Chapter 1 Installing Windows
(2)
Configuring Flow Control
Flow Control is a feature to stop transmitting frames temporarily by sending a pause frame to the destination
device when the receive buffer is about to run out. When it receives a pause frame, it regulates the transmission.
Configure the Flow Control following the procedure below.
1.
Open the Device Manager.
2.
Expand Network Adapters, and then double-click the name of the network adapter you want to configure.
The properties of the network adapter will be displayed.
3.
Open Advanced tab, click Flow Control to show Value.
4.
The Value can be changed by the down-arrow button.
5.
Click OK, and then restart the system.
The Flow Control setting is now complete.
(3)
Setting up Wake on LAN
-
When using R120h-1E / R120h-2E / T120h onboard network adapters and N8104-172/175/193/194/
195/206/208 with the server, follow the procedure below to set it.
1.
Open the Device Manager.
2.
Expand Network Adapters, and then double-click the name of the network adapter you want to
configure.
The properties of the network adapter will be displayed.
3.
Open Advanced tab, click Enable PME to show Value.
4.
Change the value to Enabled by the down-arrow button.
5.
Click OK, and then restart the system.
Setup is now complete.
-
When not using Wake On LAN on the N8104-208, be sure to follow the procedure below to set it.
1.
Start the system.
2.
Press the <F9> key during the startup process to access System Utility.
Enter the System Configuration, select the LAN controller to set Wake On LAN.
3.
In the case of this product, it is the following name.
OCP Slot 10 Port 1 : Intel(R) Ethernet Network Adapter E810-XXV-2 for OCP 3.0 - xx:xx:xx:xx:xx:xx
OCP Slot 10 Port 2 : Intel(R) Ethernet Network Adapter E810-XXV-2 for OCP 3.0 - xx:xx:xx:xx:xx:xx
4.
Select NIC Configuration, set the Wake On LAN to Disabled.
5.
Select F12: Save and Exit, and select OK or Yes - Save Changes.
When the Reboot button appears, press <Enter> to restart the system.
Setup is now complete.
Tips
The settings of Flow Control of the network adapter should match those of the
destination device. For example, if Flow Control in the destination device is set as
Enabled, that in the network adapter should be set as Enabled.
Installation Guide (Windows Server 2016)
3. Installing Windows Server 2016