Rockwell Automation Allen-Bradley ASEM 6300 User Manual
Rockwell Automation Allen-Bradley ASEM 6300 User Manual

Rockwell Automation Allen-Bradley ASEM 6300 User Manual

Rvl receiver and rvl transmitter
Hide thumbs Also See for Allen-Bradley ASEM 6300:

Advertisement

Quick Links

ASEM 6300 RVL Receiver and
RVL Transmitter
Catalog Numbers
6300V-RVLDV-RX, 6300V-RVLDV-TX
User Manual
Original Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Rockwell Automation Allen-Bradley ASEM 6300

  • Page 1 ASEM 6300 RVL Receiver and RVL Transmitter Catalog Numbers 6300V-RVLDV-RX, 6300V-RVLDV-TX User Manual Original Instructions...
  • Page 2 If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 3: Table Of Contents

    Apply Power to the RVL Device ..........20 Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 4 Cables..............28 Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 5: Preface

    Some computer configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union. All I/O cables must be used only indoors. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 6: Additional Resources

    Product Certifications website, rok.auto/certifications. Provides declarations of conformity, certificates, and other certification details. Provides guidance on how to conduct security assessments, implement Rockwell Automation System Security Design Guidelines Reference Manual, publication products in a secure system, harden the control system, manage user access, and dispose of SECURE-RM001 equipment.
  • Page 7: Overview

    Figure 3 - Industrial Monitor > External RVL Receiver > Industrial PC with Integrated Transmitter Industrial Monitor Industrial PC RVL Receiver with Integrated Transmitter 6300V-RVLDV-RX DVI Cable RVL Cable USB 2.0 Cable 100 m (328 ft) Maximum Length Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 8: Approximate Dimensions

    Install the Ground Wire on page 17 for the ground connection on these models. Ground (Earth) Screw — The USB ports are not for use in hazardous locations. Only use the USB ports for initial setup and maintenance. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 9: Led Status Indicators

    Various accessories are available for an RVL receiver and RVL transmitter. A partial list of cables is listed in Cables on page 28. You can view the full list of accessories at: https://www.rockwellautomation.com/en-us/products/hardware/allen-bradley/industrial- computers-monitors.html. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 10 Chapter 1 Overview Notes: Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 11: Prepare For Installation

    Non-hazardous Locations only. • considered open equipment, which means that it can only be integrated in housings or cabinets where the product can only be accessed by authorized personnel using a key or tool. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 12: Installation Requirements

    Table 7 on page We recommend that the computer circuit be supplied with its own disconnect. Use an uninterruptible power supply (UPS) to help protect against unexpected power failure or power surges. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 13: Required Tools And Hardware

    Connect the system with a cable cross-section of 0.75…1.5 mm (from 18…16 AWG) suitable in a minimum of 75 °C (167 °F). (2) Two cables are required if your installation requires a separate RVL receiver (6300V-RVLDV-RX). Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 14 Chapter 2 Prepare for Installation Notes: Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 15: Installation

    View of Unit from Back View of Unit from Top Hook Attachment Hook Attachment View of Unit from Side DIN Rail Hook Profile DIN Rail Hook Profile DIN Rail Hook DIN Rail Hook Screws Screws Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 16: Secure Your Rvl Receiver And/Or Rvl Transmitter

    4. Insert each stripped end into the DC terminal block as shown in Table 5. Tighten the screws on top of the DC terminal block to secure the DC power wires to the torque value in Table 7 on page Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 17: Install The Ground Wire

    7. Reinstall the nut to the chassis of your RVL receiver and/or RVL transmitter. 8. Route and connect the loose end of the ground wire to an appropriate ground location according to local codes and regulations. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 18: Connect Peripheral Cables

    I/O port locations. 2. Connect the free end of the I/O cables and power cords to your hardware as shown in Figure 3. Connect the free end of the power cords to your wall outlet. Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 19: Operation

    ASEM™ products must only be used for the applications that are described in the catalog and in the technical documentation. • Contact Rockwell Automation® customer care to be sure products and components from other manufacturers can be used with your RVL device. •...
  • Page 20: Apply Power To The Rvl Device

    (LED) status indicators illuminate. For LED status indicator locations and illumination codes for your RVL receiver and/or RVL transmitter, see Table 2 on page For the location and description of each LED status indicator, LED Status Indicators on page Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 21: Technical Specifications

    Figure 8 - Wall Mount Installation: Book Mount Style 3.30 (1.30) 1.65 (0.65) 0.45 Ø 0.45 2.00 (0.18) (0.18) 9.80 (0.79) (3.70) 0.60 (0.24) Ø 0.90 (0.35) 19.20 (7.56) 15.20 16.70 (5.98) (6.57) 0.60 2.00 (0.24) (0.79) 0.85 (0.33) Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 22 0.60 2.30 (0.24) (0.91) Figure 10 - DIN Rail Installation: Book Mount Style 1.34 1.50 (0.53) 0.90 0.90 (0.59) 3.30 (0.35) (0.35) 10.74 (1.30) (4.23) 9.40 7.60 (3.70) (2.99) 15.20 (5.98) 7.60 (2.99) Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 23: Specifications

    TIP: RVL IN must be connected to RVL TX with CAT5e (or better) cable. RVL IN Suggested Cable: see Table 22 on page 28 Suggested Connectors: LAPP 21700616 Maximum Cable Length: 100 m (328 ft) Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 24: Rvl Transmitter

    Figure 12 - Wall Mount Installation: Book Mount Style 2.60 1.30 1.30 (1.02) 2.00 (0.51) (0.51) 9.48 (0.79) 0.45 (3.73) (0.18) Ø 0.45 (0.18) 14.10 12.00 (5.56) (4.72) 16.00 (6.30) Ø 0.90 2.00 1.45 (0.35) (0.79) (0.57) Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 25 (3.70) 2.30 (0.91) 0.60 (0.24) Figure 14 - DIN Rail Installation: Book Mount Style 10.74 0.55 0.55 (4.23) (0.22) (0.59) (0.22) 9.40 2.60 (3.70) (1.02) 6.00 (2.36) 12.00 (4.72) 6.00 (2.36) 2.60 (1.02) Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 26: Specifications

    RJ45 connector TIP: RVL OUT must be connected to RVL RX with CAT5E SFTP (or better) cable. RVL OUT Suggested cable: see Table 22 on page 28 Maximum cable length: 100 m (328 ft) Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 27: Connector Pinout

    TMDS Data5+ TMDS Data1+ TMDS Clock Shield TMDS Data1/3 Shield TMDS Clock + TMDS Data3- TMDS Clock – Table 18 - USB Pin No. Function Pin No. Function VCC (5V) Data+ Data - Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 28: Cables

    94.5 (3.72) SF/UTP type 30 (98.4) 30RVLFLEX flex laying 35 (114.8) 35RVLFLEX 40 (131.2) 40RVLFLEX 45 (147.6) 45RVLFLEX 50 (164) 50RVLFLEX Cat 6a for fixed 100 (328) 90.0 (3.54) 100RVLFIXED S/FTP type laying Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 29 ASEM 6300 RVL Receiver and RVL Transmitter User Manual Notes: Rockwell Automation Publication 6300V-UM001B-EN-P - October 2023...
  • Page 30 At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, ASEM, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc.

This manual is also suitable for:

Allen-bradley 6300v-rvldv-rxAllen-bradley 6300v-rvldv-tx6300v-rvldv-rx6300v-rvldv-rxtx6300v-rvldv-tx

Table of Contents