Troubleshooting - Kidde FIREX 4985 User Manual

Table of Contents

Advertisement

Available languages

Available languages

!
DANGER:
!
WARNING:
PROBLEM
Smoke alarm does not
sound when tested.
NOTE: Push test but-
ton for at least five (5)
seconds while testin
Smoke alarm beeps about
once a minute.
(Models 4870 and
4973 only)
(Models 4881 and
4985)
Smoke alarm sounds
unwanted alarms when
residents are cooking,
taking showers, etc.
Interconnected smoke
alarms do not sound when
system is tested.

TROUBLESHOOTING

Always turn off power at main fuse box or
consumer unit before taking trouble-shooting
action.
DO NOT disconnect battery or mains power
to quiet an unwanted alarm. This will remove
your protection. Fan the air or open a
window to remove smoke or dust. For
Models 4870, 4973, 4985 and 4881 you may
also use the Hush Button feature to quiet
unwanted alarms.
g!
7
SOLUTION
1. Check that AC power
is turned on. Green LED
should be illuminated.
2. Turn off power. Remove
smoke alarm from
mounting plate and:
a. check that connector
plug is securely
attached.
b. check that battery is
properly attached to
connector.
3. Clean smoke alarm.
1. Turn off power and
replace battery. See
Battery Replacement"
in the MAINTENANCE
AND CLEANING section.
2. Clean smoke alarm.
3. Verify that unit has been
under mains operation
for a minimum of 2 full
days. If the beeping
persists after required
charging period, return
the unit for service.
1. Hire an electrician to
move smoke alarm to a
new location. See
"SMOKE ALARM
PLACEMENT"
1. Press and hold test
button for at least
three seconds after the
first unit sounds.
2. Hire an electrician to
ensure smoke alarms
are properly connected.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firex 4881Firex 4973Firex 4870

Table of Contents