Operation Monitoring System Be1 - Man D 2848 LE 401 Operating Instructions Manual

Man marine diesel engines
Table of Contents

Advertisement

For repeated starting turn the key back to OFF.
If the engine is kept idling for long periods it may cool down and thus start to emit white
or blue smoke.
We therefore recommend that you do not let the engine idle for more than 5 minutes.
It is well known that with any internal combustion engine wear is higher during idling.
Idling for longer periods is also an environmental nuisance.
Caution:
Do not overload the engine. Do not exceed the maximum permissible engine tilt.
If faults occur, find their cause immediately and have them eliminated in order to
prevent more serious damage!
Display panel in the engine room. Func-
tions independently of the BE1 operation
monitor and shows analog operating val-
ues from the engine.
During operation the oil pressure in the
engine lubrication system must be moni-
tored. If the monitoring devices register a
drop in the lube oil pressure, switch off the
engine immediately.

Operation monitoring system BE1

Caution:
If an engine / gear box alarm is displayed on the monitoring device, the engine is
to be turned off, i.e. operated at low-pressure at a max. of 1200 rpm.
When following alarms are activated
− engine oil pressure / reduction of lubrication oil pressure
− engine coolant temperature / overheating of engine coolant
− engine charge-air temperature
the engine is to be turned off immediately and the cause of the error properly
remedied, i.e. in a specialist workshop.
Do not put this engine into operation again until the error has been eliminated.
Commissioning and operation
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents