Gas Connections - Napoleon BIB10 Owner's Manual

Hide thumbs Also See for BIB10:
Table of Contents

Advertisement

g
c
aS
onnectionS
This grill must operate with a gas supply pressure of 2.75 kPa (0.39 psi) for propane and 1.00 kPa (0.25 psi) for natural gas. If
the gas supply exceeds these requirements a regulator must be installed upstream of the grill's components. If the gas supply is
lower than the requirements, the unit will be under fired and will not reach the maximum temperatures.
Use a gas pressure regulator and hose supplied by Napoleon; if not included,
use a regulator and hose that meet national and regional codes.
The recommended length of the hose is 0.9 m. The hose must never be
longer than 1.5 m. Check the hose regularly for rips melting or wear. Replace
if needed. The piping up to the grill is the responsibility of the installer.
Note: The hose should be replaced before the expiry date printed on it.
To a House Gas Supply Line
The piping up to the grill is the responsibility of the installer.
• The gas pipe must be sized to supply the MJ/h specified on the rating
plate, based on the length of the piping run.
• If you are installing a side burner, a separate gas line must be branched
off to the unit through a specific opening in that location.
1. A readily accessible manual shut-off valve must be installed upstream
of the unit. A flexible metal connector is included to simplify the
installation. Connect the other end of the connector to the gas piping.
2. Tighten using two wrenches. Do not use thread sealer or pipe dope.
3. Ensure that the connector does not pass through a wall, floor, ceiling or
partition, and is protected from damage.
4. Leak test all joints prior to operating the grill. See "Leak Test".
Note: The gas grill is designed to operate at a test point pressure of 1.00 kPa for natural
gas and must be checked after installation by turning all burners on and measuring at the
regulator outlet test point provided.
• This unit includes an internal regulator which stabilizes the gas pressure and improves
grill performance.
• This regulator cannot be adjusted.
• There is a pressure tap located on the side of the regulator. It can be used by a quali-
fied service person when servicing the grill to determine if the regulator is functioning
properly.
• The screw within the pressure tap must always be kept tight, except when performing a
pressure test on the regulator. This must be done by qualified service personnel only.
WARNING! The supplied regulator with 3/8" SAE 45
connected with rigid pipe, copper tube or approved flexible metal which must comply with AS/NZS 5601.
8
| Getting Started
STAINLESS STEEL
FLEX LINE (INCLUDED)
NATURAL GAS
SHUT OFF VALVE
REGULATOR
(NOT INCLUDED)
(INCLUDED)
O
Flare Inlet Connection (5/8-18 UNF thread) must be
(BIG 44/38/32)
(BIB 10)
(BIB 18/12/10)
Applicable to:
Napoleon.com | BUILT-IN Series
Applicable to:
Applicable to:
(BIB 10)
(BIB 18/12/10)
Applicable to:
(BIB 18/12/10)
(BIB 10)
!

Advertisement