Rockwell Automation Allen Bradley ASEM 6300 User Manual
Rockwell Automation Allen Bradley ASEM 6300 User Manual

Rockwell Automation Allen Bradley ASEM 6300 User Manual

Rvl receiver and rvl transmitter

Advertisement

Quick Links

ASEM 6300 RVL Receiver and
RVL Transmitter
Catalog Numbers
6300V-RVLDV-RX, 6300V-RVLDV-TX
User Manual
Original Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Allen Bradley ASEM 6300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rockwell Automation Allen Bradley ASEM 6300

  • Page 1 ASEM 6300 RVL Receiver and RVL Transmitter Catalog Numbers 6300V-RVLDV-RX, 6300V-RVLDV-TX User Manual Original Instructions...
  • Page 2: Important User Information

    If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 3: Table Of Contents

    Apply Power to the RVL Device ..........22 Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 4 Cables..............30 Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 5: Preface

    être conformes à la norme EN 61000-3-2 sur les émissions harmoniques telle que spécifiée par la directive EMC de l'Union européenne. Tous les câbles d'E/S doivent être utilisés uniquement à l'intérieur. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 6: Additional Resources

    Industrial Components Preventive Maintenance, Enclosures, and Provides a quick reference tool for Allen-Bradley® industrial automation controls and assemblies. Contact Ratings Specifications, publication IC-TD002 Product Certifications website, rok.auto/certifications. Provides declarations of conformity, certificates, and other certification details. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 7 Notes: Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 8 Preface Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 9: Overview

    Figure 4 - Industrial Monitor > External RVL Receiver > External RVL Transmitter > Industrial PC Industrial Monitor RVL Receiver RVL Transmitter Industrial PC Cat. No. 6300V-RVLDV-RX Cat. No. 6300V-RVLDV-TX DVI Cable USB 2.0 Cable DVI Cable RVL Cable 100 m (328 ft) Maximum Length USB 2.0 Cable Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 10: Approximate Dimensions

    Ground (Earth) Screw — Note No. LED Status Indicator LED Color Description Video Green receiving video signal output Link Green linked to the RVL transmitter Flashing Green operating correctly Power Green receiving power Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 11: Rvl Transmitter I/O Ports And Led Status Indicators

    Various accessories are available for your RVL device. A partial list of cables is listed in  Cables on page 30. For a full list of accessories, see ASEM 6300V Industrial Computer and Monitor Accessories, publication 6300V-PC001. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 12 Chapter 1 Overview Notes: Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 13: Prepare For Installation

    • If this product contains batteries, they must only be changed in an • S'assurer que l' e nvironnement est classé non dangereux avant de area known to be nonhazardous. changer les piles. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 14: Installation Requirements

    Table 4 on page We recommend that the computer circuit be supplied with its own disconnect. Use an uninterruptible power supply (UPS) to help protect against unexpected power failure or power surges. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 15: Required Tools And Hardware

    Connect the system with a cable cross-section of 0.75…1.5 mm (from 18…16 AWG) suitable in a minimum of 75 °C (167 °F). (2) Two cables are required if your installation requires a separate RVL receiver (6300V-RVLDV-RX). Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 16 Chapter 2 Prepare for Installation Notes: Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 17: Installation

    DIN Rail Hook Installed with DIN Rail Hook Installed DIN Rail Hook Top View with DIN Rail Hook Installed Position with DIN rail hook upward Position with DIN rail hook upward DIN Rail Hook Side View Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 18: Secure Your Rvl Device

    (0.275 in.) Torque range to secure 0.22...0.25 N•m DC power wires (0.16...0.18 lb•ft) Torque value to reinstall DC 0.3 N•m terminal block to computer (0.22 lb•ft) Figure 7 - DC Terminal Block Assembly Steps Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 19: Install The Ground Wire

    9. Recommended: Supply the computer circuit be supplied with its own disconnect. Use an uninterruptible power supply (UPS) to help protect against unexpected power failure or power surge. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 20: Connect Peripheral Cables

    I/O port locations. 2. Connect the free end of the I/O cables and power cords to your hardware as shown in Figure 3. Connect the free end of the power cords to your wall outlet. Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 21: Operation

    ASEM™ products must only be used for the applications that are described in the catalog and in the technical documentation. • Contact Rockwell Automation® customer care to be sure products and components from other manufacturers can be used with your RVL device. •...
  • Page 22: Apply Power To The Rvl Device

    (LED) status indicators illuminate. For LED status indicator locations and illumination codes for your RVL device, see Connections and Status on page For the location and description of each LED status indicator, Accessories on page Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 23: Technical Specifications

    Figure 9 - RVL Receiver: Book Mount Installation Front View Top View with Bracket Installed with Bracket Installed 16.5 4.50 Ø 4.50 (0.65) (0.18) (0.18) 94.80 (3.73) (0.79) Ø 9 (0.35) (0.24) (6.57) (7.56) (5.98) 8.50 (0.24) (0.33) (0.79) (1.30) Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 24 Figure 11 - RVL Receiver: DIN Rail, Book Mount Installation Front View with DIN Rail Hook Installed Top View with DIN Rail Hook Installed (0.35) (0.35) 107.40 (4.23) Front View (0.59) (1.30) (3.70) 13.40 (0.53) (2.99) (5.98) (2.99) Side View (1.30) Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 25: Specifications

    TIP: RVL IN must be connected to RVL TX with CAT5e (or better) cable. RVL IN Suggested Cable: see Table 19 on page 30 Suggested Connectors: LAPP 21700616 Maximum Cable Length: 100 m (328 ft) Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 26: Rvl Transmitter

    Figure 13 - RVL Transmitter: Book Mount Installation Front View with Bracket Installed (1.02) Top View with Bracket Installed 4.50 Ø 4.50 (0.51) (0.18) 94.79 (0.18) (3.73) (0.79) Ø 9 (0.35) (6.30) (4.72) (5.55) (0.79) 14.50 (0.57) Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 27 Back View Top View with DIN Rail Installed with DIN Rail Installed Front View 107.40 (0.59) (4.23) with DIN Rail Installed (1.02) 5.50 5.50 (0.22) (3.70) (1.02) (0.22) (2.36) (4.72) (2.36) Side View Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 28: Specifications

    RJ45 connector TIP: RVL OUT must be connected to RVL RX with CAT5E SFTP (or better) cable. RVL OUT Suggested cable: see Table 19 on page 30 Maximum cable length: 100 m (328 ft) Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 29: Connector Pinout

    TMDS Data5+ TMDS Data1+ TMDS Clock Shield TMDS Data1/3 Shield TMDS Clock + TMDS Data3- TMDS Clock – Table 15 - USB Pin No. Function Pin No. Function VCC (5V) Data+ Data - Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 30: Cables

    94.5 (3.72) SF/UTP type 30 (98.4) 30RVLFLEX flex laying 35 (114.8) 35RVLFLEX 40 (131.2) 40RVLFLEX 45 (147.6) 45RVLFLEX 50 (164) 50RVLFLEX Cat 6a for fixed 100 (328) 90.0 (3.54) 100RVLFIXED S/FTP type laying Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 31 ASEM 6300 RVL Receiver and RVL Transmitter User Manual Rockwell Automation Publication 6300V-UM001C-EN-P - May 2024...
  • Page 32: Rockwell Automation Support

    At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, ASEM, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc.

This manual is also suitable for:

6300v-rvldv-rx6300v-rvldv-tx

Table of Contents