APPENDIX B—ENGAGEMENT ARM SHOCK REMOVAL (CONT.)
READ AND UNDERSTAND THE ENTIRE SET OF INSTRUCTIONS BEFORE PERFORMING ANY STEP IN THIS PROCESS
STEP 7
Install new Engagement Arm Shock (19) to mounting points,
securing with Clevis Joint Snap-In Pins (19a).
STEP 8
Cut and remove the baling wire from the Engagement Arm
Shock (19).
STEP 9
Press the Clevis Joint Snap-In Pins (19a) to their locked
position on the Yoke End Linkage (19b).
STEP 10
TESTING THE OPERATION OF THE CLAW
Lift upward on the Locking Mechanism (7) and press
downward 1-2 inches on the Engagement Arm Assembly (6),
release the Engagement Arm Assembly (6) and the
Engagement Arm Shock (19) should return the Engagement
Arm Assembly (6) to it's raised position. Repeat application
of downward pressure and allowing the Engagement Arm
Assembly (6) to return to it's raised position 3-4 times to
ensure the assembly is moving freely.