CAME 806LA-0060 Manual page 21

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 18
W jumper settings
F - Flashing
The fl ashing beacon fl ashes automatically when the board is powered up.
S - Stable
The beacon follows the trend of the power supply from the panel. It remains on when the
panel supplies steady power and fl ashes when the panel supplies intermittent power.
Operators and barriers (LT4)
Connect terminals 24-W on the fl ashing beacon to terminals 10-E/E1 on the control
panel.
Set the jumper (W) as shown in fi gure. This is so that the LEDs will fl ash independently
when the control panel is powered up.
Up-and-over models (VER PLUS)
Connect terminals 24-R-G on the beacon to terminals 10-E-5 on the control panel.
Set the jumpers (R) and (G) as shown in the fi gure.
The beacon can be confi gured in traffi c light or GGR mode by setting the F18 function
parameter on the control panel.
The F10 function is automatically disabled.
Function
Traffi c
light
GGR
The beacon only works on VER PLUS gearmotor control boards version 1.8.0 or
later. Update the board fi rmware if necessary.
O
Barriers (LS4)
Connect terminals 24-R-G on the beacon to terminals +-R-G on the control panel.
Set the jumpers (R) and (G) as shown in the fi gure.
M
N
F18 function
parameter
F18=3
F18 = 4
LED
Red fl ashing
Green on
Flashing green
Green on
Red fl ashing
Door status
Door moving
Door open
Door opening
Door open
Door closing

Advertisement