7.3. Demand Response

This product is designed to be compatible with Air Conditioning Demand
Response program.
To utilize the function, you need a separate arrangement with your
electricity supplier. Check availability in the place of use.
When your electricity supplier activates one of the following 3 Demand
Response (DR) modes, the air conditioner switches over to the
appropriate operation.
During the DR mode, [ ] indicator on the indoor unit will blink.
Blinking pattern and the intervals are as follows:
Operation mode
Auto/Cooling/Heating/Dry/Fan
10˚C Heat operation
When the DR mode fi nishes, the air conditioner returns to the operation
set before entering the DR mode.
■ Details on Demand Response mode
DR mode
Description of operation in this mode
DR mode 1
Compressor off .
electrical energy consumption in 30 minutes:
DR mode 2
50 % or less
(compared with rated energy consumption)
electrical energy consumption in 30 minutes:
DR mode 3
75 % or less
(compared with rated energy consumption)
NOTES:
• During the DR mode, the cooling or heating performance may be
reduced.
• During the DR mode, only the following operations are valid.
- Turning off the operation by the remote controller
- Off timer operation
• During the DR mode, the Filter sign will not display.
• Timer setting error indicator will be prioritized over the DR mode
indicator.
If you have operational issues:
(1) Contact your electricity supplier to check whether they are activating
the DR mode.
(2) Is the air conditioner under the Demand controlling?
Yes
Contact your electricity supplier.
No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to
your warranty card.)
or
• Visit our website (www.fujitsugeneral.com.au).
En-5
Indicator lamp blinking pattern
On
Blinks (2 times)
Off
Blinks (2 times)

8. OTHER OPERATIONS

8.1. 10 °C Heat operation
10 °C Heat operation maintains the room temperature at 10 °C
so as to prevent the room temperature to drop too low.
- When activated, [
] indicator on the indoor unit will turn on.
- When deactivated, [
] indicator will turn off .
NOTES:
• During the 10 °C Heat operation, only the up/down airfl ow setting is
valid.
• When the room temperature is warm enough, This operation will not
be performed.
• In the multi-split type air conditioner, the room temperature will rise
higher than 10 °C if the other indoor units operate at Heating mode.
When using the 10 °C Heat operation, we recommend that setting
all indoor units at 10 °C Heat operation.

9. CLEANING AND CARE

• Before cleaning the indoor unit, be sure to turn it off
and disconnect all the power supply.
• The fan operates at high speed inside the unit, and
could result in personal injury.
• Be careful not to drop the intake grille.
• If the fi lter cleaning involves high-place work, consult
the professional technical service personnel.
• Do not expose the indoor unit to liquid insecticides or
hair sprays.
• Do not stand on slippery, uneven or unstable surfaces
when you maintain the unit.
The indoor unit's intake grille can be removed for easy cleaning
and maintenance.
When cleaning the unit, do not use water hotter than 40°C,
harsh abrasive cleansers, or volatile agents like benzene or
thinner.