Download Print this page

New Holland ZDJE10095 Service Manual page 11

Advertisement

Note to the Owner WARNINGS FOR AIR CONDITIONING SYSTEM
REPAIR OPERATIONS
T4.105V With cab [ZDJE17896 - ]
T4.75V With cab [ZDJE10095 - ]
T4.85V With cab [ZDJE11669 - ]
T4.95V With cab [ZDJE11682 - ]
Starting the system at low temperatures can damage the compressor. Only operate the air conditioner when the
engine is hot and the temperature inside the cab is at least 20 °C (68.00 °F).
When disconnecting the hoses, close the ends with plastic caps to prevent foreign matter and humidity from getting
inside the hoses.
Handle the thermostatic sensor carefully to avoid damage that may prevent efficient system operation.
Always use two spanners to unscrew the hose fittings to avoid twisting the fitting.
Do not use any type of engine oil to lubricate the compressor and the system.
Never leave the compressor oil container open, always make sure that it is tightly closed. If left exposed the oil will
absorb humidity from the air and may, subsequently, damage the system.
Do not transfer compressor oil from the original container to another container.
Do not introduce any additives to the compressor oil. Any additional substances could contain elements which are
incompatible with the chemical base of the refrigerant and thus alter its characteristics.
Check that the thermostatic sensor is correctly inserted in the fins on the evaporator to ensure efficient system oper-
ation.
INTRODUCTION
NA
NA
NA
NA
47888375 08/07/2016
4

Advertisement

loading