INSTALLATION, OPERATION AND MAINTENANCE MANUAL
RADIANT INFRARED ELECTRIC HEATER
BIG ASS FANS OBSIDIAN® ELECTRIC HEATER
MODELS
VOLTAGE
TOTAL POWER (W)
CURRENT(AMPS)
BAFC60240B
208/240
4500/6000
21.6/25
FIRE/EXPLOSION HAZARD WARNING
NOT FOR USE IN HAZARDOUS OR EXPLOSIVE ATMOSPHERES
During operation, always ensure combustible materials are kept at a safe distance from the heater
body and from the emitted radiant energy. This heater is not intended for use in hazardous areas where
flammable vapours, gases, liquids or other combustibles are present. Failure to do so can result in
personal injury/or property damage.
FOR OUTDOOR RESIDENTIAL AND INDOOR OR OUTDOOR COMMERCIAL USE
BIG ASS FANS dba DELTA T LLC
2348 INNOVATION DR. LEXINGTON KY 40511
PHONE: 877.BIG.FANS
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the OBSIDIAN BAFC60240B and is the answer not in the manual?

Questions and answers

Summary of Contents for BIG ASS FANS OBSIDIAN BAFC60240B

  • Page 1 Failure to do so can result in personal injury/or property damage. FOR OUTDOOR RESIDENTIAL AND INDOOR OR OUTDOOR COMMERCIAL USE BIG ASS FANS dba DELTA T LLC 2348 INNOVATION DR. LEXINGTON KY 40511 PHONE: 877.BIG.FANS...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1 - SAFETY ................................3 2 - INSTALLATION INSTRUCTIONS .......................... 5 3 - OPERATING INSTRUCTIONS ..........................10 3.1.1 Operation of the Remote Control ....................10 4 - MAINTENANCE ..............................11 WARNINGS THIS ELECTRIC APPLIANCE PRODUCES INFRARED HEAT, FAILURE TO FOLLOW WARNINGS AND INSTRUCTIONS CAN CAUSE FIRE, ELECTRIC SHOCK, OR INJURY.
  • Page 3: Safety

    IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following outlined in section 1 – SAFETY. Read all instructions before installing or using this heater. This heater must be used strictly according to these instructions. 1 - SAFETY WARNINGS WARNING: FIRE OR EXPLOSTION HAZARD...
  • Page 4 WARNING: PERSONAL INJURY HAZARD - CLEANING AND MAINTENANCE • • To avoid property damage, personal injury Before cleaning the unit or replacing the or death due to electrical shock DO NOT emitter, turn off the main power. Make sure service the unit without turning the unit the heater and/or the emitter is cool before OFF and disconnecting the heater from the handling.
  • Page 5: Installation Instructions

    2 - INSTALLATION INSTRUCTIONS Heater installation must be carried out by qualified personnel in compliance with local National Codes (NEC) as well as any other applicable standards. Failure to comply with applicable requirements could result in personal injury and/or property damage. Wiring procedures and connections shall be made in accordance with national and local electrical codes having jurisdiction.
  • Page 6 Ceiling Suspended Minimum Clearances FIRE HAZARD! HEATER MUST NEVER BE POINTED TOWARDS WALLS OR CEILINGS ELECTRICAL INSTALLATION Safety Precautions 1. Each power supply circuit must be properly grounded. 2. Use a certified ground fault protection device for wet environment installations. 3.
  • Page 7 short part of the bracket. Brackets should be Follow local and national electrical code attached as shown below. NOTE: Wall bolts or requirements. anchors are not supplied. Select an appropriate size to provide adequate support for the weight of the unit and taking into consideration any wind load conditions.
  • Page 8 Select the installation location on the ceiling by of the bolt pattern dimensions is shown to the identifying the studs or structural beams that right. will allow the heater to be securely attached. NOTE: ceiling bolts or anchors are not supplied. The heater can be hung vertically or pointed at Select an appropriate size to provide adequate a maximum angle of 45°...
  • Page 9 ADJUSTING DIRECTIONAL POSITIONING Never attempt to move or adjust the heater angle while it is running. Personal WARNING injury could result. 1. Turn off the heaters electrical supply line from the main power supply. 2. Allow the heater to cool before adjusting the angle. 3.
  • Page 10: Operating Instructions

    3 - OPERATING INSTRUCTIONS Caution! The heater must be properly installed before it is used. REMOTE CONTROL The remote control must be pointed in the direction of the receiver on the heater junction box. (located on the right side of the heater). The remote must be in line of sight of the domed receiver when the user intends to adjust the power level.
  • Page 11: Maintenance

    3. The remote-control function may not work if there is a barrier between the remote control and heater. Replace the batteries as required to ensure correct remote functionality. 4 - MAINTENANCE WARNINGS 1. Allow the heater and the emitter to cool down before handling. Installation and maintenance must be performed by a qualified technician.
  • Page 12 1. WARNING! TURN OFF THE POWER AND Caution! Disconnect metal locking DISCONNECT THE HEATER FROM THE MAIN connectors by squeezing the metal tab. POWER SUPPLY. FAILURE TO DISCONNECT HEATER BEFORE REPLACING THE EMITTER COULD CAUSE ELECTRIC SHOCK OR DEATH! 2. Turn OFF the power and disconnect from main power supply.
  • Page 13 Carefully replace the protective aluminum grille and screw the protective end cap in place. Due to ongoing product improvements, specifications and dimensions are subject to change and correction without notice and without incurring obligations. Determining the application and suitability for use of any product is the responsibility of the installer.
  • Page 14 BIGASSFANS.COM/PRODUCT-WARRANTIES...