IBM x3950 Problem Determination And Service Manual page 88

Hide thumbs Also See for x3950:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8878 and 8879," on page 109 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
166-201-005
ISMP indicates I2C errors on bus S.
166-201-006
ISMP indicates I2C errors on bus O.
166-201-007
ISMP indicates I2C errors on bus M0.
166-201-008
ISMP indicates I2C errors on bus M1.
72
IBM System x3950 Type 8878 and System x3950 E Type 8879: Problem Determination and Service Guide
Action
1. Reseat the following components:
a. SAS hard disk drive backplane cables
b. I/O board
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. SAS hard disk drive backplane
b. I/O board
1. Reseat the following components:
a. (Trained service technician only) Operator
information panel
b. I/O board
2. Replace the components listed in step 1 one at a
time, in the order shown, restarting the server
each time.
1. Reseat the following components:
a. Memory card
b. I/O board
c. Microprocessor tray
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Memory card
b. I/O board
c. (Trained service technician only)
Microprocessor tray
1. Reseat the following components:
a. Memory card
b. I/O board
c. Microprocessor tray
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Memory card
b. I/O board
c. (Trained service technician only)
Microprocessor tray

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3950 e88788879