8
yes
FAN MODE
Touch repeatedly the MODE key until the fan
appears.
Select the desired air flow by touching the increase
or decrease
C4 buttons.
The air flows available are:
Minimum air flow: when maximum quiet
operation is desired.
Medium air flow: when the noise level needs
to be low but with a good comfort level.
Maximum air flow: for maximum performance.
HEATING MODE (on some models only)
This is ideal in spring and autumn when
outdoor temperatures are not particu-
larly severe. For this mode, the appli-
ance should be prepared in the same
way as for air conditioning, with the air
exhaust hose B4 attached.
To set this mode:
• Touch repeatedly the MODE button
• Touch increase
temperature.
Notes:
In this mode, the air flow is selected automatically by the
no
When using this mode, the air ex-
haust hose B4 does not need to be
attached to the appliance
To correctly set this mode:
until the heating symbol
displayed.
C3 or decrease
C4 buttons to adjust the desired
appliance and cannot be set manually.
When operating in very cold rooms, the appliance defrosts
automatically, momentarily interrupting normal operation. In
this case, "Lt " appears on the display. During this operation, it
is normal for the noise made by the appliance to change.
In this mode, you may have to wait a few minutes before
the appliance starts providing warm air.
In this mode, the fan may operate for short periods, even
though the set temperature has already been reached.
If the display comes on and shows the "HL" alarm, empty
the internal tray following the instructions in the Section
"End of Season operations". Then, touch again the
ton to restore the heating function.
SELECT THE TEMPERATURE SCALE
symbol
OPERATING FROM THE REMOTE CONTROL
C3
INSERTING OR REPLACING THE BATTERIES
Remove the cover on the rear of the remote control;
Insert or replace the batteries with two new LR03 "AAA"
1.5V batteries, inserting them correctly (see the directions
inside the battery compartment);
Replace the cover.
Please note: If the remote control unit is replaced or discarded,
the batteries must be removed and disposed of in accordance
with current legislation as they are harmful to the environment.
Do not mix old and new batteries. Do not mix alkaline, standard
(carbon-zinc) or rechargeable (nickel-cadmium) batteries. Do
not dispose of batteries in fire. Batteries may explode or leak.
If the remote control is not be used for a certain length of time,
remove the batteries.
USING THE REMOTE CONTROL
Point the remote control at the receiver A5 on the air con-
ditioner. The remote control must be no more than 16ft/5
meters away from the appliance (without obstacles be-
tween the remote control and the receiver).
is
The remote control must be handled with care. Do not drop
it or expose it to direct sunlight or sources of heat.
Please note: The remote control can be safely stored in the ap-
propriate compartment A6.
10
The temperature can be displayed
in °C or °F.
To change the temperature unit of
measure touch both the increase/
decrease keys
and
10 seconds.
but-
for about