6.1 Outdoor Mounting
The heater is meant for stationary mounting in all sit-
uations and should not be suspended from any struc-
ture which may become mobile or from any organic
structures such as trees. Clearances to combustibles
must be maintained in all cases; do not install heat-
ers in a location such as a parking area, where a
vehicle with a painted or non-metallic uppersurface,
FIGURE 15: Critical Hanger Placement (Outdoor Installation)
Typical Outdoor Suspension Details
I-Beam
Beam Clamp
24" (60 cm)
Minimum
Locknut
Fully Closed
Turnbuckle
(Not Included)
Eyebolt
may be parked within the clearances to
combustibles.
The bottom of the combustion air inlet shall not be
less than 12" (30 cm) above a surface which could
support snow, ice, or debris. See Page 17 , Figure 15.
Unistrut
Angle Iron or
Metal Channel
Spring clip or other closed device capable
of supporting at least 75 lbs (33 kg).
SECTION 6: H
I
EATER
NSTALLATION
17