Removing and Installing the Heatsink

Read the following guidelines before you begin to install the heatsink:
• Always turn off the computer and unplug the power cord from the power outlet before
installing the heatsink to prevent hardware damage.
• Unplug all cables from the power outlets.
• Disconnect all telecommunication cables from their ports.
• Place the system unit on a flat and stable surface.
• Open the system according to the instructions.
WARNING!
Failure to properly turn off the server before you start installing components may cause seri-
ous damage. Do not attempt the procedures described in the following sections unless you
are a qualified service technician.
Follow these instructions to remove the heatsink:
1.
Loosen the four captive screws securing the heatsink to the system.
2.
Lift and remove the heatsink.
• Lock the CPU by using a Torx T20 screwdriver to tighten screw.
• When installing the heatsink to CPU, use a Torx T20 screwdriver to tighten 6 captive nuts in
sequence as 1-6.
• The screw tightening torque: 13.5 ± 0.5 kgf-cm.
• To ensure the system operates properly, make sure the heatsink is seated on the processor
firmly.