Page 1
Use and Care Guide Gen 1 SERIES Gen 1 LPG 1000517...
Page 3
A qualified installer or service technician must perform equipment installation or service. Contact Aqua-Hot for Factory Authorized Service Centers or Certified technicians located near you at www.airxcel.com/rv/eu/heating-systems, or call us at +39 0424 1953311. • Warranty work must be performed by an Aqua-Hot Factory Authorized Service Center.
Caution Notes Contents Caution Notes As you read this information, take particular note of the NOTICE, Caution Notes ............2 CAUTION, WARNING, and DANGER symbols when they appear. Safety Features ............3 This information is important for safe and efficient use of the Aqua-Hot system.
NOTE: Contact your Authorized Service Center or Aqua- Hot Heating Systems if you have any questions before starting installation. Information can be found online at https://airxcel.eu. All vehicle installations must comply with national legislation and regulations. The gas system must be installed with EN- 1949.
Page 6
Safety Instructions Safe Operation General Care The Aqua-Hot Heating system consists of an electric • To maintain the Aqua-Hot at its full potential, it is highly heating element and a propane burner. The heater recommended to have the burner serviced once a year: with supplementary indirect water heating is for use •...
System Features System Features The Aqua-Hot Gen 1 Heater is a Heating System that can provide interior heat and hot water using a built-in electric heating element and a propane burner. There are three options for heating: • Fuel Mode: the heater automatically adjusts power according to temperatures.
Operational Overview Operational Overview Energy Setting The Aqua-Hot Gen 1 heater has three available energy sources: Fuel, Electric and Hybrid. When “Gas” is selected in the energy setting menu the heater will use on-board fuel to generate heat. Electric In the energy setting menu, EL1 or EL2 can be selected. EL1 activates 900W of electric heating elements.
Operating the LCD Operating the LCD Power ON: Hold the rotary button for 3seconds to turn on LCD. After a few seconds, the time is displayed as 00:00. Click the rotary button to display the initial options in the display. Clock setting (current time setting) •...
Page 11
Operating the LCD Shutdown Press the rotary button for more than 3s at the initial interface to shut down. When the LCD switch is turned off, the heating process and any connected equipment are also automatically turned off. The parameters before shutdown are retained. Adjustment of Interior Temperature •...
Page 12
Operating the LCD .This icon will flash until the predetermined water Heating Start temperature is reached. After the setting is finished, press the return key or wait for 10s to enter the clock interface, and the heating starts. The clock In the "heating and hot water mode", the water temperature and set temperature are displayed alternately.
Page 13
Operating the LCD Enter the End Time Select Fan Speed Level • Use the rotary button to set the end time. • Use the rotary button to set the desired fan speed • Click the rotary button to confirm and proceed to the next •...
Page 14
Operating the LCD Voltage Inquiry Switching Temperature Units • Click the rotation button to display the voltage: 12.0V. Use the knob to switch between Celsius and Fahrenheit, then click to confirm Air Pressure and Temperature Inquiry • Click the rotation button to select the at ATMOS icon. •...
Page 15
Operating the LCD Software Version Number Fault Display • Use the rotary button to select the INDEX icon and click the rotary button to enter the query item. • Use the rotary button to select the icon and click the •...
Aqua-Hot Layout NOTE: The illustration below is just a sample for the layout of the Aqua-Hot heating system. Actual placement may vary on the individual design of the RV. For questions or assistance, contact us at +39 0424 1953311. Heater Installation Layout (RV) 1.
Maintenance & Storage Maintenance & Storage It is recommended to have the system serviced once a year - generally before the heating season: If the information in this manual is not followed • Air inlet and outlet are not blocked or damaged exactly, a fire or explosion may result, causing property •...
Winterization Winterization Disinfecting the Domestic Water System To avoid freeze damage to the system, the heater must be drained through the drain valve completely. If water is left in the system in below freezing temperatures, it can cause severe damage to the system that is not covered under warranty. The Aqua-Hot Heating components are not compatible to NOTE: The Aqua-Hot can continue to be used for interior heat prolonged exposure to sodium hypochlorite (bleach or liquid...
General Troubleshooting Troubleshooting • Ensure that the system is supplied with electrical power and there are no blown fuses. • Make sure all the electrical and plumbing connections are connected and secure. • Ensure there are no faults on the LCD. If there are, determine the fault and remedy. Refer to the table below for the fault code. Fault Codes Error Fault Name...
For additional information, or to obtain a warranty repair authorization, please contact the Aqua-Hot Heating Systems Warranty Administrator at +39 0424 1953311 (08:00 to 16:00 CET Monday through Friday) or visit www.airxcel.com/rv/eu/heating-systems. My Comfort Zones are On-Board Vehicle:...
Page 24
Use and Care Guide Gen 1 SERIES Gen 1 LPG 1000517 AIRXCEL EUROPE - CAN S.R.L. Via G. Apollonio 11 36061 Bassano Del Grappa - (VI) Italy Visit us online at https://airxcel.eu Tel +39 0424 1953311 Fax +39 0424 1953399...
Need help?
Do you have a question about the Aqua-Hot Gen1 Series and is the answer not in the manual?
Questions and answers