Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System TABLE OF CONTENTS Important Safety Instructions Product Descriptions Unpacking and Installation Instructions Oven Start-Up Care and Cleaning Troubleshooting Wiring Schematic...
• A minimum clearance of 6″ (152,4 mm) from the top of the unit to the ceiling must be provided. • The IVS must be properly attached to the Duke oven that is secured to building structure (Restraining Device Kit).
Page 4
FlexBake 5™ Integrated Ventilation System IMPORTANT SAFETY INSTRUCTIONS (continued) • Turn the FlexBake 5™ Control Power Switch off and disconnect external all poles mains supply then allow unit to cool down before performing any service or maintenance on the unit. •...
Owner’s Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System PRODUCT DESCRIPTIONS SHIPPING WEIGHT: 164 Lbs. Crated SHIPPING DIMENSIONS: 40.539” x 37.085” x 14.210” Carton Size 45.500” x 42.250” x 21.460” Crated Size MODEL NUMBER IVS-CE-FB5 ELECTRICAL Motor: 230VAC / 50-60HZ, 0.39-0.43A...
Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System UNPACKING AND INSTALLATION INSTRUCTIONS TOOLS REQUIRED (NOT PROVIDED) FOR THIS INSTALLATION • Hammer • #2 Phillips Screwdriver • Crowbar/Pry Bar • 5/16” Nut Driver • Knife or Box Cutter...
Page 7
TASKS MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN OR ELECTRICIAN. a. Turn the FlexBake 5™ Control Power Switch off and disconnect external all poles mains supply. b. Remove the façade cover by removing the 16 (#8-32) screws from the top and the 4 (#8-32) screws from...
Page 8
Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System c. Remove the 6 screws (Tek Screws). SAVE SCREWS. d. Disconnect the façade cooling fan and carefully lift the façade off of the oven and save for potential future use (if desired).
Page 9
Owner’s Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System STEP 3: REMOVE THE MOTOR SHIELD a. Remove the 4 screws (#10-24) securing the Exhaust Duct Extension. b. Remove the Exhaust Duct Extension and both gaskets and save for potential reuse with the façade, if desired.
Page 10
Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System STEP 4: INSTALL THE IVS ASSEMBLY a. Place the new Exhaust Duct Gasket b. Carefully set the IVS assembly on top of the oven (supplied with the IVS assembly) onto the aligning the IVS duct with the oven Exhaust Duct Exhaust Duct flange.
Page 11
Owner’s Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System e. Connect the IVS assembly cooling fan f. Connect the IVS assembly blower motor to the (mounted on side wall)(disconnected in Step. oven harness. 2C). IVS Blower Motor IVS Assembly Cooling Fan Oven Conv.
Page 12
Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System STEP 5: INSTALL THE IVS COVER AND EXHAUST RING a. Place the IVS blower adaptor gasket on to b. Locate the IVS Cover in position as shown. Do the adaptor outlet, as shown.
Page 13
This oven appliance must be secured to building structure. A restraining device kit (#153586) was provided with the FlexBake 5™ unit to limit the movement of the appliance without depending on or transmitting stress to the electrical conduit. Installation instruction is in the kit.
Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System OVEN START-UP WARNING ELECTRICAL SHOCK HAZARD. TASKS MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN OR ELECTRICIAN. a. Have a qualified service technician or electrician connect the oven to the power supply.
Owner’s Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System TROUBLESHOOTING There are no user serviceable parts on the Duke IVS. If there is a malfunction, contact your Duke Manufacturing authorized service agent or call 1-800-735-3853. WIRING SCHEMATIC Oven Conv.
Page 16
Owner's Manual and Installation Instructions for FlexBake 5™ Integrated Ventilation System Duke Manufacturing Co. 2305 N. Broadway St. Louis, MO 63102 Phone: 314-231-1130 Toll Free: 1-800-735-3853 Fax: 314-231-5074 www.dukemfg.com...