800 Series
Power Clamp Meter
61-802
Power Clamp
True RMS
#61-802
2
1. Transformer Jaw
2. Transformer Trigger
3. Data Hold Button
4. Rotary Function Switch
5. LCD Display
6. Function Buttons
7. Input Terminals
1
61-802
Power Clamp
3
4
True RMS
5
6
7
2

Advertisement

loading

Summary of Contents for IDEAL 800 Series

  • Page 1 #61-802 800 Series Power Clamp Meter 61-802 Power Clamp True RMS 61-802 Power Clamp True RMS 1. Transformer Jaw 2. Transformer Trigger 3. Data Hold Button 4. Rotary Function Switch 5. LCD Display 6. Function Buttons 7. Input Terminals...
  • Page 2: Lcd Display

    WARNING! Data Hold Button 1. DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE • The data hold button is used to capture and hold a reading RATINGS: on the LCD display. - Voltage is not to exceed 800 Volts. • Press the button again to release the reading. - Wattage, Resistance and Continuity functions are not to be performed on circuits capable of delivering greater than LCD Display...
  • Page 3 3 φ KVAR KVA Button In any other function • The 3 φ KVAR KVA button toggles between the KVAR/KVA • Pressing the read next button in any other function displays measurements and the PF/kW measurements in the 3 φ 3W the measurement values stored with the REC button.
  • Page 4 To measure Kilowatts and Power Factor in a single To measure Kilowatts and Power Factor in a single phase 2-wire system phase 3-wire system See section on 1 φ 3W AC+DC Power Measurements • Set rotary switch to PF/kW without jaws clamping onto any wire AC+DC Voltage/Frequency Measurements •...
  • Page 5 • The voltage value is shown on the main display and the fre- To Measure AC+DC Current and Voltage in a single quency value is shown on the upper display. phase 2-wire system • Set rotary switch to A/V Note: If the frequency is <10Hz, the display will show 0Hz. If •...
  • Page 6 3 φ 3W AC+DC Power Measurements To Measure AC+DC Apparent and Reactive Power (kVA/kVAR) in a single phase 2-wire system Kilowatt Range Resolution Accuracy Voltage/Current • Set the rotary switch to A/V. (AC+DC True Power) Range • Press the DC A/W ZERO button to zero the reading. 0-99.99kW 0.01kW ±(2.0% +0.05) 600VAC, 800VDC...
  • Page 7 L3L2 Measurement L1L2 Measurement • Select one phase to be the common phase. (eg. S or L2) • Connect the black test probe to the common phase (S or L2) • Connect the black test probe to the common phase (S or L2) and the red test probe to another phase (eg.
  • Page 8 • The power clamp processes the two sets of data and calcu- L1G Measurement lates the true power (kW) of the system, which is shown on the main display, and the power factor (PF), which is shown on the upper display. RST is shown on the LCD display to indicate that this is a measurement of the total system.
  • Page 9 3 φ 4W AC+DC Power Measurements • Connect the black test probe to ground and the red test probe to the second phase (T or L2). Kilowatt Range Voltage/Current • Using the trigger to open the jaws, fully enclose the phase (AC+DC True Power) Resolution Accuracy Range (T or L2) within the clamp.
  • Page 10 L1 Measurement • Connect the black test probe to neutral and the red test probe to the second phase (S or L2) • Using the trigger to open the jaws, fully enclose the second phase (S or L2) within the clamp. •...
  • Page 11 Power Calculations Power Factor Corrections A positive power factor indicates that an inductive load has brought the power system out of phase. Based on the kVAR values of the system, capacitors are available to improve the power factor. By measuring the frequency, phase voltage and kVAR of the system, you can calculate the capacitive load required for this correction.
  • Page 12: Maintenance

    Battery Replacement Any implied warranties arising out of the sale of an IDEAL Warning product, including but not limited to implied warranties of mer- Do not touch or adjust any components inside the clamp chantability and fitness for a particular purpose, are limited to when the back case is removed.