Ebyte E70-433T S Series User Manual page 12

Cc1310 433mhz 14/30dbm smd wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
1、2、3
GND
4、5、6、7
NC
8
VCC
9、10
GND
11
PA_EN
12
LNA_EN
13
M2
14
RESET
15
GND
16
AUX
17
TXD
18
TCKC
19
TMSC
20
RXD
21
M1
22
M0
23
GND
24
ANT
This product can achieve Pin compatibility, Pin to Pin replacement
The single-chip microcomputer control PA LNA truth value table is as follows:
Transmitting
Receiving
Sleeping
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2023,
Ground
Ground electrode
Reserved pin
Reserved, to be floated
Voltage :2.2V ~ 3.8V DC
Ground
Ground electrode
Reserved pin
Internal MCU controlled LNA pin, valid in high level, connect to pin 44
Reserved pin
Internal MCU controlled PA pin, valid in high level, connect to pin 45
M2, M1, M0 jointly decide the 8 working modes;
Input
An external 1k protective resistor shall be connected in series when in use.
Input
Reset pin, valid in low level
Ground
Ground electrode
It is used to indicate the operation status of module, for user to wake up the
external MCU, the module outputs low level during self-checking and
output
initialization at power on,
output,
resistor shall be connected in series while using (can be floated)
TTL serial port output connecting to external RXD input pin.
Output
configured as open-drain or push-pull
An external 1k protective resistor shall be connected in series when in use.
Input
JTAG TCKC
Input
JTAG TMSC
TTL serial port input connecting to external TXD pin.
Input
open-drain or high pull
protective resistor shall be connected in series when in use.
M2, M1, M0 jointly decide the 8 working modes;
An external 1k protective resistor shall be connected in series and a 1M
Input
pull-up resistor shall be added when in use.
(Cannot be floated, it can be grounded when not used)
M2, M1, M0 jointly decide the 8 working modes;
An external 1k protective resistor shall be connected in series and a 1M
Input
pull-up resistor shall be added when in use.
(Cannot be floated, it can be grounded when not used)
Ground
Ground electrode
Antenna (50Ω characteristic impedance)
PA_EN
1
0
0
it can be configured as open-drain output or pull-up
please refer to parameter setting par.
input, please refer to Parameter setting.
0
1
0
E70-433TxxSx user manual
An external 1k protective
It can be
input, please refer to Parameter setting.
It can be configured as
An external 1k
LNA_EN
11

Advertisement

Table of Contents
loading

Table of Contents