Bryant D Series Installation, Start-Up, And Operating Instructions Manual page 39

Deluxe 4-way multipoise fixed-capacity direct-vent condensing gas furnace
Table of Contents

Advertisement

TABLE 8—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT
(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)
AVG GAS
ALTITUDE
HEAT VALUE
RANGE
AT ALTITUDE
(FT)
(BTU/CU FT)
725
750
775
4001
800
825
to
850
875
5000
900
925
950
AVG GAS
ALTITUDE
HEAT VALUE
RANGE
AT ALTITUDE
(FT)
(BTU/CU FT)
700
725
750
775
5001
800
825
to
850
875
6000
900
925
950
975
1000
AVG GAS
ALTITUDE
HEAT VALUE
RANGE
AT ALTITUDE
(FT)
(BTU/CU FT)
650
675
700
6001
725
750
to
775
800
7000
825
850
875
*Orifice numbers shown in BOLD are factory installed.
FOR USE WITH 040 THROUGH 120 SIZE FURNACES ONLY
0.58
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
43
3.7
43
43
3.4
43
44
3.7
44
44
3.5
44
44
3.2
44
45
3.7
45
45
3.5
45
45
3.3
45
45
3.1
45
45
3.0
45
0.58
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
43
3.6
43
43
3.4
43
44
3.6
44
44
3.4
44
44
3.2
44
45
3.6
45
45
3.4
45
45
3.2
45
45
3.0
45
45
2.9
45
45
2.7
45
45
2.6
45
45
2.5
45
0.58
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
42
3.2
42
43
3.6
43
44
3.8
43
44
3.6
44
44
3.3
44
45
3.8
44
45
3.5
45
45
3.3
45
45
3.1
45
45
3.0
45
—39—
SPECIFIC GRAVITY OF NATURAL GAS
0.62
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.8
42
3.2
3.5
43
3.7
3.8
43
3.4
3.6
44
3.7
3.4
44
3.5
3.8
44
3.3
3.6
45
3.7
3.4
45
3.5
3.2
45
3.3
3.1
45
3.2
SPECIFIC GRAVITY OF NATURAL GAS
0.62
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.7
42
3.2
3.5
43
3.6
3.7
43
3.4
3.5
44
3.6
3.3
44
3.4
3.7
44
3.2
3.5
45
3.6
3.3
45
3.4
3.1
45
3.3
3.0
45
3.1
2.8
45
2.9
2.7
45
2.8
2.5
45
2.6
SPECIFIC GRAVITY OF NATURAL GAS
0.62
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.3
42
3.4
3.7
43
3.8
3.4
43
3.6
3.7
44
3.8
3.4
44
3.6
3.2
44
3.3
3.7
45
3.8
3.4
45
3.6
3.2
45
3.4
3.1
45
3.2
(Continued)
0.64
0.66
Orifice
Manifold
Orifice
No.
Pressure
No.
42
3.3
42
43
3.8
42
43
3.5
43
44
3.8
43
44
3.6
44
44
3.4
44
44
3.2
44
45
3.6
45
45
3.4
45
45
3.3
45
0.64
0.66
Orifice
Manifold
Orifice
No.
Pressure
No.
42
3.3
42
43
3.7
43
43
3.5
43
44
3.7
43
44
3.5
44
44
3.3
44
45
3.8
44
45
3.6
45
45
3.4
45
45
3.2
45
45
3.0
45
45
2.9
45
45
2.7
45
0.64
0.66
Orifice
Manifold
Orifice
No.
Pressure
No.
42
3.5
42
42
3.2
42
43
3.7
43
43
3.4
43
44
3.7
44
44
3.4
44
44
3.2
44
45
3.7
45
45
3.5
45
45
3.3
45
Manifold
Pressure
3.4
3.2
3.7
3.4
3.7
3.5
3.3
3.8
3.6
3.4
Manifold
Pressure
3.4
3.8
3.6
3.4
3.6
3.4
3.2
3.7
3.5
3.3
3.1
2.9
2.8
Manifold
Pressure
3.6
3.3
3.8
3.5
3.8
3.5
3.3
3.8
3.6
3.4