ALr
doH
Humidity alarm delay with door open
ALr
EdA
Temperature alarm inhibition after any defrost
ALr
iSn
Interval between sanitizations
ALr
tSn
Sanitization time
oUt
oA1
Relay output oA1 configuration
oUt
oA2
Relay output oA2 configuration
oUt
oA3
Relay output oA3 configuration
oUt
oA4
Relay output oA4 configuration
oUt
AOP
Alarm relay polarity
oUt
LoF
Light output OFF when in stand-by
oUt
LAU
Light output ON after power-on
AoU
2Ao
Analogue output 2 configuration
AoU
2oL
Minimum value for analogue output 2
AoU
2oH
Maximum value for analogue output 2
AoU
2At
Interval with analogue output 2 forced at its maximum value
AoU
MA2
Working mode for analogue output 2
AoU
2on
Analogue output 2 ON (valid if 2Ao=tiM)
AoU
2oF
Analogue output 2 OFF (valid if 2Ao=tiM)
AoU
2AS
Fixed value for analogue output 2 (valid if 2Ao=vAL)
AoU
LL1
Level 1 for analogue output 2
AoU
LL2
Level 2 for analogue output 2
AoU
LL3
Level 3 for analogue output 2
AoU
LL4
Level 4 for analogue output 2
inP
ibt
Base times for digital inputs
inP
i1P
Digital input 1 polarity
inP
i1F
Digital input 1 configuration
inP
did
Digital inputs 1 alarm delay (base time depends on par. ixt)
inP
i2P
Digital input 2 polarity
inP
i2F
Digital input 2 configuration
inP
d2d
Digital inputs 2 alarm delay (base time depends on par. ixt)
inP
i3P
Digital input 3 polarity
inP
i3F
Digital input 3 configuration
inP
d3d
Digital inputs 3 alarm delay (base time depends on par. ixt)
inP
nPS
Number of external pressure switch alarms before stopping the regulation
inP
OdC
Compressor and fan status after door opening
inP
rrd
Regulation restart after door alarm
inP
CLi
Light output activation from door input
inP
LCi
Time with light output forced ON (0=function disabled)
inP
n01
Number of motion detections before activating light output (valid if ixF=EMt)
inP
t01
Time with light output forced ON after motion detection
inP
EMF
Motion sensor stop reading interval after switching off the light output by button or serial command (valid if ixF=EMt)
ES
ErA
Energy saving algorithm
ES
HES
Energy saving mode temperature differential
ES
LdE
Energy saving controls the lights (lights OFF when energy saving is active)
ES
StE
Period to switch from normal mode to energy saving mode (valid if ErA=bAS)
ES
EtS
Period to switch from energy saving mode to normal mode (valid if ErA=bAS)
ES
dS
Open door time to switch from EtS to StE (valid if ErA=bAS)
ES
nES
Number of motion detections before disabling energy saving (valid if ixF=EMt)
Cnt
n1H
Number of activations for relay output oA1 (thousands of)
Cnt
n1L
Number of activations for relay output oA1 (units of)
Cnt
n2H
Number of activations for relay output oA2 (thousands of)
Cnt
n2L
Number of activations for relay output oA2 (units of)
Cnt
n3H
Number of activations for relay output oA3 (thousands of)
Cnt
n3L
Number of activations for relay output oA3 (units of)
Cnt
n4H
Number of activations for relay output oA4 (thousands of)
Cnt
n4L
Number of activations for relay output oA4 (units of)
Cnt
n5H
Number of total activations of digital input 1 (thousands of)
Cnt
n5L
Number of total activations of digital input 1 (units of)
Cnt
n6H
Number of total activations of digital input 2 (thousands of)
Cnt
n6L
Number of total activations of digital input 2 (units of)
Cnt
n7H
Number of total activations of digital input 3 (thousands of)
Cnt
n7L
Number of total activations of digital input 3 (units of)
Cnt
F1H
Number of working hours for relay output oA1 (thousands of)
Cnt
F1L
Number of working hours for relay output oA1 (units of)
Cnt
F2H
Number of working hours for relay output oA2 (thousands of)
Cnt
F2L
Number of working hours for relay output oA2 (units of)
Cnt
F3H
Number of working hours for relay output oA3 (thousands of)
Cnt
F3L
Number of working hours for relay output oA3 (units of)
Cnt
F4H
Number of working hours for relay output oA4 (thousands of)
Cnt
F4L
Number of working hours for relay output oA4 (units of)
Cnt
rSC
Total counters reset
rtC
Hur
Hours
rtC
Min
Minutes
rtC
dAY
Day of the week
rtC
dYM
Day of the month
rtC
Mon
Month
rtC
YAr
Year
rtC
Hd1
First day of weekend
rtC
Hd2
2nd day of weekend
rtC
iLE
Energy saving cycle starting time on working days
0
Pr1
min
30
Pr1
min
00:00 Pr1
ora
00:00 Pr1
ora
CP1
Pr2
FAn
Pr2
dEF
Pr2
HEt
Pr2
CL
Pr2
no
Pr2
no
Pr2
nU
Pr2
0
Pr2
%
100
Pr2
%
5
Pr2
sec
Std
Pr2
0
Pr2
sec
0
Pr2
sec
50
Pr2
%
0
Pr2
%
30
Pr2
%
60
Pr2
%
100
Pr2
%
Min
Pr1
OP
Pr1
nU
Pr1
5
Pr1
min
CL
Pr1
EAL
Pr1
0
Pr1
min
CL
Pr2
nU
Pr2
0
Pr2
min
0
Pr1
FAn
Pr1
no
Pr1
no
Pr1
0
Pr1
min
0
Pr1
0
Pr1
min
0
Pr1
min
nu
Pr1
0.0
Pr1
°F
no
Pr1
00:00 Pr1
ora
00:00 Pr1
ora
5
Pr1
sec
0
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
ora
Pr1
ora
Pr1
ora
Pr1
ora
Pr1
ora
Pr1
ora
Pr1
ora
Pr1
ora
no
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
Pr1
nu
Pr1
nu
Pr1
00:00 Pr1
ora