Electrical Requirements; Freestanding And Undercounter Installation - Whirlpool  GX900QPPB Use And Care Manual

15-inch undercounter trash compactor with clean touch console use & care guide
Hide thumbs Also See for  GX900QPPB:
Table of Contents

Advertisement

Cutout dimensions
(7.6 cm)
A
24" min.
(61 cm)
A. Grounded electrical outlet must be a minimum of 3" (7.6 cm) away
from surrounding cabinets or nearby walls as shown. It can be
placed either to the left or the right side of the product.
Clearance dimensions
B
A. Leave 6" (15.2 cm) of clearance space to the right side of the
compactor in order to remove the compactor bags.
B. Leave 23" (58.4 cm) of clearance in front of the compactor in order
to fully open or remove the compactor drawer.
4
3" min.
34 " min.
(87 cm)
18" min.
(45.7 cm)
15 " min.
(38.7 cm)
A

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Recommended Grounding Method
This compactor is for use on a single phase, 115-volt, 60 Hz, AC
only, 15- or 20-amp fused and properly grounded circuit and is
equipped with a grounding plug as shown below. It is
recommended that a separate circuit serving only this appliance
be provided.
This compactor must be grounded while in use to reduce the risk
of electric shock. The compactor is equipped with a three-
conductor cord and 3 prong grounding-type plug to fit the proper
grounding-type receptacle. The green (or green and yellow)
conductor in the cord is the grounding wire. Do not connect the
green (or green and yellow) wire to a live terminal.
Freestanding and Undercounter
Installation
NOTE: Proper installation is your responsibility. Make sure you
have everything necessary for correct installation. It is the
personal responsibility and obligation of the customer to contact
a qualified installer to assure that electrical installation meets all
national and local codes and ordinances.
Tools needed
Gather the required tools and parts before starting installation.
Level
Phillips No. 2 screwdriver
Tape measure
Flat-blade screwdriver
IMPORTANT:
Do not grasp control panel to move compactor.
Slide compactor onto cardboard or hardboard before moving
compactor across floor to avoid floor covering damage.
Do not allow the rear frame of the compactor to touch the
floor covering when lifting or moving compactor.
Pliers
" hex head wrench
Scissors
Utility knife

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

 gx900qppq gc900qppq gc900qppb gx900qpps

Table of Contents