Foot POD auto calibration is on by default. It can be turned off in
the sport mode options menu under ACTIVATE, if the foot POD is
paired and is used for the selected sport mode.
For more accurate speed and distance measurements, you can
manually calibrate the foot POD. Perform the calibration on an
accurately measured distance, for instance, on a 400 meter running
track.
To calibrate foot POD with Suunto Ambit3 Run:
1. Attach foot POD to your shoe. For more information, see user
guide for the foot POD you are using.
2. Choose a sport mode (for example Running) in the start menu.
3. Start running at your usual pace. When you cross the starting
line, press [Start Stop] to start the recording.
4. Run a distance of 800–1000 meters (about 0.500–0.700 miles) at
your usual pace (for example two laps on a 400 meter track).
5. Press [Start Stop] when you reach the finish line to pause the
recording.
6. Press [Back Lap] to stop recording. After stopping the exercise,
save the log by pressing [Start Stop]. If you do not want to save
the log, press [Light Lock].
Scroll with [Next] through summary views, until you reach the
distance summary. Adjust the distance shown on the display to
the actual distance you ran with [Start Stop] and [Light Lock].
Confirm with [Next].
7. Confirm the POD calibration by pressing [Start Stop]. Your foot
POD has now been calibrated.