Table of contents Table of contents General information..........................5 1.1 Symbols and signal words....................... 5 Safety instructions............................. 8 Features............................... 12 Installation..............................13 Starting up..............................14 Connections and controls........................16 Operating..............................18 7.1 Manual control..........................20 7.2 Time-controlled operation......................21 7.3 Function in ‘DMX’ mode........................ 22 Technical specifications........................
Page 4
M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Our products and documentation are subject to a process of continuous development. They are therefore subject to change. Please refer to the latest version of the documentation, which is ready for download under www.thomann.de. 1.1 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this document.
Page 6
General information Signal word Meaning DANGER! This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided. WARNING! This combination of symbol and signal word indicates a pos‐ sible dangerous situation that can result in death or serious injury if it is not avoided.
Page 7
General information Warning signs Type of danger Warning – hot surface. Warning - slip hazard. Warning – harmful or irritating substances. Warning – danger zone. M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Safety instructions Safety instructions Intended use This device is intended to be used to produce artificial fog by vaporising fog fluid. Use the device only as described in this user manual. Any other use or use under other operating con‐ ditions is considered to be improper and may result in personal injury or property damage.
Page 9
Safety instructions DANGER! Danger to life due to electric current! A short circuit could lead to a fire hazard and risk of death. Do not modify the mains cable or the plug! In case of isolation damage, disconnect immediately the power supply and arrange repair. If in doubt, seek advice from a qualified electrician. WARNING! Risk of burns from flammable liquids! The use of flammable liquids in the device may cause severe burns and damage to property.
Page 10
Safety instructions CAUTION! Possible respiratory problems due to fog fluid! Fog fluid can lead to respiratory problems in case of prolonged exposure and in certain people. Using unsuitable fluids can generate toxic gases. Do not use any fog fluids other than the ones approved for the device. Any claims for compensation for damages caused by using non-approved fluids are excluded.
Page 11
Safety instructions NOTICE! Risk of fire due to installation of a wrong fuse! Using fuses of a different type than compatible with the device may cause a fire and seriously damage the device. Only use fuses of the same type. Observe the labelling on the device casing and the information in the "Technical data” chapter. NOTICE! Possible staining due to plasticiser in rubber feet! The plasticiser contained in the rubber feet of this product may react with the coating of the floor and cause permanent dark stains...
Features Features This fog machine is suitable for use in clubs, bars, discotheques, on stages as well as for fire drills. Special features of the device: Control via DMX (3 channels) or the removable control panel Suitable for mobile use Large liquid container for the fog liquid M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Installation Installation Unpack and check carefully there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the product against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively.
Starting up Starting up Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards. NOTICE! Data transfer errors due to improper wiring! If the DMX connections are wired incorrectly, this can cause errors during the data transfer.
Page 15
Starting up Connections in DMX mode Connect the DMX input of the device to the DMX output of a DMX controller or another DMX device. Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain.
Connections and controls Connections and controls & Power Output ö INPUT Minutes Seconds TIMER READY Volume Volume OUTPUT Empty Fluid MANUAL 1|2|4|8|1|3|6|1|2 6|2|4|2|5 M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Page 17
Connections and controls 1 Fog nozzle 2 Fog fluid container with screw-cap 3 Carrying handle 4 Main switch and fuse holder 5 [DMX INPUT] | DMX input 6 [DMX OUTPUT] | DMX output 7 [Minutes] | Rotary control to set the interval between two fog blasts 8 [Seconds] | Rotary control to set the duration of a fog blast 9 [Volume] | Rotary control to set the fog amount per blast 10 Thumb screws for attaching the removable control panel...
Damage to the device due to the use of unsuitable fog fluids! Fog fluids not approved by the manufacturer may permanently damage the unit. Only use the fog fluids listed on www.thomann.de and follow their instructions for use. First, make sure the unit is switched off.
Page 19
Operating Turning the unit on NOTICE! Risk of undetected fires in the absence of supervision! There is a general risk of fire when operating the device. If the appliance is left unattended, fires can go undetected and cause great damage. Never operate the device unattended.
Operating Dry-run protection An electronic protection circuit switches off the pump when the fluid container and hose are empty. If the protective circuit is tripped, refill the fog fluid and enable the protective circuit either on the DMX or as follows: Turn device off at main switch.
Operating 7.2 Time-controlled operation The control panel can be detached from the device and used as a wired remote control (see operating elements ). For this purpose, loosen the two thumb screws on the control unit. Turn the control unit off. The green [Output] LED lights up. Use the [Minutes] and [Seconds] rotary controls to set the interval between two fog blasts and the duration of each fog blast.
Operating 7.3 Function in ‘DMX’ mode Setting the DMX address Use the DIP switches of the device to set the desired DMX address between 1 and 512 (see the following figure). DMX Address Set 1 2 3 4 5 6 7 8 9 1|2|4|8|1|3|6|1|2 6|2|4|2|5 1 2 3 4 5 6 7 8 9...
Page 23
Operating DMX channel allocation Channe Value Function Blast volume 0 … 11 no fog blast 12 … 255 fog blast (minimum…maximum) interval between two fog blasts 0 … 10 not lit 10 s 20 s 30 s 40 s … 2450 s Fog blast duration 0 …...
Page 24
Operating Channe Value Function … 245 s M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Technical specifications Technical specifications M-Fog 1000 M-Fog 1500 M-Fog 2500 Heater power 1000 W 1500 W 2500 W Warm-up time approx. 130 s approx. 135 s approx. 150 s Fluid container capacity Fluid consumption 11…36 ml/min 11…39 ml/min 12…60 ml/min Fog output approx.
Page 26
Technical specifications M-Fog 1000 M-Fog 1500 M-Fog 2500 Inrush current 4.24 A 6.7 A 6.7 A Supply voltage 230 V 50 Hz Fuse 5 mm × 20 mm 5 mm × 20 mm 5 mm × 20 mm 6 A, 250 V, slow-blow 8 A, 250 V, slow-blow 12 A, 250 V, slow-blow Degree of protection...
Page 27
Technical specifications Further information M-Fog 1000 M-Fog 1500 M-Fog 2500 DMX control Blast direction Horizontal Horizontal Horizontal Timer remote control On / off remote control Radio remote control Light effect Hanging bracket M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Troubleshooting Troubleshooting In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting: Symptom Remedy The unit does not work Check the mains connection and the main fuse. No response to the DMX controller 1.
Page 29
Troubleshooting If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de. M-Fog 1000, M-Fog 1500, M-Fog 2500 Fog Machine...
Possible damages caused by unsuitable cleaning agents Cleaners not approved by the manufacturer may permanently damage the unit. Only use the fog machine cleaners listed on www.thomann.de and follow their instructions for use. Clean the appliance after every 30 operating hours, or if it was not in use for a longer period of time.
Page 31
Cleaning Fan grids The fan grids of the device must be cleaned of any contamination, such as dust, etc. on a reg‐ ular basis. Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth.
Protecting the environment Protecting the environment Disposal of the packaging mate‐ rial For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling.