7. Built in diagnostic software

The Network ID Camera has built in test functions for cassette sensor adjustment and for
testing and adjusting the exposure display. The sensor adjust function is described in the
Sensor adjustment chapter and will not be repeated here.

7.1 Test functions

The test function is entered by entering the Set-up mode and then selecting Test function.
The following window will appear:
Test functions
Exposure display
Opening length
Stop
Press shift-key to enable the following functions.
Adjust
All these function have been put as shifted function keys since they will cause the camera
to operate the motor causing a possible danger for the person operating the camera if the
cover is open. Putting them as shifted function keys means that two keys need to be pressed
to start the operation.
Function keys
The function keys are used as follows:
Stop
Previous
Next
Exit
Adjust
Open
Repeat
Triacon AB Sweden
Pattern: NORMAL
:
114
Previous
Open
Stop the motor.
Select the previous alternative when editing a menu, like the exposure dis-
play pattern selection shown in the picture above.
Select the next alternative when editing a menu.
Close the test function window.
Adjust the exposure display. Pressing this key will cause the camera to open
a cassette inserted and keep it open until the key is pressed once more. The
exposure display will also be switched on. This is very helpful when the pic-
ture projected on the film in the cassette needs to be adjusted. See also the
Adjusting the exposure unit chapter. Note that the opening is performed re-
gardless of the status of the cassette sensors, that is with or without a cas-
sette inserted.
Runs an opening cycle exactly as when making an exposure. NOTE! The
cassette sensors must be activated, that is a cassette must be inserted.
Runs an opening cycle every 2 seconds. NOTE! The cassette sensors must
be activated, that is a cassette must be inserted. The repeat function is ter-
minated either by pressing the EXIT key or by pressing the Repeat key once
more.
POS
:
SPEED
:
RPT CNT:
SENSORS:
Next
Exit
Repeat
Calib