Dip Switch Tables - Epson TM-T81 User Manual

Hide thumbs Also See for TM-T81:
Table of Contents

Advertisement

Available languages

Available languages

DIP Switch Tables

Serial Interface (DIP switch 1)
SW
Function
1-1
Data reception error
1-2
Receive buffer
capacity
1-3
Handshaking
1-4
Data word length
1-5
Parity check
1-6
Parity selection
1-7
Selects transmission speed. (See table below.)
1-8
Transmission speed
Transmission speed (bps)-bits per second
Adjustable by control commands
(default: 38400)
4800
9600
19200
Serial Interface (DIP switch 2)
SW
Function
2-1
Handshaking
(BUSY condition)
2-2
Reserved (Do not
change)
2-3
Selects print
2-4
density
2-5
Release condition
of receive buffer
BUSY (If receive
buffer capacity set
to 4 K bytes.)
2-6
Reserved (Do not
change)
2-7
I/F pin 6 reset
2-8
I/F pin 25 reset
ON
OFF
Ignored
Prints "?"
45 bytes
4K bytes
XON/XOFF
DTR/DSR
7 bits
8 bits
Enabled
Disabled
Even
Odd
1-7
ON
OFF
ON
OFF
ON
OFF
Receive buffer
Offline or
full
Receive buffer
full
Fixed to OFF
See Table A.
Releases BUSY
Releases BUSY
when remaining
when
receive buffer
remaining
capacity
receive buffer
reaches
capacity
138 bytes.
reaches
256 bytes.
Fixed to OFF
Enabled
Disabled
Enabled
Disabled
USB Interface (DIP switch 1)
SW
Function
1-1
Auto line feed
1-2
Receive buffer
capacity
1-3~
Undefined
1-7
1-8
Reserved (Do not
change)
USB Interface (DIP switch 2)
SW
Function
2-1
Handshaking
1-8
(BUSY condition)
ON
2-2
Reserved (Do not
change)
ON
2-3
Print density
OFF
2-4
OFF
2-5
Release condition
of receive buffer
BUSY (If receive
buffer capacity
set to 4 K bytes.)
2-6
Reserved (Do not
2-7
change)
2-8
Reserved (Do not
change)
Table A
Print density/low power
Print density (Standard)
Print density (Darker than standard)
Print density (Darkest)
ON
OFF
Always
Always
enabled
disabled
45 bytes
4K bytes
ON
OFF
Receives buffer
Offline or
full
receives buffer
full
Fixed to OFF
See Table A.
Releases BUSY
Releases BUSY
when remaining
when
receive buffer
remaining
capacity
receive buffer
reaches
capacity
138 bytes
reaches
256 bytes.
Fixed to OFF
Fixed to ON
SW 3
OFF
OFF
ON
OFF
OFF
ON
English
SW 4
v

Advertisement

Table of Contents
loading

Table of Contents