Page 9
7.23 Swing Meter Display....................... 222 7.24 Tank Gauge Display ....................... 223 7.25 Watermaker Status ......................223 7.26 Switch/Breaker Display ....................224 Alerts............................228 Displaying Active Alerts ....................228 8.1.1 Alert Status Screen ....................228 Accepting or Cancelling an Alert ..................229 8.2.1 From a Favorite Screen ....................
Page 10
DSM570 User’s Manual Table of Figures Figure 1 – NMEA 2000® Connector Face View ..................3 Figure 2 – DSM570 Power Up Screen ....................4 Figure 3 – Powerdown Countdown Screen ................... 5 Figure 4 – Keypad and Key Names ...................... 5 Figure 5 –...
® Congratulations on your purchase of the Maretron DSM570 NMEA 2000 Display. Maretron has designed and built your display to the highest standards for years of dependable and accurate service. Maretron’s DSM570 is a high-resolution color display that allows easy interpretation of NMEA 2000 ®...
2.3 Mounting the DSM570 The DSM570 can be flush mounted. Maretron suggests a location at which the display can be viewed from a relatively straight angle, and at which the keys are easily touched. 2.3.1 Flush Mounting the DSM570 The DSM570 can be directly mounted to any suitable surface.
2.4 Connecting the DSM570 ® The Maretron DSM570 provides a connection to an NMEA 2000 interface through a standard Micro ® ® NMEA 2000 connector that can be found on the back of the unit. The NMEA 2000 connector is a ®...
DSM570 User’s Manual 3 Operating the DSM570 3.1 Turning the DSM570 On To turn on the DSM570, press the power key (the leftmost of the five keys on the keypad). The DSM570 will display a warning and ask you to press the Accept key ( ) to acknowledge the warning and continue operation of the DSM570 (see Figure 2 below).
Figure 3 – Powerdown Countdown Screen 3.3 Keypad Essentials The DSM570 has a five-key keypad located below the screen. Each key has slightly different functions depending on the operating mode. Figure 4 below shows the DSM570 keys and their names. Figure 4 –...
DSM570 User’s Manual 3.3.1 Navigating in a Menu When accessing a menu, the keys on the DSM570 keypad have the following functions: ) – turns the DSM570 off (see Section 3.1 on page 4 for details). Power Key ( ) – returns to the next higher-level menu. If already at the top-level menu, exits Back Key ( menu mode returns to favorite screens mode.
Figure 5 – Entering a Textual Value The top line contains the textual string that has already been entered. New characters are appended one at a time to the end of the line, at the position marked by the underscore. To append an uppercase character, use the Scroll Up and Scroll Down buttons to select Uppercase and then press Enter to go across to the characters.
DSM570 User’s Manual To abort the entire textual edit and return to the original field without changing the contents of the field, use the Scroll Up and Scroll Down buttons to select Exit without Saving and then press Enter. To enter the text string in the original field, use the Scroll Up and Scroll Down buttons to select Save and Exit and then press Enter.
4 Important Concepts 4.1 Favorite Screens The DSM570 can display many different types of information in many different configurations. It is capable of displaying up to four distinct windows on its screen at one time. Rather than making you select from among the many types of available information any time you want to change the displayed data, the DSM570 has the concept of “Favorite Screens”.
Total Power Factor – displays power factor of the generator Total kWH Export – displays total energy produced by the generator (for the Maretron ACM100, this parameter’s value may be reset to zero with the control mode of the display – see Section 5.2.7.14 for details)
Total Power Factor – displays power factor of the utility Total kWH Export – displays total energy produced by the utility (for the Maretron ACM100, this parameter’s value may be reset to zero with the control mode of the display – see Section 5.2.7.14 for details)
DSM570 User’s Manual Phase C Current – displays phase C current of the Utility Phase C Frequency – displays frequency of the AC power on phase C of the utility Phase C L-N Voltage – displays phase C Line-to-Neutral RMS voltage of the Utility Phase CA L-L Voltage –...
This timer may be reset with the control mode of the display – see Section 5.2.7.14 for details) Hardware ON Timer – displays the value of a hardware timer in Maretron’s DCR100, SIM100 and RIM100 that accumulates the elapsed time that the indicator has spent in the ON state. This timer may be reset with the control mode of the display –...
Trip Fuel Used field of the 127497 Trip Parameters, Engine message, such as the Maretron FFM100, may be reset with the control mode of the display – see Section 5.2.7.14 for details) Warning – displays warning conditions generated by the engine 4.2.10...
4.2.12 Fuel Management WARNING: Maretron fuel management products are designed to be accurate and reliable; however, they should be used only as aids for fuel management and not as a replacement for traditional fuel management techniques. BEWARE: Conditions can quickly change that drastically effect time and distance to empty.
(fuel flow transducers that are capable of being reset via the 126208 NMEA 2000 command of the Trip Fuel Used field of the 127497 Trip Parameters, Engine message, such as the Maretron FFM100, may be reset with the control mode of the display – see Section 5.2.7.14 for details).
This timer may be reset with the control mode of the display – see Section 5.2.7.14 for details) Hardware ON Timer – displays the value of a hardware timer in Maretron’s DCR100, SIM100 and RIM100 that accumulates the elapsed time that the indicator has spent in the ON state. This timer may be reset with the control mode of the display –...
® NMEA 2000 command of the Distance Since Last Reset field of the 128275 Distance Log message, such as the Maretron DST110, may be reset with the control mode of the display – see Section 5.2.7.14 for details) Page 18...
4.2.25 Tank The DSM570 supports the display of information for up to sixteen tanks types (16 fuel plus 16 water, etc.). Capacity – displays the fluid capacity of the tank Level – displays the level of fluid in the tank as a percentage of its capacity Remaining –...
DSM570 User’s Manual 4.2.28 Transmission The DSM570 supports the display of information for up to four transmissions. Gear – displays the current gear of the transmission (forward, neutral, or reverse) Oil Pressure – displays the pressure of the oil in the transmission Oil Temp.
Page 37
True Speed – displays the speed of the wind as it would appear to an observer if the vessel was stopped in the water, calculated using speed through water (STW) or speed over ground (SOG) (depending on the unit setting of the “Wind True Vessel Ref.” Parameter, see Section 5.2.7.6) Page 21...
DSM570 User’s Manual 4.3 Alerts An alert is a signal to a user that there is either an alarm or warning condition requiring user intervention. ® Alerts are integrated in an NMEA2000 system. For each Alert, one device acts as a master, or Alert Source, and monitors a parameter against a preset threshold.
4.3.4 Vessel Alert Operating Modes You can configure alerts to operate in one or more fixed operating modes, 1) disabled, 2) moored, 3) underway, or 4) anchored. This allows you to easily enable or disable groups of individual alarms depending on the vessel’s operating mode. Setting the vessel alert operating mode is described in section 8.6.
DSM570 User’s Manual You may disable the alert at this time, causing it to become a Disabled Alert. • Awaiting Cancel – An Alert in the Awaiting Cancel state is an alert where the condition that caused the alarm or warning has been removed without the alert being accepted while it was Active.
5 Operating Modes The DSM570 has two main operating modes including normal viewing of information in the favorite screens mode (Section 5.1) and the menu mode (Section 5.2). Also, the control mode is a sub mode of the favorite screens mode, in which certain control and reset functions may be performed (Section 5.2.7.14).
DSM570 User’s Manual 5.2 Menu Mode The menu mode is entered while viewing favorite screens by pressing the Enter key ( In menu mode, the DSM570 may be configured by scrolling up and down the menu and selecting one of the submenus found there. The DSM570 Main Menu can be seen in Figure 7 below. Figure 7 –...
Selecting Alert Status… from the Main Menu will display a list of currently active Alerts in the DSM570. See section 8.1.1 for details on the Alert Status Screen. 5.2.3 Configuration Menu The configuration menu allows you to change the configuration of certain types of Maretron NMEA ® ®...
DSM570 User’s Manual Figure 9 – Device Selection Screen The “NA” column of the menu displays the node address the device is using. The “Manufacturer” column of the menu displays the manufacturer of the device. The “Model” column displays the model number of the device. The “SN#”...
DSM570 User’s Manual 5.2.4.1.2 Primary Device Selection Not all the data displayed by the DSM570 can be taken directly off the NMEA 2000 bus. Some require calculations with other parameters before the desired value can be displayed. An example would be the display of ground relative wind. In this case, the wind measured by the weather station needs to be combined with the vessel heading, course over ground, and speed over ground.
Figure 13 – DSM570 Advanced Information Screen Most of the items within the Advanced Information… menu are obvious and not described here, although a less obvious menu item (Bus Status…) is described below. 5.2.4.2.1 Bus Status ® The DSM570 is capable of monitoring the NMEA 2000 network and displaying certain statistics.
DSM570 User’s Manual 5.2.4.3 Backlight The DSM570 has three user-programmable lighting levels which may be cycled through using the Lights key ( ) on the keypad while the DSM570 is operating in favorite screens mode. Each time you quick press the Lights key ( ) in favorite screens mode, the DSM570 backlight will transition between the “Low”...
Figure 16 – Color Palette Selection Screen Use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlight to the color set that you want ). Selecting “Color Set #1” takes you to the screen to change, and then press the Enter key ( shown in Figure 17.
DSM570 User’s Manual “On”. The background will switch to black and the percentage color settings are now used to define the foreground color. The “Restore Factory Defaults” menu selection will restore all of the color sets to their factory default states.
Figure 19 – Setting the Keyboard Beep Option 5.2.4.7 Label Each DSM570 can be given a software label. Normally this label will indicate the position of the DSM570 and is used by the Alert System to identify one DSM570 from another. Figure 20 –...
DSM570 User’s Manual 5.2.5 Favorite Screens Mode The DSM570 supports two methods of operation in favorites mode: “Auto”, in which the DSM570 automatically cycles through all favorite screens that have been enabled for Auto mode, and “Manual”, in which the DSM570 continues to display the currently displayed favorite screen until you press the Scroll Up ( ) or Scroll Down ( ) keys, in which the DSM570 will display the next higher...
Figure 23 – Favorite Screen Parameters 5.2.6.1 Favorite Mode This entry allows you to select in which display method of favorite screens mode this particular favorite screen is enabled. This parameter has four possible settings: Off – this favorite screen is disabled and is not displayed Auto –...
DSM570 User’s Manual • 2 Qtrs – Half Bottom – three parameters will be displayed, the first occupying the upper left- hand corner of the screen, the second occupying the upper right-hand corner of the screen, and the third occupying the bottom half of the screen •...
5.2.6.4 Window Data The Window Data section of the menu allows you to select a particular type of data to be displayed in each part of the screen. Selecting the data to be displayed is a two-step process. First, press the Enter key ( ) and select the category of data to be displayed.
Page 56
DSM570 User’s Manual • Bar Graph (see Section 7.2 on page 206) • Compass Rose (see Section 7.3 on page 206) • Date (see Section 7.4 on page 208) • Date/Time (see Section 7.5 on page 208) • Gauge (see Section 7.4 on page 208) •...
Likewise, the DSM570 can’t calculate magnetic course given true course from a GPS if variation isn’t available. You can setup a favorite screen to display variation, which will help you determine whether or not you have a product on the network broadcasting variation information (Maretron’s GPS’s use the World Magnetic Model to broadcast variation).
Page 58
DSM570 User’s Manual • Meters • Fathoms • Feet 5.2.7.3 Distance This menu item allows you to select the units to be used for the display of all distance-related information. Units that may be selected are the following: • Nautical Miles •...
Page 59
• °F • °C 5.2.7.8 Atmospheric Pressure This menu item allows you to select the units to be used for the display of atmospheric (barometric) pressure. Units that may be selected are the following: • Inches Mercury (in Hg) • Bar •...
Page 60
DSM570 User’s Manual • DD-MMM-YYYY (31-JAN-2005) 5.2.7.14 Force This menu item allows you to select the units to be used for the display of force. Units that may be selected include the following: • Newtons • Kilograms • Pounds 5.2.7.15 Mass This menu item allows you to select the units to be used for the display of mass.
5.2.7.19 Motion Velocity This menu item allows you to select the units to be used for the display of velocity. Units that may be selected include the following: • Meters/Second • Inches/Second • Feet/Second • km/Hour • miles/hour • knots 5.2.7.20 Motion Acceleration This menu item allows you to select the units to be used for the display of acceleration.
Page 62
® NMEA 2000 command message, such as the Maretron DST110, may be reset with the control mode of the display – see Section 5.2.7.14 for details For resetting “Engine Total Fuel Used”, “Trip Volume”, or “Trip Log”, use the following procedure to reset the total in the transducer providing the value.
Maretron Alternating Current Monitor (ACM100) – set circuit type, device type, instance number, and label. Reset the total energy recorded. Maretron Annunciator (ALM100) – set the data instance number and the label. Test the alarm. Maretron Current Loop Monitor (CLM100) – set the channel operating mode, set transducer characteristics, and set damping Maretron Direct Current Monitor (DCM100) –...
Page 64
DSM570 User’s Manual Maretron Run Indicator Monitor (RIM100) – set data instance for the device, and labels for the device and each channel. Maretron Switch Indicator Monitor (SIM100) – set data instance for the device, and labels for the device and each channel. Set each channel mode.
Figure 29 – Device Configuration Screen The “NA” column of the menu displays the node address the device is using. The “Manufacturer” column of the menu displays the manufacturer of the device. The “Model” column displays the model number of the device. The “SN#”...
DSM570 User’s Manual 6.1 Airmar Depth/Speed/Temperature Transducers The DSM570 supports configuration and calibration of the following Airmar ® Depth/Speed/Temperature transducers that have NMEA 2000 interfaces: • DST800 • DT800 • P39 • P79 • B122 • ST850 • ST800 • HT200 The following calibration functions are supported (not all functions apply to every model of transducer): •...
DSM570 User’s Manual 6.1.6 Speed Calibration The Airmar speed transducer speed through water (STW) initial accuracy is significantly affected by the location or placement of the speed transducer within the hull. The speed transducer can be corrected for these inaccuracies using the speed calibration procedure. You calibrate the speed ) with the “Speed Calibration…”...
these steps. Use the Increase ( ) and Decrease ( ) keys to adjust the display value until it matches the known sea temperature. Press the Accept ( ) key to accept the value when you are satisfied. If you do not wish to perform temperature calibration at this time, press the Abort ( ) key and the temperature calibration will not be altered.
DSM570 User’s Manual Figure 34 – Setting the Transducer Depth Offset in an Airmar Depth Transducer With the offset value highlighted, you can change the offset by using the Increase and Decrease keys . Once you have selected the desired offset, push the Enter key ( ) to complete the transducer depth offset calibration.
6.2 Bennett EP-30 (NMEA1) Trim Tabs Configuration This describes the configuration of the Bennett EP-30 trim tabs firmware version 1.0.7 (“NMEA1” NMEA 2000 Trim Tab Indicator Kit). The EP-30 configuration menu is shown below in Figure 36 below, and currently has the single entry “Trim Tabs Calibration…”. Figure 36 –...
DSM570 User’s Manual After you press the Accept ( ) key, a screen, shown in Figure 38 below, appears, instructing you to now lower both trim tabs to the full down position. It is important that you do this without stopping in order for the calibration process to succeed.
6.3 Maretron ACM100 Configuration This describes the configuration of the Maretron ACM100 firmware version 1.0.8.2. Figure 40 – ACM100 Configuration Screen 6.3.1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user. Typically, advanced configuration is only done at installation and should not need to be done while at sea.
Page 74
DSM570 User’s Manual 6.3.1.2 Current Transformer B The ACM100 with firmware revision 1.0.7 or newer supports two different types of current sensors: the 100A current sensor included with the unit and an optional 400A current sensor. This menu entry allows you to indicate which type of current sensor you have installed for phase B. 6.3.1.3 Current Transformer C The ACM100 with firmware revision 1.0.7 or newer supports two different types of current sensors: the 100A current sensor included with the unit and an optional 400A current sensor.
DSM570 User’s Manual You can enable or disable the transmission of a PGN message or set the frequency of transmission of the message by pressing the Enter key ( ) on the message to be configured. Options are: • Off – The PGN will not be transmitted •...
6.3.5 Label A device label may be assigned to the ACM100 as an aid to identifying the device over the network (i.e., Shore Power or Port Generator, etc.). Typically, this label will describe the equipment to which the ACM100 is connected. See section 3.3.4 for details on how to enter a textual value. 6.3.6 Reset Total Energy Recorded The ACM100 will accumulate the total amount of energy produced by a Generator or a Utility.
DSM570 User’s Manual 6.4 Maretron ALM100 Configuration This describes the configuration of the Maretron ALM100 firmware version 1.0.5. Figure 44 – ALM100 Configuration Screen 6.4.1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user.
DSM570 User’s Manual 6.4.3 Label A label may be assigned to the ALM100 as an aid to identifying the device over the network. Typically, this label will describe the location of the ALM100. See section 3.3.4 for details on how to enter a textual value. 6.4.4 Test Annunciator The Annunciator may be tested by scrolling the cursor to highlight this entry and then pressing the Enter button.
6.5 Maretron CLM100 Configuration This describes the configuration of the Maretron CLM100 firmware version 1.0.1.6. Figure 47 – CLM100 Configuration Screen 6.5.1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user. Typically, advanced configuration is only done at installation and should not need to be done while at sea.
DSM570 User’s Manual installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later. See section 3.3.4 for details on how to enter a textual value. 6.5.1.3 NMEA2000 PGN Enable/Disable The CLM100 Current Loop Monitor can transmit the NMEA2000 PGNs #65286, 127751, 130313, 130314, 130816, and 130840 which can be turned on or turned off by the DSM570 display.
6.5.3 Channel Configuration Individual channels may be configured by using the Scroll Up and Scroll Down buttons to highlight the channel, and then pressing the Enter key. The following screen will be displayed. Figure 50 – CLM100 Channel Configuration Screen 6.5.3.1 Label A label may be assigned to each channel of the CLM100 as an aid to identifying the parameter that is being displayed.
Page 84
You can configure a damping parameter to smooth the parametric readings or make them more responsive. The data damping is configurable between 0.1-25.0 seconds. The default data damping period is 3.0 seconds. \\richpc\maretron\Projects\DCM\DCM100\Manual\Configuring DCM100 with DSMxxx.docx Page 68 Revision 1.8.3...
6.6 Maretron DCR100 Configuration The DSM570 is capable of configuring the Maretron DCR100 DC Relay device. This section describes the configuration of the Maretron DCR100 firmware version 1.1.1. The main DCR100 configuration screen is shown below. Figure 51 – DCR100 Configuration Screen 6.6.1 Advanced Configuration...
DSM570 User’s Manual Figure 53 – DCR100 Current Sensor Zero Offset Calibration Screen Press Begin to execute the calibration process or Cancel to return to the previous menu. During the calibration process, all channels will be turned off. When the calibration is complete, the following screen will be displayed.
This option restores all settings on the device to their factory default state. 6.6.2 Device Label This entry allows you to assign a text label to the device. This label is visible in Maretron analysis and display products and allows you to easily identify the particular device.
Figure 56 – DCR100 Channel Configuration Screen (DCR Mode) 6.6.4.1.1 Label This entry allows you to assign a text label to the device. This label is visible in Maretron analysis and display products and allows you to easily identify the particular device.
Figure 57 – DCR100 Channel Configuration Screen (ALM Mode) 6.6.4.2.1 Label This entry allows you to assign a text label to the device. This label is visible in Maretron analysis and display products and allows you to easily identify the particular device.
You can use the DSM570 to configure other remotely-located DSM200 units by using the Remote DSM200 configuration menu shown in Figure 58 below. This describes the configuration of the Maretron DSM200 firmware version 1.10. There is one configurable item for the remote DSM200 configuration and that is “Remote Device Selection…”.
Page 91
The “NA” column of the menu displays the node address the device is using. The “Manuf.” column of the menu displays the manufacturer of the device. The “Model” column displays the model number of the device. The “SN#” column displays the serial number of the device, so that any of two or more devices of the same manufacturer and model number may be distinguished from one another.
You can use the DSM570 to configure other remotely-located DSM150, DSM250, DSM410, and DSM570 units by using the Remote DSM150/DSM250/DSM410/DSM570 configuration menu as shown in Figure 60 below. This describes the configuration of the Maretron DSM150/DSM250/DSM410/DSM570 firmware version 1.8.3. There are three configurable items for the remote DSM150/DSM250/DSM410/DSM570: “Remote Device Selection…”, “Copy device...
Figure 61 – DSM150/DSM250/DSM410/DSM570 Remote Device Selection Screen The “NA” column of the menu displays the node address the device is using. The “Manuf.” column of the menu displays the manufacturer of the device. The “Model” column displays the model number of the device. The “SN#”...
DSM570 User’s Manual Figure 62 – DSM150/DSM250/DSM410/DSM570 Copy alarms settings from local display After you select this menu item and press Enter, the alarm settings from this DSM570 unit will be copied to the selected remote DSM150/DSM250/DSM410/DSM570 unit. 6.8.3 Copy device selection from local display Since it is normally desirable for all DSM150/DSM250/DSM410/DSM570 units on a network to display the same sensors, it is possible to copy the device selection settings from a DSM570 unit to a remotely located DSM150/DSM250/DSM410/DSM570.
6.8.4 Copy display settings from local display Figure 64 – DSM150/DSM250/DSM410/DSM570 Copy display settings from local display 6.8.5 Copy favorite settings from local display It is also possible to copy the favorite screen settings from one DSM570 to a remote DSM150/DSM250/DSM410/DSM570 unit.
DSM570 User’s Manual Figure 66 – Favorite Settings Transfer Completion Screen 6.8.6 Copy DST100 calibrations from local display DST100 calibration data is not stored in the DST100 device. Rather each DSM150/DSM250/DSM410/DSM570 needs to apply its own set of calibration parameters to the raw data received.
Also use this function to copy settings from an old DSM150/DSM250/DSM410/DSM570 to a new DSM150/DSM250/DSM410/DSM570 when replacing the device. Figure 68 – DSM150/DSM250/DSM410/DSM570 Copy all settings from local display 6.8.8 Label The Label of the DSM150/DSM250/DSM410/DSM570 is used by the Alert System to identify the source of an alert.
6.9 Maretron DST100 Configuration The DSM570 is capable of configuring Maretron’s DST100 for several different parameters including trip log resetting, transducer depth offset, and speed calibration. This describes the configuration of the Maretron DST100 firmware version 1.0.1. Figure 71 – DST100 Configuration Screen 6.9.1 Advanced Configuration...
be altered. The speed calibration process provides a method for the actual STW reading produced by the DST100 to be adjusted within the DSM570 (i.e., calibration data is not stored within the DST100). WARNING: Unlike resetting the trip log and setting the depth offset, which actually programs the DST100 so that all displays receive the same information, speed calibration must be performed at individual displays in order to show calibrated speed through water.
DSM570 User’s Manual “Reset” menu item is selected will complete the operation. Resetting the trip log zeroes the DST100’s trip log such that all displays receive a zeroed value (i.e., you don’t have to perform the operation from other display locations). Figure 75 –...
6.10 Maretron DST110 Configuration The DSM570 is capable of configuring Maretron’s DST110 for several different parameters including trip log resetting, transducer depth offset, temperature calibration, and speed calibration. Figure 76 – DST110 Configuration Screen 6.10.1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user.
6.10.3 Speed Calibration The DST110 speed through water (STW) initial accuracy is significantly affected by the location or placement of the DST110 within the hull. The DST110 can be corrected for these inaccuracies using the speed calibration procedure. You calibrate the DST110 STW by pressing the Enter key ( ) with the “Speed Calibration…”...
DSM570 User’s Manual wish to perform temperature calibration at this time, press the Abort ( ) key and the temperature calibration will not be altered. Figure 80 - DST110 Water Temperature Calibration Screen 6.10.6 Transducer Depth Offset The DSM570 can set the transducer depth offset parameter in a DST110 depth/speed/temperature transducer.
With the offset value highlighted, you can change the offset by using the Increase and Decrease keys . Once you have selected the desired offset, push the Enter key ( ) to complete the transducer depth offset calibration. This procedure actually programs the offset value into the DST110 such that all displays subsequently receive the offset information.
DSM570 User’s Manual 6.11 Maretron EMS100 Configuration This describes the configuration of the Maretron EMS100 firmware version 1.4.1. The EMS100 is configured to match the engine to which it is connected. The EMS100 Configuration changes some complex parameters within the device and should only be performed by an advanced user.
must select the correct type of gauge for this setting in order for the data to be displayed correctly. Valid options are: • No Gauge – select this option if there is no boost pressure gauge present. • YANMAR Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key. 6.11.3 Boost Pressure Sender Type The EMS100 comes from the factory preprogrammed with the characteristics of boost pressure...
DSM570 User’s Manual Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key. 6.11.7 Drive Trim Sender Offset Often, the characteristics of individual drive trim senders vary from their specified values. This setting allows you to apply an offset to the resistance value of the drive trim sender in order to allow you to bring the digital value reported by the EMS100 into agreement with that displayed by the analog gauge.
Select the required option using the Increase and Decrease keys followed by the Enter key. 6.11.11 Water Temperature Gauge Type The EMS100 comes from the factory preprogrammed with the characteristics of water temperature gauge types for supported engines. If the EMS100 is used with an analog water temperature gauge, you must select the correct type of gauge for this setting in order for the data to be displayed correctly.
DSM570 User’s Manual 6.11.15 Tachometer Flywheel Teeth The EMS100 needs to know the number of flywheel teeth on the engine (or the number of alternator pulses per revolution) in order to correctly calculate engine RPM. Use this setting to program the EMS100 with the number of flywheel teeth or alternator pulses per revolution for the engine to which the EMS100 is connected.
6.12 Maretron FFM100 Configuration The DSM570 is capable of configuring the Maretron FFM100 Fluid Flow Monitor. This describes the configuration of the Maretron FFM100 firmware version 1.1.2. Figure 85 – FFM100 Configuration Screen 6.12.1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user.
Page 114
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
Figure 87 – FFM100 NMEA PGN Enable/Disable Screen You can enable or disable the transmission of a PGN message or set the frequency of transmission of the message by pressing the Enter key ( ) on the message to be configured. Options are: Off –...
DSM570 User’s Manual 6.12.4.1 Channel #0 (Differential Mode) This section describes the Channel #0 configuration parameters when the FFM100’s operating mode has been set to “Differential”. The Channel #0 (Differential Mode) menu is too large to fit on a single screen, so it is shown in two separate screenshots below.
Page 117
6.12.4.1.9 Temperature Label Program this parameter with a text string which identifies the particular temperature parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 6.12.4.1.10 Flow Instance Program this parameter to match the desired instance number of the fluid flow reading for this channel.
0. 6.12.4.1.13 Volume Label Program this parameter with a text string which identifies the particular volume parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 6.12.4.2 Channel #0 Configuration Menu (Two Independent Sensors Mode) This section describes the Channel #0 configuration parameters when the FFM100’s operating mode...
Page 119
6.12.4.2.1 Sensor You may select whether this channel is connected to a “3-phase” sensor (Maretron fuel flow sensors with three pulse outputs), or a “1-phase” sensor (other manufacturer’s fluid flow sensors with a single pulse output). 6.12.4.2.2 Engine Instance Program this parameter to match the desired engine instance number of the flow rate and total fuel used for this channel.
6.12.4.2.12 Flow Label Program this parameter with a text string which identifies the particular fluid flow parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 6.12.4.2.13 Volume Instance Program this parameter to match the desired instance number of the volume reading for this channel.
6.12.5.1.6 Temperature Label Program this parameter with a text string which identifies the particular temperature parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. Revision 1.8.3 Page 105...
Figure 94 – FFM100 Channel #1 Second Configuration Screen (Two Independent Sensors Mode) 6.12.5.2.1 Sensor You may select whether this channel is connected to a “3-phase” sensor (Maretron fuel flow sensors with three pulse outputs), or a “1-phase” sensor (other manufacturer’s fluid flow sensors with a single pulse output). 6.12.5.2.2...
Page 123
6.12.5.2.9 Temperature Label Program this parameter with a text string which identifies the particular temperature parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 6.12.5.2.10 Fluid Type Program this parameter to match the type of fluid whose flow is being monitored.
6.12.5.2.12 Flow Label Program this parameter with a text string which identifies the particular fluid flow parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 6.12.5.2.13 Volume Instance Program this parameter to match the desired instance number of the volume reading for this channel.
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
DSM570 User’s Manual You can enable or disable the transmission of a PGN message or set the frequency of transmission of the message by pressing the Enter key ( ) on the message to be configured. Options are: Off – The PGN will not be transmitted On –...
“Tank”. 6.13.2.1.2 Label This entry allows you to assign a text label to the device. This label is visible in Maretron analysis and display products and allows you to easily identify the particular device. 6.13.2.1.3...
DSM570 User’s Manual • Custom Calibration – use for non-rectangular tanks (also, most accurate in any case, but requires more effort) • Rectangular Tank – By inputting some dimensions of a rectangular tank, the FPM100 is able to interpolate the volume of liquid from the bottom of the tank to the surface. Figure 100 –...
Figure 101 – Tank Levels Calibration Capacity Estimation The next step in the calibration process is to fill the tank and indicate the volume of fluid in the tank at various points while filling the tank. This process should be started with an empty tank. You only need to indicate two calibration points for a rectangular tank and can use up to 16 calibration points for a tank with a more complex shape.
DSM570 User’s Manual Figure 103 – Intermediate Level Calibration Once the tank is completely full, instead of pressing the Accept key to store the current calibration point, press the Complete key. This will complete the calibration process and will also adjust the tank capacity to the currently indicated level.
Figure 105 – Custom Tank Level Calibration Confirmation Screen 1.1.1.1.1.2 Rectangular Tank This menu allows calibration of the FPM100 for tanks with a rectangular cross-section. Empty Tank Depth - enter the depth of the fluid when the tank is empty (this distance is usually zero) Full Tank Depth - enter the depth of the fluid when the tank is full (this is the distance from the surface of the fluid to the bottom of the tank) Fluid Density - enter the density of the fluid whose depth is being measured.
DSM570 User’s Manual • Fuel • Fresh Water • Waste Water • Live Well • Oil • Black Water • Reserved-1…Reserved-7 – These values may be used when the contents of the tank does not fit into one of the categories above. 6.13.2.1.9 Data Damping Period If the channel’s Function is set to Tank, the default data damping period is 16.0 seconds.
Function is set to Pressure/Vacuum, the default data damping period is 3.0 seconds. 6.14 Maretron GPS100 Configuration This describes the configuration of the Maretron GPS100 firmware version 2.0.1. Some versions of the GPS100 have a different set of firmware that is currently at version 1.6.14. The configuration of these devices is identical to version 2.0.1 shown here.
GPSs on the network, this should be left at zero. 6.14.1.2 GPS Antenna Altitude The DSM570 is capable of setting the antenna altitude on a Maretron GPS100. You can choose this ) with the “Antenna Altitude:” menu item selected which causes setting by pressing the Enter key ( the screen shown in Figure 110 to be displayed.
If a three-dimensional position fix is obtainable, this value is not used. 6.14.1.3 Elevation Mask The DSM570 is capable of setting the Elevation Mask on a Maretron GPS100. You can choose this ) with the “Elevation Mask:” menu item selected which causes setting by pressing the Enter key ( the screen shown in Figure 111 to be displayed.
DSM570 User’s Manual Figure 112 – Configuring PDOP Mask on a GPS100 The allowable values for PDOP Mask are between 1 and 20. This number represents the Position Dilution of Precision, which indicates the accuracy of the computed position and is a function of the positions of the received satellites.
) keys followed by the Enter key ( 6.14.1.8 Restore Factory Defaults The DSM570 is capable of restoring all programmable settings on a Maretron GPS100 to the factory ) with the “Restore default condition. You can choose this setting by pressing the Enter key ( Factory Defaults”...
Figure 115 – Restoring Factory Defaults on the GPS100 6.14.2 Cold Start GPS The DSM570 is capable of restarting the GPS algorithm on a Maretron GPS100. You can choose this ) with the “Cold start GPS Engine” menu item selected which setting by pressing the Enter key ( causes the screen shown in Figure 116 to be displayed.
See section 3.3.4 for details on how to enter a textual value. 6.14.5 SBAS (WAAS) Enable/Disable The DSM570 is capable of enabling or disabling the SBAS (WAAS) function on a Maretron GPS Antenna/Receiver (GPS100). You can change this setting by pressing the Enter key ( ) with the “SBAS: WAAS,EGNOS,MSAS:”...
DSM570 User’s Manual Figure 118 – Configuring SBAS on a GPS100 The allowable options for SBAS configuration are either “Disable” which causes the GPS100 not to use SBAS satellites, or “Enable” which causes the GPS100 to use SBAS satellites for developing a position fix.
6.15 Maretron GPS200 Configuration This describes the configuration of the Maretron GPS200 firmware version 3.5.0. The GPS200 has several different programmable parameters that are configurable by the DSM570 display. Normally, it is not necessary to configure the GPS200 although there may be some circumstances where configuration is desirable.
) keys followed by the Enter key ( 6.15.1.4 Restore Factory Defaults The DSM570 is capable of restoring all programmable settings on a Maretron GPS200 to the factory ) with the “Restore default condition. You can choose this setting by pressing the Enter key ( Factory Defaults”...
Figure 122 – Restoring Factory Defaults on the GPS200 6.15.2 Cold Start GPS The DSM570 is capable of restarting the GPS algorithm on a Maretron GPS200. You can choose this ) with the “Cold start GPS Engine” menu item selected which setting by pressing the Enter key ( causes the screen shown in Figure 116 to be displayed.
DSM570 User’s Manual Figure 124 – Configuring SBAS on a GPS200 The allowable options for SBAS configuration are either “Disable” which causes the GPS200 not to use SBAS satellites, or “Enable” which causes the GPS200 to use SBAS satellites for developing a position fix.
6.16 Maretron IPG100 Configuration This describes the configuration of the Maretron IPG100 firmware version 3.6.0. The DSM570 is capable of configuring settings for the Internet Protocol Gateway (IPG100). A screenshot of the IPG100 configuration menus is shown in Figure 125 below.
® installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later. The default installation description is blank text.
6.16.1.4 This entry shows a window displaying the current status of the connection to Maretron Cloud Services. Maretron Technical Support personnel may ask for the information in this window if there is a problem connecting to Maretron Cloud Services. Revision 1.8.3...
Windows PC, or an iOS or Android smartphone or tablet. If you have an active Maretron Cloud Services account, you must change this setting to “Enable” so that the IPG100 will connect to Maretron Cloud Services. If you do not use Maretron Cloud Services, change this setting to “Disable”.
If the “DHCP” parameter is set to “No”, you will need to configure this parameter. 6.17 Maretron J2K100 Configuration This describes the configuration of the Maretron J2K100 firmware version 1.0.13.2. The DSM570 is capable of configuring settings for the J1939 to NMEA 2000® Gateway (J2K100). A screenshot of the J2K100 configuration menu is shown in Figure 130 below.
DSM570 User’s Manual Figure 130 – J2K100 Configuration Screen 6.17.1 Advanced Configuration Advanced Configuration changes some complex parameters within the device and should only be performed by an advanced user. Typically, advanced configuration is only done at installation and should not need to be done while at sea. Figure 131 –...
DSM570 User’s Manual Figure 133 – J2K100 Request Engine Hours Configuration 6.17.1.6 NMEA2000 PGN Enable/Disable The J2K100 interface transmits several different messages, which can be turned on or turned off by ) with “NMEA2000 PGN Enable/Disable…” menu the DSM570 display. Pressing the Enter key ( item selected causes the DSM570 to display the following screen.
6.17.2 Device Label A label may be assigned to the J2K100 as an aid to identifying the device over the network. See section 3.3.4 for details on how to enter a textual value. NMEA 2000 Instance – Engine 6.17.3 This entry allows the engine to be mapped to an NMEA2000 instance number. Each engine on an ®...
DSM570 User’s Manual own J2K100 Gateway. The J1939 Source Address (see section 6.17.4) identifies the transmission on the J1939 network, the Transmission Instance identifies the transmission to the NMEA2000 network. Figure 136 – J2K100 NMEA2000 Transmission Instance Configuration Use the Scroll Up ( ) or Scroll Down ( ) keys to change the value to the desired value you wish to use as the transmission instance identifier, and then press the Enter key (...
Figure 137 – J2K100 NMEA2000 AC/Icemaker Instance Configuration Use the Scroll Up ( ) or Scroll Down ( ) keys to change the value to the desired value you wish, and then press the Enter key ( ) to accept the value and store it within the J2K100. 6.17.6 J1939 Source Address Configuration A J1939 engine/genset and transmission has its own source address on the J1939 network, which is...
Enter button. 6.18 Maretron NBE100 Configuration The DSM570 is capable of configuring the Maretron NBE100 Network Bus Extender. This describes the configuration of the Maretron NBE100 firmware version 1.0.0. The NBE100 configuration menu is shown in Figure 139 below.
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
6.19.1.3 NMEA2000 PGN Enable/Disable The RAA100 Rudder Angle Adapter transmits the NMEA2000 PGN #127245 which can be turned on or turned off by the DSM570 display. Pressing the Enter key with “NMEA2000 PGN Enable/Disable…” menu item selected causes the DSM570 to display the following screen (Figure 143).
DSM570 User’s Manual Figure 144 – RAA100 Label Configuration See Section 3.3.4 for details on how to enter a textual value. 6.19.3 Rudder Angle Calibration In order for the RAA100 to indicate an accurate rudder angle, it must know how the resistance of the resistive rudder angle sender corresponds to the rudder angle.
standard values of resistances for rudder angle senders and for rudders with maximum port and starboard angles of anything other than 45°. To perform custom calibration of the rudder angle sender, use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlighted cursor over the “Custom Calibration…”...
DSM570 User’s Manual The second step in the custom rudder angle sender calibration process is to turn the wheel so that the rudder is centered as much as possible. Next, press Enter to accept the value and store it within the RAA100.
Figure 150 – RAA100 Custom Rudder Calibration Confirmation Screen 6.19.3.2 Set to American Standard (240-33 ohm) Use the option for rudders using a rudder angle sender with the standard American resistance range (240 ohms at full port 45°, 33 ohms at full starboard 45°). 6.19.3.3 Set to European Standard (0-180 ohm) Use this option for rudders using a rudder angle sender with the standard European resistance range...
DSM570 User’s Manual Figure 151 – RAA100: Setting the Rudder Number 6.19.5 Operating Mode The RAA100 can be operated in one of two operating modes, depending on the installation. • NMEA 2000 (the only thing that is connected to the resistive sender is the RAA100) •...
6.19.6 Gauge Resistance, + to Sender If the desired operating mode is “NMEA 2000 & Analog Gauge”, the two gauge resistances must be programmed (please refer to the RAA100 User’s Manual for details on how to perform these measurements). A screenshot of the + to sender gauge resistance configuration is shown in Figure 153 below.
6.20 Maretron RIM100 Configuration This describes the configuration of the Maretron RIM100 firmware version 1.1.1. The DSM570 may be used to configure the channels on the Run Indicator Module (RIM100). After selecting the RIM100 from the list of devices on the network, the following screen will be displayed.
6.20.3 Instance From here the instance used in the data message may be set. 6.20.4 Channel Configuration To configure an individual channel, use the Scroll Up and Scroll Down buttons to highlight the channel, and then press Enter. The following screen will be displayed. Figure 158 –...
DSM570 User’s Manual 6.21 Maretron SIM100 Configuration This describes the configuration of the Maretron SIM100 firmware version 1.1.1. The DSM570 may be used to configure the channels on the Switch Indicator Module (SIM100). After selecting the SIM100 from the list of devices on the network, the following screen will be displayed.
DSM570 User’s Manual 6.21.3 Instance From here the instance used in the data message may be set. 6.21.4 Channel Configuration To configure an individual channel, use the Scroll Up and Scroll Down buttons to highlight the channel, and then press Enter. The following screen will be displayed. Figure 162 –...
6.22 Maretron SMS100 Configuration This describes the configuration of the Maretron SMS100 firmware version 2.0.1.9. The display may be used to configure the Device Instance and Installation Description on the SMS (Text) Module (SMS100). After selecting the SMS100 from the list of devices on the network, the following screen will be displayed.
® installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later. The default installation description is blank text. See Section 3.3.4 for details on how to enter a textual value.
• Bit Error Rate – This entry shows the bit error rate of the cellular network connection. This figure may be requested by Maretron technical support personnel. The middle section of the screen allows you to send a SMS text message to an arbitrary phone number.
DSM570 User’s Manual 6.23 Maretron SSC200/SSC300 Configuration This section describes the configuration of the Maretron SSC200 firmware version 5.0.3 and SSC300 firmware version 1.0. Nine configurable parameters for the Maretron SSC200/SSC300 solid state compass may be configured using the Maretron DSM570 display. The Maretron SSC200/SSC300 configuration menu can be seen in Figure 167 below.
DSM570 User’s Manual The last line in the menu enables you to program the lifetime of the variation data received by the SSC200/SSC300. In Figure 170, you can see that the “Variation Time” has been programmed to 5.0 seconds. This means that if the compass has not received magnetic variation for five seconds, it will no longer transmit true heading data, as the variation data it has received is now expired.
The installation offset (i.e., misalignment of installed SSC200/SSC300 with vessel’s center line) may be calibrated using the Maretron DSM570 display. While executing “Installation Offset Calibration”, the vessel must stay still with no pitch and roll because SSC200/SSC300 will also calibrate pitch and roll at this time.
DSM570 User’s Manual Figure 173 – SSC200/SSC300 Installation Offset Calibration Screen Use the Increase ( ) and Decrease ( ) keys to adjust the display value until it matches the known heading to which the boat is pointed. Press the Accept ( ) key to accept the value when you are satisfied.
6.23.5 Magnetic Deviation Calibration The DSM570 is capable of performing magnetic deviation calibration on a Maretron SSC200/SSC300 solid state compass. The Rate of Turn Offset Calibration (Section 6.23.8) should be done before the Deviation Calibration. The first screen (Figure 175) gives instructions for performing the procedure.
DSM570 User’s Manual Figure 176 – SSC200/SSC300 Magnetic Deviation Calibration Progress Screen This progress screen shows the number of circles completed, the current heading, the current rate of turn, and the current status of compass calibration. If you do not wish to continue magnetic deviation calibration at this time, press Abort ( ), and the currently stored deviation tables will be retained.
6.23.8 Rate of Turn Zero Offset Calibration The DSM570 is capable of displaying rate of turn information from a Maretron SSC200/SSC300 compass. Although the compass provides very accurate rate of turn information, it can drift off of zero even though the vessel is not turning. Fortunately, the SSC200/SSC300 can learn the zero offset for different conditions found on the vessel.
DSM570 User’s Manual the SSC200/SSC300 User’s Manual for more details on the use of magnetic variation by the SSC200/SSC300 compass. By default, the SSC200/SSC300 is capable of receiving variation information on either its NMEA ® 0183 or NMEA 2000 interfaces. This causes the SSC200/SSC300 to use variation data from either ®...
® Figure 182 below shows the NMEA 2000 source selected. Figure 182 – Setting Variation Source to NMEA 2000 ® Only ® If there is no magnetic variation source available on either the NMEA 2000 or the NMEA 0183 interface, and you wish to display true heading information, you may manually enter a magnetic variation.
Page 186
DSM570 User’s Manual transmit any variation information and heading information will be available only in magnetic heading format. WARNING: Magnetic variation changes as your location on the earth changes; therefore, magnetic variation should be adjusted with changes in position. Neither the DSM570 nor the SSC200/SSC300 will make these changes automatically;...
6.24 Maretron TLA100 Configuration Maretron TLA100 tank level adapters on the network may be configured using the DSM570. This describes the configuration of the Maretron TLA100 firmware version 1.6.15. The TLA100 configuration menu is shown in Figure 184 below. Figure 184 – TLA100 Configuration Screen 6.24.1...
To program the tank capacity, use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlighted cursor over the “Tank Capacity:” menu item. Then, press the Enter key ( ) to move the highlight over the numerical tank capacity value. Use the “Increase” and “Decrease” keys to change the value to the desired tank capacity value, and finally, press the Enter key ( ) to confirm your selection and store the value within the TLA100.
DSM570 User’s Manual • Custom Calibration – use for non-rectangular tanks or non-standard sensors (also, most accurate in any case, but requires more effort) • Set to American Standard (240-33 ohm) – use for rectangular tanks using a tank level sender with the standard American resistance range (240 ohms at full, 33 ohms at empty).
Figure 190 – Tank Levels Calibration Capacity Estimation The next step in the calibration process is to fill the tank and indicate the volume of fluid in the tank at various points while filling the tank. This process should be started with an empty tank. You only need to indicate two calibration points for a rectangular tank and can use up to 16 calibration points for a tank with a more complex shape.
DSM570 User’s Manual Figure 192 – Intermediate Level Calibration Once the tank is completely full, instead of pressing the Accept key to store the current calibration point, press the Complete key. This will complete the calibration process and will also adjust the tank capacity to the currently indicated level.
Figure 194 – Custom Tank Level Calibration Confirmation Screen 6.24.4.2 American Standard Sender Calibration If you have a rectangular tank, and a sender with the standard American resistance range (240 ohms full, 33 ohms empty), and you know the capacity of the tank, you can easily calibrate the sender by using the “Set to American Standard (240-33 ohm)”...
DSM570 User’s Manual Figure 196 – European Standard Sender Calibration 6.24.5 Tank Number Next, the tank number must be configured. A tank number can have a value between 0 and 15. Each tank of a particular type must have a tank number that is different from all other tanks of the same type.
keys to position the highlighted cursor over “Tank Type:”, then press the Enter key ( ) to move the highlight to the tank type data itself. Now, use the Scroll Up ( ) or Scroll Down ( ) keys to change the tank type data to the type desired.
DSM570 User’s Manual Figure 199 – Configuring the Operating Mode 6.24.8 Gauge Resistance, + to Sender If the desired operating mode is “NMEA 2000 & Analog Gauge”, the two gauge resistances must be programmed (please refer to the TLA100 User’s Manual for details on how to perform these measurements).
To program the - to sender gauge resistance, use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlighted cursor over the “Gauge Resistance, - to Sender:” menu item. Then, press the ) to move the highlight over the numerical resistance value. Use the “Increase” and Enter key ( “Decrease”...
DSM570 User’s Manual 6.25 Maretron TLM100 Configuration The DSM570 may be used to configure and calibrate the Tank Level Monitor (TLM100 / TLM150 / TLM200). This describes the configuration of firmware version 1.1.6. After selecting the TLM100 from the list of devices on the network, the following screen will be displayed.
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
DSM570 User’s Manual the tank capacity being configured. To program the tank capacity, use the Scroll Up or Scroll Down keys to move the highlighted cursor over the “Tank Capacity:” menu item. Then, press the Enter key to move the highlight over the numerical tank capacity value. Use the Increase and Decrease keys to change the value to the desired tank capacity value, and finally, press the Accept key to confirm your selection.
• Rectangular Tank – By inputting some dimensions of a rectangular tank, the TLM100 is able to interpolate the volume of liquid from the distance to the surface. 6.25.4.1 Custom Calibration The Custom Calibration setting will provide the most accurate tank level readings under any circumstances, but it requires that you go through a process in which you gradually fill the tank, stopping periodically to input the current fluid level.
DSM570 User’s Manual Figure 208 – Tank Levels Calibration Capacity Estimation The next step in the calibration process is to fill the tank and indicate the volume of fluid in the tank at various points while filling the tank. This process should be started with an empty tank. You only need to indicate two calibration points for a rectangular tank and can use up to 16 calibration points for a tank with a more complex shape.
Figure 210 – Intermediate Level Calibration Once the tank is completely full, instead of pressing the Accept key to store the current calibration point, press the Complete key. This will complete the calibration process and will also adjust the tank capacity to the currently indicated level.
DSM570 User’s Manual Figure 212 – Custom Tank Level Calibration Confirmation Screen 6.25.4.2 Rectangular Tank If you have a rectangular tank, and you know the capacity of the tank, you can easily calibrate the sender by using the “Rectangular Tank” menu item. Figure 213 below shows this option highlighted. Use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlight over this menu item, and...
• Reserved-1..Reserved-7 – These values may be used when the contents of the tank does not fit into one of the categories above. 6.26 Maretron TLM150 Configuration The TLM150 is the gasoline version of the TLM100. The configuration of the two devices is the same;...
6.28 Maretron TMP100 Configuration Maretron Temperature Modules (TMP100) may be configured using the DSM570. This describes the configuration of the Maretron TMP100 firmware version 1.1.1. The top level of the TMP100 configuration menu is shown below. Figure 215 – TMP100 Configuration Screen 6.28.1...
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
DSM570 User’s Manual Figure 218 – TMP100 Channel Configuration Screen 6.28.2.1 Instance The Data Instance of the Temperature (as sent in PGNs 130311, 130312, and 130823) is set in this field. Use the Increase and Decrease buttons to select the correct instance number, and the press the Enter button to store it.
6.29 Maretron USB100 Configuration Maretron USB100 gateways on the network may be configured using the DSM570. This describes the configuration of the Maretron USB100 firmware version 1.8.3. The USB100 configuration menu is shown in Figure 219 below. There is one configurable item for the USB100 and that is “Remote Device Selection…”.
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
6.30 Maretron VDR100 Configuration The DSM570 is capable of performing configuration of the VDR100 Vessel Data Recorder. This describes the configuration of the Maretron VDR100 firmware version 2.0.0.4. Figure 222 below shows a screenshot of the VDR100 configuration menu. Figure 222 – VDR100 Configuration Screen 6.30.1...
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
6.31 Maretron WSO100 Configuration The DSM570 is capable of performing configuration of the WSO100 Wind/Weather Sensor. This describes the configuration of the Maretron WSO100 firmware version 2.0.13. Figure 224 below shows a screenshot of the WSO100 configuration menu. Figure 224 – WSO100 Configuration Screen 6.31.1...
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any information you like here, such as the date the unit was installed, or the location in which it was installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later.
from the WSO100, for instance, if you have a separate thermometer / humidity sensor / barometer on the network, it is possible to do so with the DSM570.Pressing the Enter key with “NMEA2000 PGN Enable/Disable…” menu item selected causes the DSM570 to display the following screen (Figure 226).
DSM570 User’s Manual Figure 227 – WSO100 Device Label Menu 6.31.3 Installation Offset Calibration The WSO100 comes from the factory with a preset orientation, so that mounting it with the orientation marks facing the bow of the vessel, the sensor will read 0° apparent wind angle when the vessel is sailing directly into the wind (please refer to the WSO100 User’s Manual for details).
miles/hour. If the apparent wind speed is lower than this, then an error message will appear, which is shown in Figure 229 below, and the calibration process will be aborted. Figure 229 – WSO100 Configuration Aborted Due to Low Wind Speed If the wind speed is sufficient, then a confirmation screen, shown in Figure 230 below, will appear, indicating that a successful installation offset calibration has completed.
DSM570 User’s Manual Figure 231 – Installation Offset Abort Confirmation Screen 6.31.4 Wind Data Damping Period The WSO100 comes from the factory preset with a damping period of 1.5 seconds, which should be appropriate for most applications. However, you may use the DSM570 to tune the damping period to anywhere between 0.1 seconds and 5.0 seconds if you desire.
Figure 233 – Setting the Barometric Pressure Use the Increase and Decrease buttons to select the correct pressure, and the press the Enter button to store it. 6.31.6 Outside Humidity The Humidity is pre-calibrated before leaving the factory and should not require adjustment. However, the current humidity level may be entered in this screen to re-calibrate the WSO100 should this be required.
DSM570 User’s Manual Figure 235 – Setting the Outside Temperature Use the Increase and Decrease buttons to select the correct temperature, and the press the Enter button to store it. Page 204 Revision 1.8.3...
7 Data Display Types 7.1 Anchor Watch Display The Anchor Watch Display is a graphical representation of an Anchor Alert. See Section 8.3.7.9 for details on how to set up the Anchor Alert. Figure 236 – Anchor Watch Display Example The display is centered on the position at which the anchor is dropped;...
DSM570 User’s Manual 4. To exit the control mode, press the “Lights” key to return to normal operating mode. The highlight will disappear. 7.2 Bar Graph The bar graph display shows a parameter on a vertical bar graph with ten segments. The numeric value of the parameter is shown above the bar graph.
DSM570 User’s Manual 7.4 Date The date display shows a date. The format of the date shown can be set using the “Units…” menu (please refer to 5.2.7.13 for details on how to set the date format). A full-screen view of a date display can be seen in Figure 240 below.
7.6 Gauge Display The gauge display shows the selected data in a graphical format resembling an analog gauge. There is a general gauge format for most types of display, and a specialized rudder gauge display. A full- screen example of a tachometer display can be seen in Figure 242 below. Figure 242 –...
DSM570 User’s Manual 7.7 GPS Status Display The GPS Status display shows the following data about the selected GPS receiver: • GPS operating mode (2D, 3D, DGPS) • Satellite signal strength (up to 12 satellites) • Satellite azimuth and elevation (up to 12 satellites) •...
7.8 Half Gauge Display The Half Gauge display shows the selected parameter value in a graphical format resembling a semicircular analog gauge. A full screen example of a half gauge display can be seen in below. Figure 245 – Half Gauge Display Example 7.9 Indicator Light The DSM570 is capable of displaying the state of binary (ON/OFF) sensors on the network with an indicator light display that emulates a status light on a control panel.
DSM570 User’s Manual Figure 246 – Configuration of Indicator Light Display The maximum number of indicator lights you can have on a single screen is 16 (the “4 Quarters” format, with all four windows set to use the “4 rows” or “2 rows, 2 columns” indicator light configurations.
Figure 248 – Configuration of an Individual Indicator Light Each indicator light has several configurable parameters: • Color-Off – select the color to be displayed when the indicator is in the OFF state. The default color is gray. • Color-On – select the color to be displayed when the indicator is in the ON state. The default color is green.
DSM570 User’s Manual Figure 249 – Numeric Display Example The upper left-hand corner indicates the parameter being displayed and the center of the screen shows the numeric value for the indicated parameter. The bottom right hand corner shows the units. Page 214 Revision 1.8.3...
7.11 Numeric/Precision The numeric/precision display shows the selected parameter in a numeric format on the screen, but at a higher resolution (or precision) than the numeric display. A full-screen example of the current depth display can be seen below in Figure 249. Figure 250 –...
DSM570 User’s Manual Figure 251 – Configuration of Rolling Road Display The following data items may be displayed on the rolling road display: • COG (Course Over Ground) • SOG (Speed Over Ground) • BTW (Bearing to Waypoint) • DTW (Distance to Waypoint) •...
Figure 252 – Rolling Road Display 7.13 Line Graph The line graph display shows the value of a parameter displayed on the horizontal axis versus time on the vertical axis. Figure 253 below shows the line graph display for barometric pressure over a time period of one day.
DSM570 User’s Manual Figure 254 – SMS Status Display 7.15 Time (hh:mm) The Time (hh:mm) display shows a time value in an hours and minutes format. Figure 255 below shows an example of this type of display. Figure 255 – Time (hh:mm) Display 7.16 Time (hh:mm:ss) The Time (hh:mm:ss) display shows a time value in an hours, minutes, and seconds format.
Figure 256 – Time (hh:mm:ss) Display 7.17 VDR Status The VDR Status display shows the status of a VDR100 Vessel Data Recorder on the network. The normal state for the VDR is “Recording”. Please refer to the VDR100 User’s Manual for other status that could be displayed on the VDR Status display.
7.19 Wind Rose The DSM570 supports a wind rose display, which displays apparent wind direction and speed measured relative to the moving vessel, or true wind direction and speed measured relative to the moving vessel, depending on the parameter selected. A screen shot of a wind rose appears in Figure 259 below.
DSM570 User’s Manual Figure 261 – SMS Signal Strength Bar Display 7.22 Trim Tabs Bar Graph Display The DSM570 supports a trim tab display in which the relative positions of the port and starboard trim tabs are displayed on a dual bar graph. A screenshot of the trim tab display appears in Figure 262 below.
Figure 263 – Swing Meter Display 7.24 Tank Gauge Display The DSM570 supports a tank level gauge display type which shows percentage of fluid remaining in a tank on an analog gauge with 180° of travel. A screenshot of a tank gauge display showing a fuel tank’s level appears in Figure 264 below.
DSM570 User’s Manual Figure 265 – Watermaker Status Display 7.26 Switch/Breaker Display The DSM570 is capable of controlling loads controlled by a Maretron DCR100 DC Relay, a Carling ® OctoPlex AC Box or DC Box, or other NMEA 2000 load controller which uses NMEA Command of the 127501 Binary Switch Bank Status PGN for control.
The maximum number of switches/breakers you can have on a single screen is 16 (the “4 Quarters” format, with all four windows set to use the “4 rows” or “2 rows, 2 columns” switch/breaker configurations. In order to configure the individual switch/breaker controls, press the “Enter” key with the selected type highlighted to display a menu with entries for each switch/breaker in the window being configured, as shown in Figure 267 below.
Page 242
DSM570 User’s Manual • Type – you may choose between the default value of “Toggle”, in which case the switch/breaker changes state every time you press the power button while it is highlighted, or “Momentary”, in which case the switch-breaker is turned on only while you are pressing the power button while it is highlighted.
DSM570 User’s Manual 8 Alerts The DSM570 can act as both an Alert Source and an Alert Monitor. An Alert Source monitors ® parameters received on the NMEA2000 bus against a user entered threshold, and displays alerts when parameters go out of range. It will also transmit this Alert information to other Alert Monitors on the bus (Platinum copies of N2KView™...
Figure 271 – Alert Status Screen 8.2 Accepting or Cancelling an Alert Active Alerts may be accepted (4.3.2) by the operator to indicate that the operator has taken responsibility for the Alert. Alerts that have been triggered and the cause removed without being accepted by a user must be cleared.
DSM570 User’s Manual Figure 273 – The Alert Detail Screen Pressing the Enter button at this point will Accept or Cancel the Alert. 8.3 Adding an Alert Alerts are created by selecting the parameter to be monitored (e.g. Depth), and then selecting the type of Alert (e.g.
Figure 275 – Part of the Alert Edit Screen This allows the entry of all the alert parameters, which can vary depending on the type of alert chosen. These parameters are: 8.3.1 Enable/Disable Control This allows individual alerts to be enabled or disabled. The decision to disable an Alert must be made very carefully, as it nullifies the purpose for having alerts.
DSM570 User’s Manual 8.3.4 Trigger Source This allows the selection of the parameter to be monitored. The parameters are laid out as per Section 4.2. The trigger source is specified in three parts, which when combined will uniquely identify a single parameter on the bus. 8.3.4.1 Type The Type corresponds to the category of data.
Figure 276 – High Alert Parameters A high alert is triggered (i.e. becomes an active alert) once an input signal has risen above the High Alert Set Point and the Set Delay time has elapsed. If the Set Delay is set to zero, then the alert is immediately triggered once the input signal rises above the High Alert Set Point.
DSM570 User’s Manual Figure 277 – Trigger Configuration – High Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
Figure 278 – Low Alert Parameters A low alert is triggered (i.e. becomes an active alert) once an input signal has dropped below the Low Alert Set Point and the Set Delay time has elapsed. If the Set Delay is set to zero, then the alert is immediately triggered once the input signal drops below the Low Alert Set Point.
DSM570 User’s Manual Figure 279 – Trigger Configuration – Low Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
Figure 280 – Trigger Configuration – Data Unavailable Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
DSM570 User’s Manual 8.3.7.4.1 Trigger Configuration Figure 281 – Trigger Configuration – On Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
8.3.7.5.1 Trigger Configuration Figure 282 – Trigger Configuration – Off Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
DSM570 User’s Manual Figure 283 – Trigger Configuration Editor – Tripped Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
Figure 284 – Outside Alert Parameters 8.3.7.7.2 Trigger Configuration – Outside Radius Alert Figure 285 – Trigger Configuration – Outside Radius Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
DSM570 User’s Manual Alert Clear Delay – The distance between the current GPS position and the reference position must fall below the Outside Radius Alert Clear value for longer than the time in this field in order for an alert to become inactive. Latitude –...
Page 259
Alert Clear Delay – The distance between the current GPS position and the reference position must rise above the Inside Radius Alert Clear value for longer than the time in this field in order for an alert to become inactive. Latitude –...
DSM570 User’s Manual Trigger Configuration – GPS Quality Alert 8.3.7.10.1 Figure 287 – Trigger Configuration – GPS Quality Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
Figure 288 – Direction Alert Parameters Trigger Configuration – Direction Alert 8.3.7.11.1 Figure 289 – Trigger Configuration – Direction Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will stop sounding. If the condition which caused the alert remains true after the amount of time in this field, the alert will return to the “Active”...
DSM570 User’s Manual Offset Clear Point, Offset Clear Delay – If the alert is active and the direction being monitored differs from the reference direction by less than the Offset Heading Clear Point for longer than the time specified in the Clear Delay field, the alert will become inactive. Reference Heading / Reference Direction / Reference Course –...
8.3.9 Tone If Local Audible is enabled, the tone that is sounded on the DSM570 and the Remote Annunciators can be set here. This allows the user to configure the Alerts so that the alert can be identified from the tone.
DSM570 User’s Manual The desired option is selected using the Scroll Up and Scroll Down buttons, and then pressing the Enter button again. The tone of the Annunciator will be the same as that set in 8.3.9. SMS (Text) Settings… 8.3.11 For each alert, you may select up to three phone numbers from the phone book to send an alert message to.
• Send When Triggered – an “Enable” value in this field will cause a SMS text message to be sent to the number in the “Phone Number” field whenever the alert is triggered. A “Disable” value will cause the display to not send a text message to this number in this case. •...
DSM570 User’s Manual • Local – the Alert messages are not transmitted • Global – the Alert messages are transmitted The desired option is selected using the Scroll Up and Scroll Down buttons, and then pressing the Enter button again. 8.4 Deleting an Alert From the Alert Setup Menu, select the menu item Delete Alert…...
A confirmation message is displayed. Figure 296 – Deleting an Alert: Confirmation Press the Accept button to delete the Alert or the Cancel button to return to the previous screen without deleting the Alert. 8.5 Editing an Alert From the Alert Setup Menu, select the menu item Edit Alert… . Figure 297 –...
DSM570 User’s Manual This brings up the list of Alerts managed by the DSM570. Figure 298 – Editing an Alert: Alert List The following information is shown for each alert that is in the system. Priority – The priority of the Alert (see 8.3.3). Enab.
8.7 SMS (Text) Phone Book The display is able to transmit SMS (text) messages via a Maretron SMS100 SMS (Text) Module in the event of an alert. This menu allows you to program up to eight different phone numbers to which the display will send alert messages.
DSM570 User’s Manual Figure 300 – Editing the SMS (Text) Phone Book Once you have pressed “Enter”, the screen will change to display the SMS (Text) Phone Book, as shown in the figure below: Figure 301 – SMS (Text) Phone Book Screen To edit a number in the phone book, press Scroll Up and Scroll Down until the desired entry is highlighted, and then press Enter.
Figure 302 – Phone Number Editing See Section 3.3.4 for details on editing the phone number. Starting the phone number with the international “+” prefix will allow the number to work regardless of what country the phone’s SIM card phone number is registered in. After you have edited the phone number and saved it by pressing Enter a second time after the last digit is entered, you will then be given the chance to edit the name for the phone number as shown in Figure 303 below.
DSM570 User’s Manual Figure 304 – SMS Phone Book Test Message Popup Press “Yes” to send a test message, or press “No” to skip sending the test message. You will be returned to the “SMS (Text) Phone Book…” screen. Once you have created all of the phone book entries you need, press the “Back” key to exit the “SMS (Text) Phone Book…”...
8.8.1 Remote Alert Audible If Remote Alerts are enabled, and an active alert is received from another device on the bus, the DSM570 will respond by adding the Alert to its list of Active Alerts (Section 8.1), and sounding the internal speaker.
DSM570 User’s Manual 9 Maintenance Regular maintenance is important to ensure continued proper operation of the Maretron DSM570. Perform the following tasks periodically: • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corrode the DSM570 enclosure or seals.
Check the Instance Numbers on all devices transmitting that data. If these steps do not solve your problem, please contact Maretron Technical Support (refer to Section 12 for contact information). Warning: There are no user-serviceable components inside the Maretron DSM570. Opening the DSM570 will expose the sensitive electronic components to adverse environmental conditions that may render the unit inoperative.
DSM570 User’s Manual 11 Technical Specifications Specifications Parameter Value Comment ® NMEA 2000 DeviceNet Micro-C Connector Display Technology Active Matrix TFT LCD Sunlight Readable Display Resolution 640 x 480 Pixels VGA Resolution 5.7” Diagonal Display Viewable Area 115.2mm W x 86.4mm H Display Backlighting 3 User-Programmed Levels 0-100% Body Construction...
Page 277
Fuel Management Distance to Empty, Time to Empty, Total Fuel Capacity, Total Fuel Level, Total Fuel Consumption, Total Trip Fuel Used, Total Fuel Economy, Total Fuel Rate, Total Fuel Remaining COG, Lat/Lon, SOG, DOP, Satellites, Time, Accuracy Heading Heading, Rate of Turn, Variation Humidity Inside, Outside, User Defined Indicator...
Page 278
Gen. Phase A AC Basic Quantities 65028 Gen. Total AC Reactive Power 65029 Gen. Total AC Power 065030 Generator Average Basic AC Quantities 065282 Number of Channels (Maretron) 065284 DC Breaker Current (Maretron) 065286 Fluid Flow Rate (Maretron) 065287 Trip Volume (Maretron) 126992...
Page 279
Alert Text (Maretron) 130822 Alert Control (Maretron) 130823 Temperature, High Range (Maretron) 130824 Annunciator (Maretron) 130825 Data Instance/Chan Correlation (Maretron) N/A 130826 Switch Indicator Status (Maretron) 130828 Dometic HVAC Status (Maretron) 130829 Dometic Icemaker Status (Maretron) 130833 Vessel Data Recorder Status (Maretron)
Page 280
DSM570 User’s Manual 130837 Switch Status Timer (Maretron) 130840 Generic Sensor (Maretron) Electrical Parameter Value Comment Operating Voltage 9 V to 30 V DC Voltage Power Consumption (Maximum) 450mA ® Load Equivalence Number (LEN) NMEA 2000 Spec. (1LEN = 50 mA)
DSM570 User’s Manual 12 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the template. 5.59” 5.12” 6.16” Figure 307 – Flush Mounting Template Learn more about marine electronics and navigation on our website.