pattress box assemble as
shown. See Fig 6.
87
44
87
56
ON
OFF ON
OFF
OFF
OR
ON
Fig. 1
UP
60
Fig. 3
Fig. 5
Issue 001 - October 2023 | SmithsEP.co.uk | 11
17
47
30
S2 COM S1
SALUS
FC600
50
F3 F2 F1 V2 V1 N L
60
Fig. 2
SALUS
S2
COM
S1
FC600
F3 F2 F1 V2 V1 N L
Fig. 4
Fig. 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smith's caspian ct60ffSmith's caspian ct120ff

Table of Contents