NIC2-2 · Network ID Camera
• Put the exposure unit in place. Put it in the position according to point 2 in the disassem-
bly instructions. Its position needs to be calibrated later. If point 2 was ignored make
sure that the position is not too far to the left because the carriage may hit the exposure
unit during the opening.
• Now everything is in place. Next step is to adjust the optical switch board. Please refer
to the chapter about the sensor adjustment in the diagnostic chapter.
• Next step is to adjust the position of the exposure unit. How to do this is described in he
Diagnostics chapter.

4.2 Replacing the power supply

!
CAUTION
Remove the mains connection. When working on the
power supply the mains must not be connected.
The power supply is located at the right side of the top cover
• Disconnect the connectors 'A' and 'B'.
• Open the top cover of the power supply by removing the two screws 'C'.
D (x4)
• Remove the four screws 'D' and replace the power supply.
NOTE! The two upper screws holding the power supply are grounding connectors. It is
important that these screws are correctly tightened.
Triacon AB Sweden
C
E
19
Publication no. 201102
Power supply
A
B
C