IBM x3950 Problem Determination And Service Manual page 31

Hide thumbs Also See for x3950:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8878 and 8879," on page 109 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Beep code
1-3-1
2-1-1
2-1-2
2-1-3
2-1-4
2-2-2
3-1-1
3-1-2
3-1-4
Description
1st 64K RAM test failed.
Secondary DMA register failed.
Primary DMA register failed.
Primary interrupt mask register failed.
Secondary interrupt mask register failed. 1. Reseat the I/O board.
Keyboard controller failed.
Timer tick interrupt failed.
Interval timer channel 2 failed.
Time-of-day clock failed.
Action
1. Reseat the following components:
a. DIMM
b. Memory card
2. Replace the components listed in step 1
one at a time, in the order shown, restarting
the server each time.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the I/O board.
2. Replace the I/O board.
1. Reseat the following components:
a. Battery
b. I/O board
2. Replace the components listed in step 1
one at a time, in the order shown, restarting
the server each time.
Chapter 2. Diagnostics
15