• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
– Heating: Indoor temperature of 70°FDB (21.11°CDB)/59°FWB (15°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
– Pipe length: 24 ft 6 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *: Sound pressure level
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
A
Cooling
3
CFM (m
/h)
Heating
W
Cooling
dB (A)
Heating
Dimensions
in (mm)
(H × W × D)
Fin pitch
FPI
Rows × Stages
Pipe type
Type (Material)
Fin
Surface treatment
W
Type
lb oz
Charge
g
Type
3
3
Amount
in
(cm
)
Material
Color
in (mm)
in (mm)
lb (kg)
Liquid
in (mm)
Gas
ft (m)
Cooling
°F (°C)
Heating
in (mm)
Inverter, Heat pump
AOU18RGLX
AOU24RGLX
208/230 V~ 60 Hz
6.6
9.6
1,177 (2,000)
1,489 (2,530)
47
50
31-7/16 × 35-7/16 × 1-7/16 (798 × 900 × 36.4)
Approximate color of Munsell 10YR 7.5/1.0
32-11/16 × 35-7/16 × 13 (830 × 900 × 330)
39-3/8 × 41-5/16 × 17-1/2 (1,000 × 1,050 × 445)
Ø1/4 (6.35)
Ø1/2 (12.70)
-5 to 115 (-21 to 46)
-5 to 75 (-21 to 24)
Ø1/2 (13.0) (I.D.), Ø5/8 to Ø11/16 (Ø16.0 to Ø16.7) (O.D.)