Rheem GF951U Series Installation Instructions Manual page 4

Upflow & downflow/horizontal high efficiency condensing gas furnaces
Table of Contents

Advertisement

WARNING
DUCT LEAKS CAN CREATE AN
UNBALANCED SYSTEM AND
DRAW POLLUTANTS SUCH AS
DIRT, DUST, FUMES AND ODORS
INTO THE HOME CAUSING
PROPERTY DAMAGE. FUMES AND
ODORS FROM TOXIC, VOLATILE
OR FLAMMABLE CHEMICALS, AS
WELL AS AUTOMOBILE EXHAUST
AND CARBON MONOXIDE (CO),
CAN BE DRAWN INTO THE LIVING
SPACE THROUGH LEAKING
DUCTS AND UNBALANCED DUCT
SYSTEMS CAUSING PERSONAL
INJURY OR DEATH (SEE FIGURE
3).
• IF AIR-MOVING EQUIPMENT OR
DUCTWORK IS LOCATED IN
GARAGES OR OFF-GARAGE
STORAGE AREAS - ALL JOINTS,
SEAMS, AND OPENINGS IN THE
EQUIPMENT AND DUCT MUST
BE SEALED TO LIMIT THE
MIGRATION OF TOXIC FUMES
AND ODORS INCLUDING
CARBON MONOXIDE FROM
MIGRATING INTO THE LIVING
SPACE.
• IF AIR-MOVING EQUIPMENT OR
DUCTWORK IS LOCATED IN
SPACES CONTAINING FUEL
BURNING APPLIANCES SUCH
AS WATER HEATERS OR
BOILERS - ALL JOINTS, SEAMS,
AND OPENINGS IN THE
EQUIPMENT AND DUCT MUST
ALSO BE SEALED TO PREVENT
DEPRESSURIZATION OF THE
SPACE AND POSSIBLE
MIGRATION OF COMBUSTION
BYPRODUCTS INCLUDING
CARBON MONOXIDE INTO THE
LIVING SPACE.
NOTICE
IMPROPER INSTALLATION, OR
INSTALLATION NOT MADE IN
ACCORDANCE WITH THE CSA
INTERNATIONAL (CSA)
CERTIFICATION OR THESE
INSTRUCTIONS, CAN RESULT IN
UNSATISFACTORY OPERATION
AND/OR DANGEROUS CONDI-
TIONS AND ARE NOT COVERED
BY THE UNIT WARRANTY.
NOTICE
IN COMPLIANCE WITH
RECOGNIZED CODES, IT IS
RECOMMENDED THAT AN
AUXILIARY DRAIN PAN BE
INSTALLED UNDER ALL
EVAPORATOR COILS OR UNITS
CONTAINING EVAPORATOR
COILS OR GAS FURNACES USED
WITH EVAPORATOR COILS THAT
ARE LOCATED IN ANY AREA OF A
STRUCTURE WHERE DAMAGE TO
THE BUILDING OR BUILDING
CONTENTS MAY OCCUR AS A
RESULT OF AN OVERFLOW OF
THE COIL DRAIN PAN OR A
STOPPAGE IN THE PRIMARY
CONDENSATE DRAIN PIPING.
4
SAFETY INFORMATION
IMPORTANT!
THE COMMONWEALTH OF
MASSACHUSETTS REQUIRES
COMPLIANCE WITH REGULATION
248 CMR 4.00 AND 5.00 FOR
INSTALLATION OF THROUGH-THE-
WALL VENTED GAS APPLIANCES AS
FOLLOWS:
(a) For all side wall horizontally vented
gas fueled equipment installed in every
dwelling, building or structure used in
whole or in part for residential purposes,
including those owned or operated by the
Commonwealth and where the side wall
exhaust vent termination is less than
seven (7) feet above finished grade in
the area of the venting, including but not
limited to decks and porches, the
following requirements shall be satisfied:
1. INSTALLATION OF CARBON
MONOXIDE DETECTORS. At the time
of installation of the side wall horizontal
vented gas fueled equipment, the instal -
ling plumber or gasfitter shall ob serve that
a hard wired carbon mon oxide detector
with an alarm and battery back-up is
installed on the floor level where the gas
equipment is to be installed. In ad dition,
the installing plumber or gasfitter shall
observe that a battery operated or hard
wired carbon mon oxide detector with an
alarm is installed on each addi tional level
of the dwelling, building or structure
served by the side wall hori zon tal vented
gas fueled equipment. It shall be the
responsibility of the property own er to
secure the services of qualified licensed
professionals for the installation of hard
wired carbon monoxide detectors.
a. In the event that the side wall horizon -
tally vented gas fueled equipment is in -
stalled in a crawl space or an attic, the
hard wired carbon monoxide detector
with alarm and battery back-up may be
installed on the next adjacent floor level.
b. In the event that the requirements of
this subdivision can not be met at the
time of completion of installation, the
owner shall have a period of thirty (30)
days to comply with the above require -
ments; provided, however, that during
said thirty (30) day period, a battery
operated carbon monoxide detector with
an alarm shall be installed.
2. APPROVED CARBON MONOXIDE
DETECTORS. Each carbon monoxide
detector is required in accordance with
the above provisions shall comply with
NFPA 720 and be ANSI/UL 2034 listed
and IAS certified.
3.SIGNAGE. A metal or plastic identifica -
tion plate shall be permanently mounted
to the exterior of the building at a mini -
mum height of eight (8) feet above grade
directly in line with the exhaust vent
terminal for the horizontally vented gas
fueled heating appliance or equipment.
The sign shall read, in print size no less
than one-half (1/2) inch in size "GAS
VENT DIRECTLY BELOW. KEEP
CLEAR OF ALL OBSTRUCTIONS".
4. INSPECTION. The state or local
gas inspector of the side wall
horizontally vented gas fueled
equipment shall not approve the
installation unless, upon inspection,
the inspector observes carbon
monoxide detectors and sign age
installed in accordance with the
provisions of 248 CMR 5.08(2)(a) 1
through 4.
(b) EXEMPTIONS: The following
equipment is exempt from 248 CMR
5.08(2)(a) 1 through 4:
1. The equipment listed in Chapter 10
entitled "Equipment Not Required To
Be Vented" in the most current edition
of NFPA 54 as adopted by the Board;
and
2. Product Approved side wall hori -
zon tally vented gas fueled equipment
installed in a room or structure sepa -
rate from the dwelling, building or
structure used in whole or in part for
residential purposes.
(c) MANUFACTURER REQUIRE -
MENTS – GAS EQUIPMENT VENT -
ING SYSTEM PROVIDED. When the
manufacturer of Product Approved
side wall horizontally vented gas
equip ment provides a venting system
design or venting system components
with the equipment, the instructions
provided by the manufacturer for
instal lation of the equipment and the
venting system shall include:
1. Detailed instructions for the instal -
la tion of the venting system design or
the venting system components; and
2. A complete parts list for the venting
system design or venting system.
(d) MANUFACTURER REQUIRE -
MENTS – GAS EQUIPMENT VENT -
ING SYSTEM NOT PROVIDED.
When the manufacturer of a Product
Approved side wall horizontally
vented gas fueled equipment does
not provide the parts for venting the
flue gases, but identified "special
venting systems", the following
requirements shall be satisfied by the
manufacturer:
1. The referenced "special venting
system" instructions shall be included
with the appliance or equipment
installation instructions; and
2. The "special venting systems" shall
be Product Approved by the Board,
and the instructions for that system
shall include a parts list and detailed
installation instructions.
(e) A copy of installation instructions
for all Product Approved side wall
horizontally vented gas fueled equip -
ment, all venting instructions, all parts
lists for venting instructions, and/or all
venting design instructions shall
remain with the appliance or
equipment at the completion of the
installation.