Dynalabs DYN-C-1000-DE Product Manual

2g/4g/8g/10g/20g/40g/50g/100g/200g/500g

Advertisement

Quick Links

Model DYN-C-1000-DE
2g/4g/8g/10g/20g/40g/50g/100g/200g/500g
Product Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DYN-C-1000-DE and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynalabs DYN-C-1000-DE

  • Page 1 Model DYN-C-1000-DE 2g/4g/8g/10g/20g/40g/50g/100g/200g/500g Product Manual...
  • Page 2 All rights reserved. Reproduction or issue to third parties in any form whatsoever is not permitted without written authority from the proprietors. Product Support If at any time you have questions or problems with the DYN-C-1000-DE sensors, please contact a Dynalabs engineer at: Phone: +90 312 266 33 34 (9 a.m.
  • Page 3: Table Of Contents

    All rights reserved. Reproduction or issue to third parties in any form whatsoever is not permitted without written authority from the proprietors. Table of Contents 1) Introduction ..................... 4 2) General Information ..................4 2.1) Unpacking and Inspection ................4 2.2) System Components ...................
  • Page 4: Introduction

    • Custom Connector • Base plate 2) General Information 2.1) Unpacking and Inspection Dynalabs products provide adequate protection for undamaged products to be transported. Document the damages that occur indirectly during the transport and contact the customer representative. 2.2) System Components...
  • Page 5: Specifications

    All rights reserved. Reproduction or issue to third parties in any form whatsoever is not permitted without written authority from the proprietors. 2.3) Specifications Table 1: Specifications datasheet 1002DE 1004DE 1008DE 1010DE 1020DE 1040DE 1050DE 1100DE 1200DE 1500DE Full scale ±2 ±4 ±8...
  • Page 6: Outline Drawing

    Connector (Optional) D-Sub 9 or 15 pin, Lemo, Binder Mounting Adhesive or screw mount Base plate (Optional) Aluminum or Steel 18g (aluminum) Weight (without cable) 43 g (steel) 2.4) Outline Drawing The dimensional properties of DYN-C-1000-DE sensors are given below.
  • Page 7: Operation And Installation

    All rights reserved. Reproduction or issue to third parties in any form whatsoever is not permitted without written authority from the proprietors. 3) Operation and Installation 3.1) General The general sensor connector configuration is given below; Cable Code/Pin Configuration: • Red : V + Power supply voltage +6 to +40 VDC •...
  • Page 8: Declaration Of Conformity

    • MIL-STD-810-H-2019 (Test Methods: 501.7 - High Temperature, 502.7 - Low Temperature, 514.8 - Vibration, 516.8 – Shock) DYNALABS MÜHENDİSLİK SANAYİ TİCARET LİMİTED ŞİRKETİ declares that above mentioned products meet all the requirements of the above mentioned standards and regulations.

This manual is also suitable for:

1000de series1002de1004de1008de1010de1020de ... Show all