Download Print this page
BIG ASS FANS OBSIDIAN BAFC30240B Installation, Operation And Maintenance Manual
BIG ASS FANS OBSIDIAN BAFC30240B Installation, Operation And Maintenance Manual

BIG ASS FANS OBSIDIAN BAFC30240B Installation, Operation And Maintenance Manual

Radiant infrared electric heater

Advertisement

Quick Links

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
RADIANT INFRARED ELECTRIC HEATER
BIG ASS FANS OBSIDIAN® ELECTRIC HEATER
MODELS
VOLTAGE
TOTAL POWER (W)
CURRENT(AMPS)
BAFC30240B
208/240
2250/3000
10.8/12.5
FIRE/EXPLOSION HAZARD WARNING
NOT FOR USE IN HAZARDOUS OR EXPLOSIVE ATMOSPHERES
During operation, always ensure combustible materials are kept at a safe distance from the heater
body and from the emitted radiant energy. This heater is not intended for use in hazardous areas where
flammable vapours, gases, liquids or other combustibles are present. Failure to do so can result in
personal injury/or property damage.
FOR OUTDOOR RESIDENTIAL AND INDOOR OR OUTDOOR COMMERCIAL USE
BIG ASS FANS dba DELTA T LLC
2348 INNOVATION DR. LEXINGTON KY 40511
PHONE: 877.BIG.FANS
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the OBSIDIAN BAFC30240B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BIG ASS FANS OBSIDIAN BAFC30240B

  • Page 1 Failure to do so can result in personal injury/or property damage. FOR OUTDOOR RESIDENTIAL AND INDOOR OR OUTDOOR COMMERCIAL USE BIG ASS FANS dba DELTA T LLC 2348 INNOVATION DR. LEXINGTON KY 40511 PHONE: 877.BIG.FANS...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1 - SAFETY ................................3 2 - INSTALLATION INSTRUCTIONS .......................... 5 3 - OPERATING INSTRUCTIONS ..........................9 3.2.1 Operation of the Remote Control ....................10 4 - MAINTENANCE ..............................11 WARNINGS THIS ELECTRIC APPLIANCE PRODUCES INFRARED HEAT, AND FAILURE TO FOLLOW WARNINGS AND INSTRUCTIONS CAN CAUSE FIRE, ELECTRIC SHOCK, OR INJURY.
  • Page 3: Safety

    Notice: Changes or modifications not approved by the party responsible for compliance will void the user's authority to operate the equipment. IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following outlined in section 1 –...
  • Page 4 WARNING: PERSONAL INJURY HAZARD - CLEANING AND MAINTENANCE • • To avoid property damage, personal injury Before cleaning the unit or replacing the or death due to electrical shock DO NOT emitter, turn off the main power. Make sure service the unit without turning the unit the heater and/or the emitter is cool before OFF and disconnecting the heater from the handling.
  • Page 5: Installation Instructions

    2 - INSTALLATION INSTRUCTIONS Heater installation must be carried out by qualified personnel in compliance with local National Codes (NEC) as well as any other applicable standards. Failure to comply with applicable requirements could result in personal injury and/or property damage. Wiring procedures and connections shall be made in accordance with national and local electrical codes having jurisdiction.
  • Page 6 Ceiling Suspended Minimum Clearances ELECTRICAL INSTALLATION Safety Precautions 1. Each power supply circuit must be properly grounded. 2. Use a certified ground fault protection device for wet environment installations. 3. Use a proper electrical connection box 4. Supply voltage and frequency must correspond to the electrical rating indicated on unit’s information plate...
  • Page 7 WALL-MOUNTED INSTALLATION THE CF30240B HEATER MUST BE INSTALLED WITH BOTH MOUNTING BRACKETS PROVIDED IN THE BOX. 1. Take the heater out of the box and remove all short part of the bracket. NOTE: Wall bolts or protective foam inserts. anchors are not supplied. Select an appropriate size to provide adequate support for the weight 2.
  • Page 8 CEILING MOUNTED INSTALLATION Heater should be hung using rigid mounting brackets, the unit must not be able to swing in any direction under applied load from wind or persons. It is highly recommended that users install the heater with the WARNING ceiling mounting hardware provided.
  • Page 9: Operating Instructions

    ADJUSTING DIRECTIONAL POSITIONING Never attempt to move or adjust the heater angle while it is running. Personal WARNING injury could result. 1. Turn off the heaters electrical supply line from the main power supply. 2. Allow the heater to cool before adjusting the angle. 3.
  • Page 10: Operation Of The Remote Control

    MANUAL MODE When the manual mode is selected, the heater will operate at 100% of rated power. REMOTE MODE The remote control must be pointed in the direction of the receiver on the heater body (located on the front face) and must be used within a maximum distance of 6 m. In remote mode the heater has 6 power levels.
  • Page 11: Maintenance

    Notice: 1. Use 2 pieces AAA, 1.5V batteries (not included) in the remote control. Remove the batteries when not in use for an extended period of time to increase battery life. 2. The heater can be still used normally in the event the remote control is misplaced, however it must be used in manual mode.
  • Page 12 REPLACING THE EMITTER Contact your distributor for the correct replacement emitter, providing the model number and rating from the rating label. Using an incorrect replacement emitter can cause the heater to fail. Notice: Read through the Emitter replacement procedure below before beginning the replacement. For easier replacement, remove the heater from the wall or ceiling.
  • Page 13 9. Insert the new emitter through the reflector 10. Connect the new emitter to the terminals of openings. Insert the Reflector Shields and bend the heater; screw in the protective plastic caps the tabs back into place. The Reflector Shields hold the emitter in the correct position during operation.
  • Page 14 BIGASSFANS.COM/PRODUCT-WARRANTIES...