Fujitsu ARU18RGLX Design & Technical Manual page 9

Hide thumbs Also See for ARU18RGLX:
Table of Contents

Advertisement

Type
Model name
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°FDB/67°FWB (26.67°CDB/19.44°CWB), and outdoor temperature of 95°FDB/75°FWB (35°CDB/23.9°CWB).
– Heating: Indoor temperature of 70°FDB/60°FWB (21.11°CDB/15.56°CWB), and outdoor temperature of 47°FDB/43°FWB (8.33°CDB/6.11°CWB).
1
– *
: Heating (17°F): Indoor temperature of 70°FDB/60°FWB (21.11°CDB/15.56°CWB), and outdoor temperature of 17°FDB/15°FWB (-8.33°CDB/-9.44°CWB).
2
– *
: Heating (5°F): Indoor temperature of 70°FDB/60°FWB (21.11°CDB/15.56°CWB), and outdoor temperature of 5°FDB/4°FWB (-15.0°CDB/-15.56°CWB).
– Test conditions are based on AHRI 210/240 2023.
– Pipe length: 24 ft 7 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
– Standard static pressure: 0.23 inWG (57 Pa)
• Protective function might work when using it outside the operation range.
3
• *
: Maximum current:
– The maximum value when operated within the operation range.
– The total current of indoor unit and outdoor unit.
4
• *
: Sound pressure level:
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
M condition
Model name
Cooling
47°FDB
Capacity
(Outdoor temp.)
Heating
17°FDB
(Outdoor temp.)*
Cooling
47°FDB
(Outdoor temp.)
Heating
17°FDB
Input power
(Outdoor temp.)*
Fan
Cooling
Current
Heating
EER
Cooling
COP
Heating
SEER
Cooling
HSPF
Heating
Cooling
Power factor
Heating
NOTES:
Specifications are based on the following conditions:
• Cooling: Indoor temperature of 80°FDB/67°FWB (26.67°CDB/19.44°CWB), and outdoor temperature of 95°FDB/75°FWB (35°CDB/23.9°CWB).
• Heating: Indoor temperature of 70°FDB/60°FWB (21.11°CDB/15.56°CWB), and outdoor temperature of 47°FDB/43°FWB (8.33°CDB/6.11°CWB).
• *: Heating (17°F): Indoor temperature of 70°FDB/60°FWB (21.11°CDB/15.56°CWB), and outdoor temperature of 17°FDB/15°FWB (-8.33°CDB/-9.44°CWB).
• Test conditions are based on AHRI 210/240 2017.
• Pipe length: 24 ft 7 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Standard static pressure: 0.23 inWG (57 Pa)
kW
Rated
Btu/h
kW
Min.—Max.
Btu/h
kW
Rated
Btu/h
kW
Min.—Max.
Btu/h
kW
Rated
Btu/h
1
kW
Max.
Btu/h
Rated
Min.—Max.
Rated
kW
Min.—Max.
Rated
1
Max.
HIGH
MED
W
LOW
QUIET
Rated
A
kW/kW
Btu/hW
kW/kW
Btu/hW
Btu/hW
kW/kW
- 5 -
Duct
Inverter, Heat pump
ARU36RGLX
ARU36RGLX
10.55
36,000
2.81—11.43
9,600—39,000
10.55
36,000
2.70—14.07
9,200—48,000
6.74
23,000
10.8
36,800
3.6
0.7—4.0
2.88
0.62—4.38
2.52
5.01
158
94
59
40
15.8
12.6
2.93
10.0
3.66
12.5
16.7
11.3
99.1
99.4
1. Specifications