Download Print this page

Installation Instructions; Local Menu - Desisti SOFT LED 1 XL Instruction Manual

120w led softlight 90-250v 50/60 hz

Advertisement

C. Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire weight.
D. In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting.
E. A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet
at the front of the body
F. WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE

5. INSTALLATION INSTRUCTIONS

The following procedure should be adopted:
Before connecting the luminaire to the electrical mains ensure that:
A.
Earth line is present on the power socket.
B.
The mains voltage is within the rated range of the luminaire (see technical data on the rating label)
C.
The front safety Shield is present and in good condition.
It consists of a Remote Phosphors Panel 305 x 107 mm.
WARNINGS :
Do not operate the product if the ambient temperature exceeds 40° C
Provide a minimum clearance of 0,1m (4 in.) around fans and air vents.
SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME VISIBLY DAMAGED TO SUCH
AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES.
THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD
D.
Applying power:
Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment:
1 : Neutral 2 : Live Green/Yellow : Ground - This fixture must be connected to ground.
Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on.
Stand Alone operation:
E.
Using the navigation buttons and display readout ( refer to the "Local Menu" chapter )
navigate to Manual and set the desired intensity (for additional operations see "Local Menu" chapter)
F.
DMX operation:
Connect a DMX cable
Navigate to Address mode (Addr) and set the desired address, (refer to the "Local Menu" chapter).
Connect to DMX controller (refer to the "Channel Setting" in the "Local Menu" chapter) and Use it.

6. LOCAL MENU

DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE:
The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the LED FRESNEL. The unit is provided with
a USER MENU accessible instantly on the product.
The unit has also a SERVICE MENU that is only accessible through a PASSWORD and is reserved for QUALIFIED and TRAINED PERSONNEL:
This Manual is applicable to Soft LED1 XL
ILT ITALY srl
Via Cancelliera, 10/a
00041 Albano Laziale (Rome) Italy
tel. +39 06-902901 fax +39 06-90231051
www.desisti.it
PGM PORT
For Firmware Upgrade
Ù FUNCTION 1
Scrolling UP / Increases value "function key"
ENTER
Select / Confirm
Ú FUNCTION 2
Scrolling DOWN / Decreases value "function key"
Display
When the push button are not used for more than 15 seconds the display
will go OFF. It will go ON again anytime a push button is activated.
DMX Presence
Shows the presence of DMX (LED lit = DMX present)
Revised on June 2020