14 - MAINTENANCE
R-454B
Main circuits:
50FF
020
028
Volume (l)
C1: 2,5
C1: 2,5
50FF
052
058
Volume (l)
C1: 6,0 C1: 6,6 C1: 6,6 C1: 6,6 C1: 6,6 C1: 6,6 C1: 7,2
50FC
020
028
Volume (l)
C1: 2,5
C1: 2,5
50FC
052
058
C1: 2,5
C1: 2,5
Volume (l)
C2: 2,5
C2: 2,5
Cooling recovery circuit (optional):
50FF/FC
020
028
CR:
CR:
Volume (l)
1,24
1,24
50FF/FC
052
058
CR:
CR:
Volume (l)
1,24
1,24
Refrigerant
These units are supplied with one of these refrigerants:
■ R-410A: belongs to the A1/A1 group, i.e. with high safety both
in the mix and also in the case of a leak.
■ R-454B: belongs to the A2L group, that is, non-toxic and low
flammability.
Caution: with A2L refrigerant, always use an A2L refrigerant
detector when near the unit.
Important: the type of refrigerant included in the unit can be
consulted on the name plate, see section 4.3.
Periodic check of tightness:
Only qualified personnel must perform a periodic leak testing, in
accordance with the regulation (EC) No. 517/2014.
■ The frequency of checks is no longer related to the refrigerant
charge but to its global warming potential:
Charge kg x GWP = t CO2e
Carbon dioxide equivalency (t CO2e) is a quantity that
describes, for a given mixture and amount of greenhouse gas,
the amount in tonnes of CO
warming potential (GWP).
■ Operators shall ensure that the unit is checked for leaks ad
minima according to the following frequency:
Equivalent charge
Environ. impact
R-410A
(Equiv. tonnes)
2,4
t CO2e < 5
t CO2e 5 to 50
2,4
23,9
t CO2e 50 to 500
t CO2e > 500
239,5
Important: units with A2L refrigerant are always equipped
with a leak detector with infrared sensor. Consult the
chapter "Safety elements".
■ The following table shows the refrigerant charge and CO
equivalent tonnes (t CO2e) for each model:
70
037
040
045
C1: 2,5
C1: 3,4
C1: 3,4
062
070
074
086
037
040
045
C1: 2,5
C1: 3,4
C1: 3,4
062
070
074
086
C1: 2,5
C1: 2,5
C1: 3,4
C1: 3,4
C2: 2,5
C2: 2,5
C2: 3,4
C2: 3,4
037
040
045
CR:
CR:
CR:
1,24
1,24
1,24
062
070
074
086
CR:
CR:
CR:
CR:
1,24
1,72
1,72
1,72
that would have the same global
2
Frequency
(kg)
(months)
With
Without
R-454B
detector
detector
10,8
not subject to revision
10,8
24
108,5
12
1084,6
6
R-410A
Main circuits:
047
50FF
020
Charge
C1: 3,4
C1: 7,3
(kg)
Environ.
093
impact
15,2
(t CO2e)
50FF
052
047
Charge
C1: 9,7 C1: 9,7 C1: 10,0 C1: 17,0 C1: 17,5 C1: 17,5 C1: 18,0
(kg)
C1: 3,4
Environ.
impact
20,3
093
(t CO2e)
C1: 3,4
50FC
020
C2: 3,4
Charge
C1: 8,0 C1: 8,3 C1: 11,0 C1: 11,0 C1: 11,3 C1: 11,6
(kg)
Environ.
impact
16,7
047
(t CO2e)
CR:
1,24
50FC
058
C1: 6,4
Charge
093
(kg)
C2: 6,4
CR:
Environ.
1,72
impact
26,7
(t CO2e)
Additional charge of the optional active dehumidification:
Active dehumidification is equipped with an additional
condensation coil, in series with the main cooling circuit, to reheat
the air. In two-circuit units, the coil is incorporated in circuit 2.
Note: this option is not available for 50FC 099 model.
50FF
020
Charge
C1: 3,3
(kg)
Environ.
impact
6,9
(t CO2e)
50FF
052
Charge
C1:10,5 C1:10,5 C1:10,5 C1:10,5 C1:10,5 C1:10,5 C1:10,5
(kg)
Environ.
impact
21,9
(t CO2e)
50FC
020
Charge
C1: 4,9
(kg)
Environ.
impact
10,2
(t CO2e)
50FC
052
Charge
C2:11,2 C2:11,2 C2:11,2 C2:11,5 C2:11,5 C2:11,5 C2:11,5
(kg)
Environ.
impact
23,4
(t CO2e)
Cooling recovery circuit (optional):
50FF/FC
020
Charge
12
CR: 1,7 CR: 1,7 CR: 2,5 CR: 2,5 CR: 2,5 CR: 2,5 CR: 3,0
(kg)
6
Environ.
impact
3,5
3
(t CO2e)
50FF/FC
058
Charge
CR: 3,0 CR: 3,0 CR: 3,4 CR: 3,4 CR: 3,4 CR: 3,4 CR: 3,4
(kg)
Environ.
impact
6,3
2
(t CO2e)
028
037
040
C1: 7,6
C1: 9,7
C1: 9,7 C1: 10,0 C1: 10,3
15,9
20,3
20,3
058
062
070
074
20,3
20,9
35,5
36,5
028
037
040
045
17,3
23,0
23,0
23,6
062
070
074
086
C1: 6,5
C1: 10,0
C1: 10,2
C1: 10,2
C2: 6,5
C2: 10,0
C2: 10,2
C2: 10,2
27,1
41,8
42,4
42,4
028
037
040
C1: 3,3
C1: 5,4
C1: 5,4
6,9
11,3
11,3
058
062
070
074
21,9
21,9
21,9
21,9
028
037
040
C1: 4,9
C1: 4,6
C1: 4,6
10,2
9,6
9,6
058
062
070
074
23,4
23,4
24,0
24,0
028
037
040
045
3,5
5,2
5,2
5,2
062
070
074
086
6,3
7,1
7,1
7,1
045
047
20,9
21,5
086
093
36,5
37,6
047
052
C1: 6,3
C2: 6,3
24,2
26,1
093
099
C1: 10,3
C1: 11,0
C2: 10,3
C2: 11,4
42,8
42,8
045
047
C1: 5,4
C1: 5,4
11,3
11,3
086
093
21,9
21,9
045
047
C1: 4,6
C1: 4,6
9,6
9,6
086
093
24,0
24,0
047
052
5,2
6,3
093
099
7,1
7,1