Safety Information
• Upon receipt, inspect the product to verify that it has not been
damaged during transport. If the product appears damaged,
DO NOT INSTALL it and immediately report the damage to the
carrier or retailer (if the installer or the authorized technician
has collected the material from the retailer.)
• After completing the installation, always carry out a
functional test and provide the instructions on how to
operate the air conditioner to the user.
• Do not use the air conditioner in environments with
hazardous substances or close to equipment that release
free flames to avoid the occurrence of fires, explosions or
injuries.
• Our units should be installed in compliance with the spaces
shown in the installation manual, to ensure accessibility
from both sides and allow repairs or maintenance
operations to be carried out. The unit's components should
be accessible and easy to disassemble without endangering
people and objects.
For this reason, when provisions of the installation manual
are not complied with, the cost required to access and
repair the units (in SAFETY CONDITIONS, as set out in
prevailing regulations) with harnesses, ladders, scaffolding
or any other elevation system will NOT be considered part
of the warranty and will be charged to the end customer.
Power supply line, fuse or circuit
breaker
WARNING
• Always make sure that the power supply is compliant
with current safety standards. Always install the air
conditioner in compliance with current local safety
standards.
• Always verify that a suitable grounding connection is
available.
• Verify that the voltage and frequency of the power
supply comply with the specifications and that the
installed power is sufficient to ensure the operation of
any other domestic appliance connected to the same
electric lines.
• Always verify that the cut-off and protection switches
are suitably dimensioned.
• Verify that the air conditioner is connected to the power
supply in accordance with the instructions provided in
the wiring diagram included in the manual.
4
English
DB68-11686A-00_IM_DVM 고효율 Wind Free 4way_AA_EN.indd 4
DB68-11686A-00_IM_DVM 고효율 Wind Free 4way_AA_EN.indd 4
• Always verify that electric connections (cable entry,
section of leads, protections...) are compliant with
the electric specifications and with the instructions
provided in the wiring scheme. Always verify that all
connections comply with the standards applicable to
the installation of air conditioners.
• Devices disconnected from the power supply should be
completely disconnected in the condition of overvoltage
category.
• Be sure not to perform power cable modification,
extension wiring, and multiple wire connection.
– It may cause electric shock or fire due to poor
connection, poor insulation, or current limit override.
– When extension wiring is required due to power line
damage, refer to Step Step 13 Optional:Extending the
power cable in the installation manual.
CAUTION
Make sure that you earth the cables.
• Do not connect the earth wire to the gas pipe, water pipe,
lighting rod or telephone wire. If earthing is not complete,
electric shock or fire may occur.
Install the circuit breaker.
• If the circuit breaker is not installed, electric shock or fire
may occur.
Make sure that the condensed water dripping from the
drain hose runs out properly and safely.
Install the power cable and communication cable of the
indoor and outdoor unit at least 1m away from the electric
appliance.
Install the indoor unit away from lighting apparatus using
the ballast.
• If you use the wireless remote control, reception error
may occur due to the ballast of the lighting apparatus.