HADEF 20/94AF-EX Installation, Operating And Maintenance Instruction page 8

Monorail trolley
Table of Contents

Advertisement

2.6.2
Surface temperature of the devices
DANGER!
The temperature class mentioned on the EX-type plate on the unit must be observed, - make sure
that the max. surface temperature is even fallen short of.
DANGER!
The maximum surface temperature of the equipment must always be lower than the ignition
temperature of the gas/vapour/dust/air mixture. Equipment which has been classified in higher
temperature classes is, of course, also approved for use in applications with lower temperature
classes. As gas/air mixtures for T5 do not occur with normal use, and only very rarely occur for T6,
for specific gas/air mixtures such as carbon disulphide (IIC), our hoists are not rated for these
temperature classes and must not be used for these classes.
2.6.3
EX zone classification
Areas that are prone to explosion are classified into zones. The owner must determine the zone that exists.
Information on the zone classification can be found in IEC 60079-10 and in national standards. The following
table contains an overview of the zone classification in combination with the device category.
Gases
device category
Vapours
Mist
Zone 0
Zone 1
Zone 2
8
Ignition tem-
Temperature
perature of gas
class
T1
>450
T2
>300 <450
T3
>200 <300
T4
>135 <200
T5
>100 <135
T6
>85
Dust
(Gases)
1G
Zone 20
2G
Zone 21
3G
Zone 22
max. surface
temperature of the
operating material in
°C
°C
450
300
200
135
100
<100
85
device category
(dust)
1D
2D
3D
explosive
atmosphere
is present
continuously, long-term or
frequently
occasionally
rarely or short-term
5.52.692.01.01.06