Contents Declaration of conformity Introduction EC Declaration of conformity Declaration of conformity We, Smith’s Environmental Products Limited 1-2 Blackall Industrial Estate Symbols used in this guide South Woodham Ferrers Important safety and installation instructions 3/4 Chelmsford Application Essex CM3 5UW Tel: 01245 324900 Fax: 01245 324422 Product Information Declare under sole responsibility that the products:...
Symbols This manual contains information and prescriptions marked by the following symbols: Ignoring these safety High temperature Ignoring these safety provisions marked by surface. provisions marked by the symbol “caution: Take utmost care the symbol “caution: electricity” may to prevent people hazard”...
Important safety and installation instructions Prior to installation, read these installation and operating instructions. The installation and operation should also be in accordance with national regulations and accepted codes of good practice. 6. Electrical connection IMPORTANT: Connection to the power supply must be effected by means of a fixed power cable which is fitted with a plug-type connection or a two pole isolating switch with a minimum contact opening of 3 mm.
Product dimensions and performance SS2E SS80E Heat output Power Heat output Heat Output Fused Mains Cable Consumption (kW) spur (kW) Power Heat Output Fused Mains Cable 0.6kW/1.2kW 0.6kW/1.2kW Consumption (kW) spur (kW) 1kW/2kW 1kW/2kW Voltage: 230V SS3E LED lens 100* *Overall height inc.
Page 6
Product dimensions and performance WALL CONTROLLER SS5 DUAL Pattress Pipe centres Heat output - electric mode Power Heat Output Fused Mains Cable Consumption (kW) spur (kW) Heat output - hydronic mode It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (l) enabling the boost setting (ll) to be used for faster heat up.
Installation - Heater 2a. Connection for SS5 Dual Heater - Fit isolating valves 1. Cut the opening in the plinth (not supplied) • To ensure adequate airflow, a minimum clearance of 20mm (10mm for SS80E product) between the top of the product and any shelving is essential •...
5. Overlay grille (optional) 2c. Electrical connection - Heater • Isolate the electrical supply and connect the heater electric cable to the fused spur • The fused spur must not be directly above the heater, but should be accessible after completion of the installation •...
Page 9
• Run-back Timer This can be used to limit the run time of the heater from between 5 minutes and 2 hours The Run-back Timer cannot used be used in conjunction with Temperature control for Setback (SETB). 1. Choosing a position in a room for the wall controller The Controller should be positioned 1.5m above the floor and in the same room/space as the heater.
Thermostat Controller - controller not pairing and pairing process should be restarted from step 3 Quick Set up 5. To exit the pairing mode, press the ON/OFF button on the IMPORTANT – THIS HEATER WILL NOT WORK SLVTB thermostat controller UNLESS USED AND PAIRED WITH THE SLVTB ONCE (DO NOT HOLD THE THERMOSTAT CONTROLLER...
Commissioning SS2E SS3E 1. Before switching the heater on, please ensure 1. Before switching the heater on, please ensure the fascia grille is free from obstruction the fascia grille is free from obstruction 2. Ensure your fused spur is switched ON 2.
Page 13
SS80E SS5 DUAL 1. Before switching the heater on, please ensure 1. Before switching the heater on, please ensure the fascia grille is free from obstruction the fascia grille is free from obstruction 2. Ensure your fused spur is switched ON 2.
Installation - with 2. Temperature control for Comfort (COMF) advanced features Switch 1 controls the display screen. If it is set to 1. Getting to know your ’ON’ the temperature is displayed as Fahrenheit. battery controller If it is set to ‘OFF’ the temperature is displayed as Celsius.
Page 15
3. Temperature control for In timer mode, switch 3 or 4 must be in the ‘ON’ position. This mode allows for 3 different settings Setback (SETB) which will alter the time period for each segment. Switch 3 - Each time period represents 5 minutes For this mode, the switches are set as shown below.
Commissioning - see page 12 Fault finding In the event of any difficulty, please contact us on +44 (0) 1245 324560. Fault Checking/Solution Check the power supply is switched ON Check fuse in fused spur Check the fan switch is set to ON Fan does not run/no heat output Check the battery in the controller and replace if necessary Check the wireless controller thermostat is calling for heat...
Important safety and installation instructions Please read this user manual before operating this appliance. The operation should also be in accordance with national regulations and accepted codes of good practice. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
How it works - Heater • Run-back Timer This can be used to limit the run time of the heater from between 5 minutes and 2 hours Cooler air is drawn in by the fan and heated as it passes through the heating element before being The Run-back Timer cannot used be used in discharged gently back into the room.
How to operate SS2E Basic setting enabled Temperature control for Comfort (COMF) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON 3. Switch the upper fan switch to ON 2.
Page 21
SS2E Temperature control for Comfort How to operate – Run back Timer (COMF) and Temperature control mode enabled for Setback (SETB) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON 3.
Page 22
How to operate SS3E Basic setting enabled Temperature control for Comfort (COMF) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON 3. Ensure the wireless controller is paired 2.
Page 23
SS3E Temperature control for Comfort How to operate – Run back Timer (COMF) and Temperature control mode enabled for Setback (SETB) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON. 3.
Page 24
How to operate SS80E Basic setting enabled Temperature control for Comfort (COMF) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON 3. Ensure the wireless controller is paired 2.
Page 25
SS80E Temperature control for Comfort How to operate – Run back Timer (COMF) and Temperature control mode enabled for Setback (SETB) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON 3.
Page 26
How to operate SS5 DUAL Basic setting enabled Temperature control for Comfort (COMF) enabled 1. Set the upper rocker switch on the fascia grille to the right (blue) and the lower switch to the 1. Ensure your fused spur is switched ON left or right - the fan should run 2.
Page 27
SS5 DUAL Temperature control for Comfort How to operate – Run back Timer (COMF) and Temperature control mode enabled for Setback (SETB) enabled 1. Ensure your fused spur is switched ON 2. Ensure the wireless controller is switched ON 1. Ensure your fused spur is switched ON 3.
Fault finding This Space Saver is covered by a free 5-year parts and labour guarantee. Please refer to the Fault finding table below for advice. In the event of difficulty, please contact us on +44 (0) 1245 324560. Fault Checking/Solution Check the power supply is switched ON Check fuse in fused spur Check the fan switch is set to ON...
Registering your product Disposal As part of the policy of continuous product Thank you for purchasing a Smith’s product. It has improvement, Smith’s Environmental Products LTD been designed and manufactured to the highest reserves the right to alter specification without quality standards to ensure it gives you efficient prior notice.
Page 32
Happy to help To view the full product information download the datasheet at: Smith’s Environmental Products Ltd is one of the leading manufacturers of heating and cooling www.SmithsEP.co.uk products in the UK. We are committed to achieving the highest standards and our faith is For product information, customer services or supported by a free parts and labour guarantee sales support call us on +44 (0) 1245 324900...