  • Page 13 retain all screws for later and pay attention to unscrew the fixing screws of the the plastic pin on each screw, screw it until Cut power cables on either side of the front glass side (below) the screw head remove the bumpers unscrew the fixing screws of the side (above) attention! on each side there are 2 cables:...
  • Page 14 cut the LED power supply wires that exit under the tank (left side operator) remove the top supporting screws on both sides Long screw over disconnect the glass side power cable under the worktop and repeat for the other side unscrew the side Short screw from the supports,...
  • Page 15 cut the Strip just before the top block Replace the glass top and screw it to the holes on the sides, making sure to place the long screw above and the short one below screw the new sides on and reconnect the power supply do not go beyond this point with the adhesive...
  • Page 16 reposition at venue the new front use the supplied connectors Screw it to the blocks reassembled on the sides reconnect the front glass power wires to the cables cut before Remount the panelling by following backlinks the instructions to disassemble...
  • Page 21 DIXELL Wizmate 1.3.0.0 File Name:16-UL-Dixell XH78T Date : Model : XH78T Firmware : 0.8 Memo : Group Parameter Description Edit Vis. Level Unit Set Point °F Minimum Set point °F Maximum Set point °F Compressor regulation differential in normal mode °F Compressor regulation differential in energy saving mode °F...
  • Page 22 Differential temperature during any pre-defrost phase °F Defrost output deactivation delay Pre-defrost time Automatic defrost (at the beginning of any energy saving) Optimized defrost Temperature sampling time during an optimized defrost (valid only if od2=yes) Tipe of synchronized defrost Differential temperature for latent heating control °C Restart regulation after dripping (valid only if Syd = nSY) Humidity regulation active during any defrost phase...
  • Page 23 Humidity alarm delay with door open Temperature alarm inhibition after any defrost Interval between sanitizations 00:00 Pr1 Sanitization time 00:00 Pr1 Relay output oA1 configuration Relay output oA2 configuration Relay output oA3 configuration Relay output oA4 configuration Alarm relay polarity Light output OFF when in stand-by Light output ON after power-on Analogue output 2 configuration...
  • Page 24 Energy saving cycle duration on working days 00:00 Pr1 Energy saving cycle starting time on weekends 00:00 Pr1 Energy saving cycle duration on weekends 00:00 Pr1 Sanitization cycle starting time on working days Sanitization cycle duration on working days 00:00 Pr1 Sanitization cycle starting time on weekends Sanitization cycle duration on weekends 00:00 Pr1...
  • Page 25: User Interaction

    FULL TOUCH – XH78T Parameter Parameter Menu - X9 Menu - Groups Upload Download Parameters Parameters Device Locked Info Menu Manuals on Dixell website: SCREEN NAME DESCRIPTION Show temperature value, measurement unit and active alarms only. It is the first screen after power on or after exit Home from other status.
  • Page 26: Technical Specifications

    GESTURE HOW-TO DESCRIPTION FEATURES DESCRIPTION Switch ON / Switch OFF: when in Virtual Keyboard, use this to turn on/off a specific Resistive load 11A (NO), 240Vac, 30k cycles; Press a specific area of the screen SPDT ONE TAP function. When in Programming mode, use this to select a parameter or a parameter Motor load 10FLA/60LRA (NO), 240Vac, 30k 10(4)A (NO), 240Vac, 100k with a finger for 1 sec...

This manual is also suitable for:

Gia gel 12Gia gel 18Gia gel 24