ASSEMBLY AND INSTALLATION continued
Install unit in its operating
position allow sufficient space for
operating personnel. Install the
Load, Unload and Crumb Trays
as shown, making sure the ends
are at least 6" from any vertical
combustible surfaces.
Have an electrician connect input
power to the unit(s) in accordance
with local electrical codes. A
connection terminal block is inside
the left side cavity for models not
provided with a cord and plug set.
HEATING ELEMENTS
Inspect all heating elements in
the unit for breakage. Every unit
is properly tested prior to leaving
the factory, but damage may of
occurred during shipping. If a broken tube is found, do not apply power to the unit. If everything
checks out, Turn on Main Power Switch, Turn both heat controls and conveyor belt speed control to
the maximum setting and check all heater tubes and conveyor for proper operation.
COOLING SYSTEM
After the unit is initially turned on, allow 5 to 8 minutes for the fan cooling system to come on. Once
on, check the air intake area located under the unit and be sure that there is a sufficient flow of air
into the control box. Keep area under the unit clean from obstructions that may result in restricted air
flow to the control box. Restricting the air flow will cause the unit to run hotter then designed, causing
the Hi-Limit to turn unit off. See the Oven Components section on page 7 for control box & Hi-Limit
Reset locations.
FINAL CHECK
If all heaters and conveyor systems are operating properly, switch the master on/off switch to the OFF
position and allow unit to cool, the fan will continue to circulate air, cooling the unit until the internal
temperatures have been decreased.
If a problem is discovered during any of these start-up procedures, immediately switch the master
on/off switch to the OFF position and notify the Star Service Department at (314) 634-6303.
ELECTRICAL CONNECTION
Before making any electrical connection to this unit, check that the power supply is adequate for the
voltage, amperage and requirements stated on the rating plate.
WARNING
A wiring diagram is included herewith.
Disconnect the unit from the power source before installing or removing any parts.
Be absolutely sure that the ground connection for the receptacle is properly wired. Do not connect
equipment to power without proper ground connections. Improper grounding may result in personal
injury or fatality.
DO NOT CUT OR REMOVE THIS PLUG OR GROUNDING PRONG FROM THE PLUG.
CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE DATA
PLATE OF THE UNIT.
WARNING
ADJUSTABLE
HEAT SHUTTERS
LOAD TRAY
OPERATE
CLEAN
CRUMB TRAY
TYPICAL LEFT TO RIGHT CONFIGURATION

UNLOAD TRAY
CRUMB TRAY