POWER MIG 215 MP
®
Figure C.8

DUTY CYCLE

RATED OUTPUT
INPUT VOLTAGE DUTY CYCLE AMPS
230 VAC
100%
120VAC
100%
For additional output ratings reference the S35036 rating plate.
The duty cycle is the "on" time (based on a 10 minute interval) the user can
weld with the machine at a specific output without causing a thermal trip.
Example: 30% duty cycle means welding at the specified output for
3 constant minutes and needing 7 minutes of "off" time before
welding again.
INPUT LINE VOLTAGE VARIATIONS
High Line Voltage/ Low Line Voltage — The Power MIG® 215 MP
will operate between 100 and 250 VAC 60Hz.
WIRE FEED OVERLOAD PROTECTION
The Power MIG® 215 MP
features overload protection of the wire
drive motor. If the motor becomes overloaded, the protection
circuitry turns off the wire feed unit. Check for the proper size tip,
liner, and drive rolls, for any obstructions or bends in the gun cable,
and any other factors that would impede the wire feeding. To
resume welding, simply pull the trigger. There is no circuit breaker
to reset.
VOLTS
30%
215 A 24.8 VDC
120 A
20 VDC
40%
105 A 19.25 VDC
80 A
18 VDC
Figure C.9
If the duty cycle of the machine is exceeded, then the machine will
thermally trip and the image shown will be displayed on the user
interface. The machine must cool down before welding can be
performed.